Monessen Hearth MJ27PR, MJ27NR operating instructions Please Read and Follow These

Page 37

Massachusetts Residents only:

PLEASE READ AND FOLLOW THESE

Special Requirements

NOTE REGARDING VENTED PRODUCTS

This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachu- setts.

Any residence with a direct vent product must have a CO detector installed in the residence.

Installation of the fireplace or vented gas log in the State of Massachusetts requires the damper to be permanently removed or welded in the fully open position.

In addition, a naturally vented gas log may not be installed in a bedroom or bathroom in the State of Massachusetts. Flex line installation must not exceed 36 inches and must have a T shutoff valve.

NOTE REGARDING VENT FREE PRODUCTS

This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachu- setts.

In addition, vent free products may not be installed in a bedroom or bathroom regardless of size or type in the State of Mas- sachusetts.

Flex line installation must not exceed 36 inches and must have a T shutoff valve.

CARBON MONOXIDE DETECTOR REQUIREMENTS

(2) Revise 10.8.3 by adding the following additional requirements:

(a)For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

1.INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors

a.In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

b.In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be in- stalled.

86D0024

37

Image 37
Contents Natural Gas or Liquid Propane Control Type Millivolt Hi/Low Models MJ27NR, MJ27PRContents Installer Important Safety InformationOwner Gas Code, Ansi Z223.l/NFPA54Utility gas wells. This gas is commonly Never connect unit to private nonKnown as wellhead gas Getting Started What you will need for installationMake sure you have received all parts Product Features and Specifications Codes General Installation InformationAmerican National Standards Institute, Inc National Fire Protection Association, IncBTU / hr = Minimum Hearth Dimension Fireplace and Hearth DimensionsHeight of Restriction Minimum Depth of Fireplace/Firebox Placement in a fireplace with a restrictive barrierSidewall and Ceiling Clearances Clearances and Height RequirementsHeat Resistant Requirements for Safe InstallationMeasurement MJ27 Mantel, Shelf or Other Combustible Projection Heat Resistant Requirements for Safe Installation with Wood12 min Is an example of an unsafe mantel instal Minimum Clearance above Combustible Flooring Floor ClearancePaint by a qualified chimney cleaner Before installing in a solid fuel burningInstalling Vented Applications Fireplace PreparationAssembly procedure Installing Vented ApplicationsPlacing and Securing Appliance Gas Connection Connecting the GASMillivolt Valve Control Figure Checking GAS PressureAte Electrical Wiring MillivoltDo not allow wires Connecting Remote ReceiverBurner To touch grate orLOG Placement Install Log #8 Install Log #4 Place Flickering Bright Embers Place Flickering EmbersANDIRON Installation Andiron and rock installationAssembly Instructions Placing the decorative rockChecking the pilot flame Flame AppearanceOperating Instructions Checking the Burner FlameWhat to do if YOU Smell GAS Operating InstructionsTo Turn OFF GAS to Heater Cleaning and Servicing Operating Instructions / Cleaning and ServicingServicing. Only a qualified service person TroubleshootingShould service and repair the heater Turn appliance OFF and allow to cool beforeGoes out when control Description Qty Replacement partsLogs Replacement Parts listDescription Qty MJ27 Please Read and Follow These 86D0024 Five Year Warranty Lifetime WarrantyBasic Warranty If Warranty Service is NeededMhsc