Using the Reset Switch

Table 4-2 Troubleshooting Checklist (continued)

Problem

Possible Cause

Recommended Action

 

 

 

Port(s) goes into

Loop condition detected.

Verify that Spanning Tree is enabled. Refer to the

standby for no

 

SecureStack B3 Configuration Guide for the instructions to

apparent reason.

 

set the type of STA.

 

 

Review the network design and delete unnecessary loops.

 

 

If the problem continues, contact Enterasys Networks for

 

 

technical support.

 

 

 

User parameters

Clear NVRAM was set using

Reenter the lost parameters as necessary. Refer to the

(IP address, device

CLI commands.

SecureStack B3 Configuration Guide for the instructions to

and module name,

 

configure the switch using CLI commands.

etc.) were lost

 

If the problem continues, contact Enterasys Networks for

when the switch

 

 

technical support.

power was cycled.

 

 

 

 

 

 

Using the Reset Switch

If you forget the switch login password, use the Reset switch to reset the login password to the default password, as described in the following procedure.

Figure 4-3 Reset Switch

À

1Reset switch

4-8 Troubleshooting