CDVX Series Direct Vent Gas Fireplace

Do not back fill around snorkel. A clearance of at least 4” (102 mm) must be maintained between the snorkel and the soil.

If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel. Fasten brackets to wall first, then secure to snorkel with self drilling #8 x 1/2 sheet metal screws. It will be necessary to extend vent pipes out as far as protruding wall face. (Fig. 35)

 

Snorkel

Foundation Recess

Wall Screws

 

Recess Brackets

 

Watertight Seal

Sheet Metal

Around Pipe

Screws

 

BG401

Fig. 35 Snorkel installation, recessed foundation.

Vertical Through-the-Roof Applications

This Gas Fireplace has been approved for:

1.Vertical installations up to 40’ (12 m) in height. Up to 10’ (3 m) horizontal vent run can be installed within the vent system using a maximum of three 90° elbows.

2.Up to two 45° elbows may be used within the horizontal run. For each 45° elbow used on the horizontal level the maximum horizontal length must be reduced by 18” (457 mm).

Maximum

Example: Maximum horizontal length

0 x 45° elbows

=

10’ (3 m)

1 x 45° elbows

=

8¹⁄’ (2.6 m)

2 x 45° elbows

=

7’ (2.1 m)

3.A minimum of an 8’ vertical rise.

4.Two sets of 45° elbows offsets within these vertical installations. From 0 to a maximum of 8’ (2.4 m) of vent pipe can be used between elbows. (Fig. 37)

5.7DVCS must be used to support offsets. (Fig. 36) This application will require that you first determine the roof pitch and use the appropriate 7DVSKV (A, B or F). (Refer to Venting Components List, Page 27)

 

 

Max.

 

 

 

8’

 

 

 

(2.4 m)

 

 

45°

 

Typical

 

 

50’

Ceiling

 

 

Support

 

Max.

(15 m)

 

 

Application

 

8’

 

 

(2.4 m)

 

 

 

 

45°

 

 

 

 

Typical Roof

 

 

 

Support Ap-

 

 

 

plication

Typical Offset Installation

FP1021

Fig. 37

Typical vertical roof applications.

 

Minimum

10’ (3 m)

Vertical Through-the-Roof Installation

8’ (2.4 m) / Maximum

40’ (12 m) Vertical Rise

Pipe Straps Every 3’ (914 mm)

CFM148

Fig. 36 Support straps for horizontal runs.

1.

Locate your fireplace.

2.

Plumb to center of the (4”) flue collar from ceiling

 

above and mark position.

3.

Cut opening equal to 9³⁄” x 9³⁄” (240 x 240

 

mm). 10³⁄” x 9³⁄” (264 x 240 mm) when using

 

7TCRVT1320.

4.

Proceed to plumb for additional openings through

 

the roof. In all cases, the opening must provide a

 

minimum of 1 inch clearance to the vent pipe, i.e.,

 

the hole must be at least 9³⁄” x 9³⁄” (240 x 240 mm).

5.

Place fireplace into position.

6.

Place firestop(s) #7DVFS or Attic Insulation Shield

 

#7DVAIS into position and secure. (Fig. 38)

