Monessen Hearth 36CDVXTRN Installation & Operating Instructions, Certified To

Page 3

CDVX Series Direct Vent Gas Fireplace

Installation & Operating Instructions

This gas appliance should be installed by a qualified installer, preferably NFI or WETT (Canada) certified, in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment. For USA Installations follow local codes and/or the current National Fuel Gas Code. ANSI Z223.1/NFPA 54.

FOR SAFE INSTALLATION AND OPERATION PLEASE NOTE THE FOLLOWING:

1.This fireplace gives off high temperatures and should be located out of high traffic areas and away from furniture and draperies.

2.Children and adults should be alerted to the hazards of high surface temperatures of this fireplace and should stay away to avoid burns or ignition of clothing.

3.CAUTION: Due to high glass surface temperature chil- dren should be carefully supervised when in the same room as fireplace.

7!2.).'

(/4/',!33 7),,

#!53%5"52.3

$/ ./4 4/5#( ',!33

5.4),4#//,%$

.%6%2 !,,/77#(),$2%.

4/ 4/5#( ',!33

4.Under no circumstances should this fireplace be modified. Parts removed for servicing should be replaced prior to operating this fireplace again.

5.Installation and any repairs to this fireplace must be performed by a qualified installer, service agency or gas supplier. A professional service person should be contacted to inspect this fireplace annually. Make it a practice to have all of your gas fireplaces checked annually. More frequent cleaning may be required due to excess lint and dust from carpeting, bedding material, etc.

6.Control compartments, burners and air passages in this fireplace should be kept clean and free of dust and lint. Make sure the gas valve and pilot light are turned off before you attempt to clean this fireplace.

7.The venting system (chimney) of this fireplace should be checked at least once a year and if needed your venting system should be cleaned.

8.Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor and liquids. This fireplace should not be used as a drying rack for cloth- ing, nor should Christmas stockings or decorations be hung on or around the fireplace.

9.Under no circumstances should any solid fuels (wood, coal, paper or cardboard etc.) be used in this fireplace.

10.The flow of combustion and ventilation air must not be obstructed in any way.

11.When fireplace is installed directly on carpeting, vinyl tile or any combustible material other than wood, the fireplace must be installed on a metal or wood panel extending the full width and depth of the fireplace.

12.This fireplace requires adequate ventilation and combustion air to operate properly.

13.This fireplace must not be connected to a chimney flue serving a separate solid fuel burning fireplace.

14.When the fireplace is not in use it is recommended that the gas valve be left in the OFF position.

15.These units have been approved for bedroom use.

36CDVXR / 36CDVXT

Certified To

ANSI Z21.88b-2008 / CSA 2.33b-2008

Vented Gas Fireplace Heaters

WARNING: Check with your electronics manufacturer before installing a television or other electronic de- vice above this fireplace.

This appliance may be installed in an aftermarket permanently located, manufactured home or mobile home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

The CDVXR has been approved for mobile home installations.

IMPORTANT:

PLEASE REVIEW THE FOLLOWING CAREFULLY Remove any plastic from trim parts before turning the fireplace ON.

It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine.

It is not unusual for your gas fireplace to give off some odor the first time it is burned. This is due to the curing of the paint and any undetected oil from the manufacturing process.

Please ensure that your room is well ventilated - open all windows.

It is recommended that you burn your fireplace for at least ten (10) hours the first time you use it. If the optional fan kit has been installed, place the fan switch in the “OFF” position during this time.

Proposition 65 Warning: Fuels used in gas, wood- burning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm.

