Using LANVIEW
4-6 Troubleshooting
Link/
Activity
(RJ45 PoE
ports)
Off 1. No link.
2. No activity or port in standby.
3. The port is deactivated because the
Mini-GBIC port with the same port number
is linked.
None.
None.
None.
Green Solid. Port is linked, but the interface is not
receiving any traffic. PoE power is available.
None.
Blinking. Port is linked and traffic is being
received or transmitted by the interface. PoE
power is available.
None.
Amber Solid. Port is linked, but traffic is not being
received or transmitted by the interface. PoE
power has failed.
PoE power may have been deactivated
because of excessive power requirement or
deactivated by configuration.
Power Supply failed.
1. Check the attached powered device
to see if it is defective.
2. Internal power supply failed, contact
EnterasysNetworks for technical
support.
Blinking. Port is linked and traffic is being
received or transmitted by the interface. PoE
power has failed.
PoE power may have been deactivated
because of excessive power requirement or
deactivated by configuration.
Power supply failed.
1. Check the attached powered device
to see if it is defective.
2. Internal power supply failed, contact
EnterasysNetworks for technical
support.
Link/
Activity
(MGBIC
ports)
Off 1. No link.
2. No activity or port in standby.
None.
None.
Green Solid. Port is linked, but the interface is not
receiving any traffic.
None.
Blinking. Port is linked and traffic is being
received or transmitted by the interface.
None.
Table 4-1 LANVIEW LED Diagnostic Indications (continued)
LED Color State Recommended Action