Table 4-1 LANVIEW LED Diagnostic Indications (continued)

 

 

 

 

 

 

LED

Color

State

Recommended Action

 

 

 

 

 

UP

Off

No valid connection to switch stack down

1.

Make sure the switch connected to

 

 

connector.

 

the stack down connector is

 

 

 

 

powered on.

 

 

 

2.

Replace cable with a known good

 

 

 

 

one.

 

 

 

3.

If the problem still exists, contact

 

 

 

 

Enterasys Networks for technical

 

 

 

 

support.

 

 

 

 

 

Green

Solid. Valid connection to switch stack down

None.

 

 

connector.

 

 

 

 

Blinking. Information is being transferred

 

 

 

 

through the high-speed stacking cable.

 

 

 

 

 

 

Manager

Off

Switch is operating as a Member in the stack.

None.

 

 

 

 

 

Green

Solid. Switch is operating as the Manager of

None.

 

 

the stack.

 

 

 

 

 

 

RPS

Off

Connected C2RPS-POE supply not in use.

None.

 

 

Internal power supply failed.

If a C2RPS-POE RPS is connected to

 

 

 

the switch, it should be providing

 

 

 

power. To determine if there is a

 

 

 

problem, perform the following:

 

 

 

1.

Ensure the RPS is powered on.

 

 

 

2.

Ensure that the AC power cord to

 

 

 

 

the RPS is plugged in correctly and

 

 

 

 

that there is power at the AC power

 

 

 

 

source.

 

 

 

3.

Replace the power cord with a

 

 

 

 

known good one.

 

 

 

4.

Ensure the DC power cable

 

 

 

 

(C2RPS-POE) from the RPS to the

 

 

 

 

switch is plugged in correctly.

 

 

 

5.

If the problem persists, contact

 

 

 

 

Enterasys Networks for technical

 

 

 

 

support.

 

 

 

 

 

Amber

Solid. The switch internal power supply failed,

None.

 

 

and the RPS is providing the proper power to

 

 

 

 

the switch.

 

 

 

 

 

 

 

SecureStack B3 Installation Guide 4-5