Connecting to the Network
2.Insert the MT‐RJ cable connector into the MT‐RJ connector until it clicks into place.
Note: To remove the
Figure 3-18 Cable Connection to MT-RJ Multimode Fiber-Optic Connectors
1 | 3 | Release tab | |
2 | 4 | Link/Activity LED |
3.Plug the other end of the cable into the appropriate port on the other device. Some cables may be terminated at the other end with two separate connectors, one for each fiber‐optic strand. In this case, ensure that the transmit fiber‐optic strand is connected to the receive port and the receive fiber‐optic strand to the transmit port.
4.Verify that a link exists by checking that the port Link/Activity LED is on (blinking green or solid green). If the Link/Activity LED is off, perform the following steps until it is on:
a.Verify that the device at the other end of the segment is ON and connected to the segment.
b.If there are separate fiber‐optic connections on the other device, check the crossover of the cables. Swap the cable connections if necessary.
c.Check that the fiber‐optic connection meets the dB loss and cable specifications outlined in the Cabling Guide for multimode cabling. To obtain this document, refer to “Related Documents” on page xvi.
SecureStack B3 Installation Guide