20

20012253

Image 20
Contents Builder Direct Vent Models Table of Contents Installation & Operating Instructions Certified ToRequirements for the Commonwealth of Massachusetts Gas Equipment Venting System not ProvidedFireplace Dimensions Rear Vent Fireplace specifications and framing dimensionsFireplace Dimensions Top Vent 1756 203 mm 435 mm 166 422 mmMantel Chart Locating Your FireplaceClearance to Combustibles MantelsHood Installation HearthFraming and Finishing Final FinishingGas Specifications Gas Line InstallationRemote ON/OFF Switch Gas Inlet and Manifold PressuresGeneral Venting 120V Electrical Hook UpThere must not be any obstruction such as bushes Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationCanadian Installations USA InstallationsGeneral Information Assembling Vent Pipes Flex Vent PipesHow to Use the Vent Graph 36CDVXR VentingExample a Example BRear Wall Installation Twist Lock Pipe StepSide view of final unit location 7TCD45KT Rear Wall Vent ApplicationVertical Sidewall Applications Maximum number of 90 elbows is threeVertical Sidewall Installation Maximum number of elbowsBelow Grade Installation 7TDVSNORKVertical Through-the-Roof Installation Vertical Through-the-Roof ApplicationsEnlarged ends of the vent section always face down. Fig Place firestop spacers and secure36CDVXT Vertical Venting Cdvxt Top Vent BaffleVertical Sidewall Installations Always install horizontal venting on a level plane Vertical height requirementBelow Grade Installations Apply high temperature sealant to collars or termina- tionsMax 3m Min 610 mm Venting Components Glass Cleaning Window Frame Assembly RemovalOperating Instructions Glass InformationFlame & Temperature Adjustment Flame CharacteristicsLogs RN/RP & EN/EP ModelsLighting and Operating Instructions To Turn Off Gas to FireplaceValve in the on position Lighting InstructionsTurning Off the Gas to the Appliance Troubleshooting the Gas Control System Fuel Conversion Instructions Pilot ConversionReassembly Testing for LeaksPilot Flame Adjustment Burner and Burner Compartment MaintenanceCleaning the Standing Pilot Control System Description 6a,b 14a,bCdvx Fuel Conversion KitsOptional Accessories Available Wiring InstructionsRemote Controls Fan KitsCdvx Series Direct Vent Gas Fireplace Cdvx Series Direct Vent Gas Fireplace Cdvx Series Direct Vent Gas Fireplace Basic Warranty Lifetime WarrantyFive Year Warranty Efficiency Ratings Fan-OFF Fan-ON

36CDVXTRN specifications

The Monessen Hearth 36CDVXTRN is a distinguished choice in the world of gas fireplaces, seamlessly blending aesthetics with cutting-edge technology. Designed to provide ample warmth while enhancing the ambiance of any room, this unit embodies the perfect fusion of form and function.

At the heart of the Monessen Hearth 36CDVXTRN is its impressive 36-inch width, providing a generous viewing area for the mesmerizing flames. The glass front offers an unobstructed view, creating a stunning focal point in any living space. With a contemporary design and realistic log set, this fireplace captures the essence of a traditional wood-burning fire without the hassle of logs or ash cleanup.

One of the standout features of the 36CDVXTRN is its advanced burner technology. The fireplace utilizes a dual burner system to create a realistic flame that rises and dances, mimicking the natural motion of a wood fire. This not only adds to the aesthetic appeal but also ensures a consistent and efficient heat output. The unit boasts an exceptional heat output of up to 33,000 BTUs, making it suitable for heating larger areas while maintaining efficiency.

The Monessen Hearth 36CDVXTRN is engineered with user convenience in mind. It comes equipped with a remote control, allowing users to easily adjust settings from the comfort of their seat. The IntelliFire® ignition system adds another layer of convenience, offering a reliable and efficient ignition process. This innovative technology ensures safe operation and quick lighting, eliminating the need for matches or lighters.

Safety is a top priority with the Monessen Hearth 36CDVXTRN. The fireplace includes a sealed combustion chamber, preventing any harmful gases from entering the home. Additionally, the unit features a standard safety shut-off, which automatically turns off the gas supply in case of a malfunction, providing peace of mind for families.

Installation is straightforward with the Monessen Hearth 36CDVXTRN, as it is designed for either vented or vent-free configurations. This versatility allows homeowners to select the best option for their specific needs and preferences. Furthermore, the unit is compatible with various decorative options, from traditional mantels to modern finishes, allowing for complete customization to fit any interior style.

Overall, the Monessen Hearth 36CDVXTRN stands out as a premium gas fireplace solution, offering exceptional heat output, user-friendly features, and an elegant design. Its blend of modern technology and traditional aesthetics makes it an ideal choice for those looking to enhance their living space while enjoying the comforts of a captivating fire. Whether used for warmth or as a centerpiece of relaxation, the Monessen Hearth 36CDVXTRN is a testament to quality and sophistication in home heating solutions.