California Health & Safety Code Sec. 25249.6

20012253

Image 3
Contents Builder Direct Vent Models Table of Contents Certified To Installation & Operating InstructionsGas Equipment Venting System not Provided Requirements for the Commonwealth of MassachusettsFireplace specifications and framing dimensions Fireplace Dimensions Rear Vent1756 203 mm 435 mm 166 422 mm Fireplace Dimensions Top VentMantels Mantel ChartLocating Your Fireplace Clearance to CombustiblesFinal Finishing Hood InstallationHearth Framing and FinishingGas Inlet and Manifold Pressures Gas SpecificationsGas Line Installation Remote ON/OFF SwitchLocation of Vent Termination General Venting120V Electrical Hook Up There must not be any obstruction such as bushesGeneral Venting Information Termination Location Canadian Installations1 US Installations2Flex Vent Pipes Canadian InstallationsUSA Installations General Information Assembling Vent PipesExample B How to Use the Vent Graph36CDVXR Venting Example aStep Rear Wall Installation Twist Lock PipeSide view of final unit location Rear Wall Vent Application 7TCD45KTMaximum number of 90 elbows is three Vertical Sidewall ApplicationsMaximum number of elbows Vertical Sidewall Installation7TDVSNORK Below Grade InstallationVertical Through-the-Roof Applications Vertical Through-the-Roof InstallationPlace firestop spacers and secure Enlarged ends of the vent section always face down. FigCdvxt Top Vent Baffle 36CDVXT Vertical VentingVertical Sidewall Installations Vertical height requirement Always install horizontal venting on a level planeApply high temperature sealant to collars or termina- tions Below Grade InstallationsMax 3m Min 610 mm Venting Components Glass Information Glass CleaningWindow Frame Assembly Removal Operating InstructionsRN/RP & EN/EP Models Flame & Temperature AdjustmentFlame Characteristics LogsTo Turn Off Gas to Fireplace Lighting and Operating InstructionsLighting Instructions Turning Off the Gas to the ApplianceValve in the on position Troubleshooting the Gas Control System Pilot Conversion Fuel Conversion InstructionsTesting for Leaks Pilot Flame AdjustmentReassembly Maintenance Cleaning the Standing Pilot Control SystemBurner and Burner Compartment 6a,b 14a,b DescriptionFuel Conversion Kits CdvxFan Kits Optional Accessories AvailableWiring Instructions Remote ControlsCdvx Series Direct Vent Gas Fireplace Cdvx Series Direct Vent Gas Fireplace Cdvx Series Direct Vent Gas Fireplace Lifetime Warranty Five Year WarrantyBasic Warranty Fan-OFF Fan-ON Efficiency Ratings

36CDVXTRN specifications

The Monessen Hearth 36CDVXTRN is a distinguished choice in the world of gas fireplaces, seamlessly blending aesthetics with cutting-edge technology. Designed to provide ample warmth while enhancing the ambiance of any room, this unit embodies the perfect fusion of form and function.

At the heart of the Monessen Hearth 36CDVXTRN is its impressive 36-inch width, providing a generous viewing area for the mesmerizing flames. The glass front offers an unobstructed view, creating a stunning focal point in any living space. With a contemporary design and realistic log set, this fireplace captures the essence of a traditional wood-burning fire without the hassle of logs or ash cleanup.

One of the standout features of the 36CDVXTRN is its advanced burner technology. The fireplace utilizes a dual burner system to create a realistic flame that rises and dances, mimicking the natural motion of a wood fire. This not only adds to the aesthetic appeal but also ensures a consistent and efficient heat output. The unit boasts an exceptional heat output of up to 33,000 BTUs, making it suitable for heating larger areas while maintaining efficiency.

The Monessen Hearth 36CDVXTRN is engineered with user convenience in mind. It comes equipped with a remote control, allowing users to easily adjust settings from the comfort of their seat. The IntelliFire® ignition system adds another layer of convenience, offering a reliable and efficient ignition process. This innovative technology ensures safe operation and quick lighting, eliminating the need for matches or lighters.

Safety is a top priority with the Monessen Hearth 36CDVXTRN. The fireplace includes a sealed combustion chamber, preventing any harmful gases from entering the home. Additionally, the unit features a standard safety shut-off, which automatically turns off the gas supply in case of a malfunction, providing peace of mind for families.

Installation is straightforward with the Monessen Hearth 36CDVXTRN, as it is designed for either vented or vent-free configurations. This versatility allows homeowners to select the best option for their specific needs and preferences. Furthermore, the unit is compatible with various decorative options, from traditional mantels to modern finishes, allowing for complete customization to fit any interior style.

Overall, the Monessen Hearth 36CDVXTRN stands out as a premium gas fireplace solution, offering exceptional heat output, user-friendly features, and an elegant design. Its blend of modern technology and traditional aesthetics makes it an ideal choice for those looking to enhance their living space while enjoying the comforts of a captivating fire. Whether used for warmth or as a centerpiece of relaxation, the Monessen Hearth 36CDVXTRN is a testament to quality and sophistication in home heating solutions.