Enterasys Networks B3G124-24P Lanview LED Diagnostic Indications, Color State Recommended Action

Models: B3G124-48P B3G124-24P

1 80
Download 80 pages 32.81 Kb
Page 64
Image 64

Using LANVIEW

Table 4-1 LANVIEW LED Diagnostic Indications

LED

Color

State

Recommended Action

 

 

 

 

CPU

Off

Power disconnected.

If the LED remains off after connecting

 

 

 

AC power or DC power from an RPS,

 

 

 

check the following:

 

 

 

1. Make sure there is power at the

 

 

 

power source (AC source and RPS

 

 

 

if applicable).

 

 

 

2. Replace the power cord with a

 

 

 

known good one or check the

 

 

 

continuity of the power cord.

 

 

 

3. If the switch still does not power up,

 

 

 

the system may have a fatal error.

 

 

 

Contact Enterasys Networks for

 

 

 

technical support.

 

 

 

 

 

Red

Solid. Boot-up failed.

If the LED remains red for several

 

 

 

minutes, the system may have a fatal

 

 

 

error. Contact Enterasys Networks for

 

 

 

technical support.

 

 

 

 

 

Amber

Solid. Diagnostics are running.

If the LED remains amber for more than

 

 

 

several minutes, contact

 

 

 

Enterasys Networks for technical

 

 

 

support.

 

 

 

 

 

 

Blinking. Code image is being downloaded.

None.

 

 

 

 

 

Green

Solid. System is fully functional.

None.

 

 

 

 

 

 

Blinking. Boot-up in process.

None.

 

 

 

 

DOWN

Off

No valid connection to switch stack up

1. Make sure the switch connected to

 

 

connector.

the stack up connector is powered

 

 

 

on.

 

 

 

2. Replace cable with a known good

 

 

 

one.

 

 

 

3. If the problem still exists, contact

 

 

 

Enterasys Networks for technical

 

 

 

support.

 

 

 

 

 

Green

Solid. Valid connection to switch stack up

None.

 

 

connector.

 

 

 

Blinking. Information is being transferred

 

 

 

through the high-speed stacking cable.

 

 

 

 

 

4-4 Troubleshooting

Page 64