TROUBLESHOOTING
| warning |
| WARNING |
|
|
| Turn appliance OFF and allow to cool before |
|
|
| servicing. Only a qualified service person |
|
|
| should service and repair the heater. |
|
|
|
|
Note: All troubleshooting items are listed in order of operation.
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | |||
When ignitor button is | 1. Ignitor electrode positioned wrong. | 1 | Replace ignitor. | ||
pressed, there is no spark |
|
|
|
| |
at ODS/pilot. |
|
|
|
| |
2. | Ignitor electrode is broken. | 2. | Replace ignitor. | ||
| |||||
|
|
|
|
| |
| 3. | Ignitor electrode not connected to ignitor | 3. | Reconnect ignitor cable. | |
|
| cable. |
|
| |
|
|
|
|
| |
| 4. | Ignitor cable pinched or wet. Keep ignitor | 4. | Free ignitor cable if pinched by any metal | |
|
| cable dry. |
| or tubing. | |
| 5. | Broken ignitor cable. | 5. | Replace ignitor cable. | |
| 6. | Bad piezo ignitor. | 6. | Replace piezo ignitor. | |
Appliance produces | 1. Appliance burning vapors from paint, hair | 1. | Ventilate room. Stop using odor causing | ||
unwanted odors. |
| spray, glues, etc. |
| products while heater is running. | |
| 2. | Gas leak. | 2. | Locate and correct all leaks. | |
| 3. | Initial burn off | 3. | Ventilate room and turn unit on high until | |
|
|
|
| odor is gone. Odor should be gone after 6 | |
|
|
|
| hours of continuous use. | |
Appliance shuts off during | 1. Not enough fresh air is available for | 1. | Open window and/or door for ventilation. | ||
use. |
| ODS/ pilot to operate. |
|
| |
| 2. | Low line pressure. | 2. | Contact local gas company. | |
| 3. | ODS/pilot is partially clogged. | 3. | Clean ODS/pilot. | |
| 4. | Defective Thermopile. | 4. | Check wire connections. Check output | |
|
|
|
| should be 500 Millivolts across TH/TP and | |
|
|
|
| TP Terminals with ON/OFF switches off. | |
| 5. | Restrictions in incoming air flow. | 5. | Check for bottom riser on glass door, | |
|
|
|
| sunken fireplace, excessive lava rock/ | |
|
|
|
| cinders densely packed against grate. | |
Gas odor even when | 1. Gas leak. | 1. | Locate and correct all leaks. | ||
control knob is in OFF | 2. Control valve defective. | 2. | Replace control valve. | ||
position. |
|
|
|
| |
When ignitor button is | 1. Gas supply turned off or manual shutoff | 1. | Turn on gas supply or open manual shutoff | ||
pressed, there is spark at |
| valve closed. |
| valve. | |
ODS pilot, but no ignition. | 2. Control knob not in PILOT position. | 2. | Turn control knob to PILOT position. | ||
| 3. | Control knob not pressed in while in | 3. | Press in control knob while in PILOT | |
|
| PILOT position. |
| position. | |
| 4. | Air in gas lines when installed. | 4. | Continue holding down control knob. | |
|
|
|
| Repeat igniting operation until air is | |
|
|
|
| removed. | |
| 5. | ODS/pilot is clogged. | 5. | Replace ODS/pilot assembly or get it | |
|
|
|
| serviced. | |
| 6. | Gas regulator setting is not correct. | 6. | Check incoming pressure. Replace gas | |
|
|
|
| regulator. | |
86D0024 |
|
|
| 33 |