Monessen Hearth 36CDVXTRN Always install horizontal venting on a level plane

Page 24

CDVX Series Direct Vent Gas Fireplace

Example:

 

 

 

 

Elbow 1

=

90°

 

 

Elbow 2

=

45°

4

 

Elbow 3

=

45°

 

 

Elbow 4

=

90°

 

Total angular variation

=

270°

 

 

1 + 2 + 3 + 4 = 270°

 

 

 

 

 

3

 

1

 

2

 

 

 

 

 

 

 

 

 

FP1239

Fig. 48

Maximum number of elbow degrees.

STEP 2

Place fireplace into position. (Fig. 49) Measure the verti- cal height (X) required from the base of the flue collars to the center of the wall opening.

STEP 3

Attach appropriate venting component(s) to the fire- place with three (3) screws. (Fig. 50) Follow with the installation of the inner and outer elbow. Again secure joints with three (3) sheet metal screws.

X

FP1240

Fig. 49 Vertical height requirement.

STEP 4

Measure the horizontal length requirement including a 2” (51 mm) overlap, ie from the elbow to the outside wall face plus 2” (51 mm) (or the distance required if installing a second 90° elbow). (Fig. 50)

X

FP1241

Fig. 50 Horizontal length requirement.

Always install horizontal venting on a level plane.

STEP 5

Use appropriate length of pipe sections - telescopic or fixed - and install the horizontal vent sections. The sec- tions which go through the wall are packaged with the starter kit, and can be cut to suit if necessary. (Fig. 48)

Sealing the gaps between the vent pipe and firestop with high temperature sealant will restrict cold air being drawn in around fireplace.

STEP 6

Guide the vent terminations 4” and 7” collars into their respective vent pipes. Double check that the vent pipes overlap the collars by 2” (51 mm). Secure the termina- tion to the wall with screws provided and caulk around the wall plate to weatherproof. (Fig. 52) As an alterna- tive to screwing the termination directly to the wall you may also use expanding plugs or an approved exterior construction adhesive. You may also attach the termi- nation with screws through the inner body into the 4” (102 mm) vent pipe however for this method you must extend the 4” (102 mm) pipe approximately 6” (152 mm) beyond the outer face of the wall.

Support horizontal pipes every 3’ (914 mm) with metal pipe straps. Make sure the horizontal vent pipe is in- stalled on a level horizontal plane.

24

20012253

Image 24
Contents Builder Direct Vent Models Table of Contents Installation & Operating Instructions Certified ToRequirements for the Commonwealth of Massachusetts Gas Equipment Venting System not ProvidedFireplace Dimensions Rear Vent Fireplace specifications and framing dimensionsFireplace Dimensions Top Vent 1756 203 mm 435 mm 166 422 mmMantel Chart Locating Your FireplaceClearance to Combustibles MantelsHood Installation HearthFraming and Finishing Final FinishingGas Specifications Gas Line InstallationRemote ON/OFF Switch Gas Inlet and Manifold PressuresGeneral Venting 120V Electrical Hook UpThere must not be any obstruction such as bushes Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationCanadian Installations USA InstallationsGeneral Information Assembling Vent Pipes Flex Vent PipesHow to Use the Vent Graph 36CDVXR VentingExample a Example BRear Wall Installation Twist Lock Pipe StepSide view of final unit location 7TCD45KT Rear Wall Vent ApplicationVertical Sidewall Applications Maximum number of 90 elbows is threeVertical Sidewall Installation Maximum number of elbowsBelow Grade Installation 7TDVSNORKVertical Through-the-Roof Installation Vertical Through-the-Roof ApplicationsEnlarged ends of the vent section always face down. Fig Place firestop spacers and secure36CDVXT Vertical Venting Cdvxt Top Vent BaffleVertical Sidewall Installations Always install horizontal venting on a level plane Vertical height requirementBelow Grade Installations Apply high temperature sealant to collars or termina- tionsMax 3m Min 610 mm Venting Components Glass Cleaning Window Frame Assembly RemovalOperating Instructions Glass InformationFlame & Temperature Adjustment Flame CharacteristicsLogs RN/RP & EN/EP ModelsLighting and Operating Instructions To Turn Off Gas to FireplaceLighting Instructions Turning Off the Gas to the ApplianceValve in the on position Troubleshooting the Gas Control System Fuel Conversion Instructions Pilot ConversionTesting for Leaks Pilot Flame AdjustmentReassembly Maintenance Cleaning the Standing Pilot Control SystemBurner and Burner Compartment Description 6a,b 14a,bCdvx Fuel Conversion KitsOptional Accessories Available Wiring InstructionsRemote Controls Fan KitsCdvx Series Direct Vent Gas Fireplace Cdvx Series Direct Vent Gas Fireplace Cdvx Series Direct Vent Gas Fireplace Lifetime Warranty Five Year WarrantyBasic Warranty Efficiency Ratings Fan-OFF Fan-ON

36CDVXTRN specifications

The Monessen Hearth 36CDVXTRN is a distinguished choice in the world of gas fireplaces, seamlessly blending aesthetics with cutting-edge technology. Designed to provide ample warmth while enhancing the ambiance of any room, this unit embodies the perfect fusion of form and function.

At the heart of the Monessen Hearth 36CDVXTRN is its impressive 36-inch width, providing a generous viewing area for the mesmerizing flames. The glass front offers an unobstructed view, creating a stunning focal point in any living space. With a contemporary design and realistic log set, this fireplace captures the essence of a traditional wood-burning fire without the hassle of logs or ash cleanup.

One of the standout features of the 36CDVXTRN is its advanced burner technology. The fireplace utilizes a dual burner system to create a realistic flame that rises and dances, mimicking the natural motion of a wood fire. This not only adds to the aesthetic appeal but also ensures a consistent and efficient heat output. The unit boasts an exceptional heat output of up to 33,000 BTUs, making it suitable for heating larger areas while maintaining efficiency.

The Monessen Hearth 36CDVXTRN is engineered with user convenience in mind. It comes equipped with a remote control, allowing users to easily adjust settings from the comfort of their seat. The IntelliFire® ignition system adds another layer of convenience, offering a reliable and efficient ignition process. This innovative technology ensures safe operation and quick lighting, eliminating the need for matches or lighters.

Safety is a top priority with the Monessen Hearth 36CDVXTRN. The fireplace includes a sealed combustion chamber, preventing any harmful gases from entering the home. Additionally, the unit features a standard safety shut-off, which automatically turns off the gas supply in case of a malfunction, providing peace of mind for families.

Installation is straightforward with the Monessen Hearth 36CDVXTRN, as it is designed for either vented or vent-free configurations. This versatility allows homeowners to select the best option for their specific needs and preferences. Furthermore, the unit is compatible with various decorative options, from traditional mantels to modern finishes, allowing for complete customization to fit any interior style.

Overall, the Monessen Hearth 36CDVXTRN stands out as a premium gas fireplace solution, offering exceptional heat output, user-friendly features, and an elegant design. Its blend of modern technology and traditional aesthetics makes it an ideal choice for those looking to enhance their living space while enjoying the comforts of a captivating fire. Whether used for warmth or as a centerpiece of relaxation, the Monessen Hearth 36CDVXTRN is a testament to quality and sophistication in home heating solutions.