Monessen Hearth 36CDVXTRN Requirements for the Commonwealth of Massachusetts

Page 4

CDVX Series Direct Vent Gas Fireplace

Installation & Operating Instructions

Requirements for the Commonwealth of Massachusetts

All gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber.

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

Installation of Carbon Monoxide Detectors

At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.

In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days

to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

Approved Carbon Monoxide Detectors

Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and ANSI/UL 2034 listed and IAS certified.

Signage

A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW, KEEP

CLEAR OF ALL OBSTRUCTIONS”.

Inspection

The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

Exemptions

The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and

Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.

MANUFACTURER REQUIREMENTS

Gas Equipment Venting System Provided

When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

Detailed instructions for the installation of the venting system design or the venting system components; and

A complete parts list for the venting system design or venting system.

Gas Equipment Venting System NOT Provided

When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems”, the following requirements shall be satisfied by the manufacturer:

The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and

The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.

A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

20012253

Image 4
Contents Builder Direct Vent Models Table of Contents Installation & Operating Instructions Certified ToRequirements for the Commonwealth of Massachusetts Gas Equipment Venting System not ProvidedFireplace Dimensions Rear Vent Fireplace specifications and framing dimensionsFireplace Dimensions Top Vent 1756 203 mm 435 mm 166 422 mmMantel Chart Locating Your FireplaceClearance to Combustibles MantelsHood Installation HearthFraming and Finishing Final FinishingGas Specifications Gas Line InstallationRemote ON/OFF Switch Gas Inlet and Manifold PressuresGeneral Venting 120V Electrical Hook UpThere must not be any obstruction such as bushes Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationCanadian Installations USA InstallationsGeneral Information Assembling Vent Pipes Flex Vent PipesHow to Use the Vent Graph 36CDVXR VentingExample a Example BRear Wall Installation Twist Lock Pipe StepSide view of final unit location 7TCD45KT Rear Wall Vent ApplicationVertical Sidewall Applications Maximum number of 90 elbows is threeVertical Sidewall Installation Maximum number of elbowsBelow Grade Installation 7TDVSNORKVertical Through-the-Roof Installation Vertical Through-the-Roof ApplicationsEnlarged ends of the vent section always face down. Fig Place firestop spacers and secure36CDVXT Vertical Venting Cdvxt Top Vent BaffleVertical Sidewall Installations Always install horizontal venting on a level plane Vertical height requirementBelow Grade Installations Apply high temperature sealant to collars or termina- tionsMax 3m Min 610 mm Venting Components Glass Cleaning Window Frame Assembly RemovalOperating Instructions Glass InformationFlame & Temperature Adjustment Flame CharacteristicsLogs RN/RP & EN/EP ModelsLighting and Operating Instructions To Turn Off Gas to FireplaceTurning Off the Gas to the Appliance Lighting InstructionsValve in the on position Troubleshooting the Gas Control System Fuel Conversion Instructions Pilot ConversionPilot Flame Adjustment Testing for LeaksReassembly Cleaning the Standing Pilot Control System MaintenanceBurner and Burner Compartment Description 6a,b 14a,bCdvx Fuel Conversion KitsOptional Accessories Available Wiring InstructionsRemote Controls Fan KitsCdvx Series Direct Vent Gas Fireplace Cdvx Series Direct Vent Gas Fireplace Cdvx Series Direct Vent Gas Fireplace Five Year Warranty Lifetime WarrantyBasic Warranty Efficiency Ratings Fan-OFF Fan-ON

36CDVXTRN specifications

The Monessen Hearth 36CDVXTRN is a distinguished choice in the world of gas fireplaces, seamlessly blending aesthetics with cutting-edge technology. Designed to provide ample warmth while enhancing the ambiance of any room, this unit embodies the perfect fusion of form and function.

At the heart of the Monessen Hearth 36CDVXTRN is its impressive 36-inch width, providing a generous viewing area for the mesmerizing flames. The glass front offers an unobstructed view, creating a stunning focal point in any living space. With a contemporary design and realistic log set, this fireplace captures the essence of a traditional wood-burning fire without the hassle of logs or ash cleanup.

One of the standout features of the 36CDVXTRN is its advanced burner technology. The fireplace utilizes a dual burner system to create a realistic flame that rises and dances, mimicking the natural motion of a wood fire. This not only adds to the aesthetic appeal but also ensures a consistent and efficient heat output. The unit boasts an exceptional heat output of up to 33,000 BTUs, making it suitable for heating larger areas while maintaining efficiency.

The Monessen Hearth 36CDVXTRN is engineered with user convenience in mind. It comes equipped with a remote control, allowing users to easily adjust settings from the comfort of their seat. The IntelliFire® ignition system adds another layer of convenience, offering a reliable and efficient ignition process. This innovative technology ensures safe operation and quick lighting, eliminating the need for matches or lighters.

Safety is a top priority with the Monessen Hearth 36CDVXTRN. The fireplace includes a sealed combustion chamber, preventing any harmful gases from entering the home. Additionally, the unit features a standard safety shut-off, which automatically turns off the gas supply in case of a malfunction, providing peace of mind for families.

Installation is straightforward with the Monessen Hearth 36CDVXTRN, as it is designed for either vented or vent-free configurations. This versatility allows homeowners to select the best option for their specific needs and preferences. Furthermore, the unit is compatible with various decorative options, from traditional mantels to modern finishes, allowing for complete customization to fit any interior style.

Overall, the Monessen Hearth 36CDVXTRN stands out as a premium gas fireplace solution, offering exceptional heat output, user-friendly features, and an elegant design. Its blend of modern technology and traditional aesthetics makes it an ideal choice for those looking to enhance their living space while enjoying the comforts of a captivating fire. Whether used for warmth or as a centerpiece of relaxation, the Monessen Hearth 36CDVXTRN is a testament to quality and sophistication in home heating solutions.