Napoleon Fireplaces BGD40-N, BGD40-P manual Peninsula Installation Procedure, Venting, Framing

Page 14

14

PENINSULA INSTALLATION PROCEDURE

VENTING

Refer to pages 6-13. All venting must have a minimum clear- ance of 2" to combustible material on the top and 1" to the

sides and bottom.

FRAMING

See Page 18 for additional framing dimensions. NOTE: In order to avoid the possibility of exposed insula- tion or vapor barrier coming in contact with the

replace body, it is recommended that the walls of the

replace enclosure be “fi nished” (ie: drywall/sheetrock), as you would fi nish any other outside wall of a home. This will ensure that clearance to combustibles is maintained within the cavity.

It is best to frame your fireplace after it is positioned and the vent system is installed. Use 2x4's and frame to local build- ing codes.

FIGURE 14

COUNTER TOP / BAR INSTALLATION

When fi nishing the fi replace, combustible material may rest directly on of the top extension.

NOTE: Maximum weight tolerance is 400 lbs, provided that it is evenly distributed across the top extensions of the fireplace.

In order to achieve a counter top or bar type appearance with the minimum height allowed, framing must be non-combusti- ble and may be done with metal studding attached to the top extension sides or the upper frame of the fi replace.

FIGURE 16

A = 22 " minus fi nishing material thickness each side.

To install the fi replace face fl ush with the fi nished wall, posi- tion the framework to accommodate the thickness of the fi nished wall.

FIGURE 15

Care should be taken to maintain suffi cient clearance for the vent installation. A horizontal vent installation requires a minimum height of 45" using fl exible vent pipe, to the underside of the enclosure top including the 2" clearance to combustibles.

*The top extension may be removed if non-combustible fram- ing is faced with a non-combustible material placed flush with the front face of the unit and extending from the top of the unit. (Example: cement board) (not supplied). Combustible counter / bar tops must maintain a minimum of 38" from the base of the fi replace to the underside of the top.

FIGURE 17

NOTE: Wolf Steel trim and/or surround kits will not totally cover the top extension of the fireplace. In order to obtain a smooth transition from the trim / surround to the wall, it is recommended that the top extension be removed and the unit be installed following the above procedure.

W415-0299 / J / 04.14.08

Image 14
Contents $10.00 W415-0299 / J Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Information IntroductionGeneral Instructions Care of GLASS, and Plated PartsDimensions Supplier VentingVenting Lengths Minimum AIR Terminal Location Clearances Horizontal run + verti- cal rise to maximum of 24.75 feet Venting Application FlowchartVertical Termination Special Vent Installation Periscope TerminationDefinitions When HT VTHorizontal Termination Elbow Vent Length ValuesFormula 2 HT + VT 24.75 feet Simple venting confi guration only one 45º and 90 elbowVertical Termination = V 1 + V 2 = 1 + 1.5 = 2.5 ft =1 ft=1.5 ft =6 ftVenting Peninsula Installation ProcedureCounter TOP / BAR Installation FramingBrick Panel Installation Facing FinishingOPEN-END Installation Procedure Brick Panel InstallationSEE-THROUGH Installation Procedure Venting FacingMinimum Vent Framing Dimensions Minimum Enclosure DimensionsAdjustable Firestop Installation Wall and Ceiling ProtectionHorizontal Installation Vertical InstallationUsing Flexible Vent Components Elbow SpacersGAS Installation Fireplace Vent ConnectionMinimum Mantel and Enclo Sure Clearances Optional Wall Switch InstallationFinishing LOG Placement Locating Pins #1 Locating PinsLogo Placement Door InstallationL36 Louvre Installation Glowing EmbersEND Door Installation Do not over-tightenOptional Blower Installation Do not overtighten thermodisc or distort housingFireplace Operation / MaintenanceMaintenance Venturi Adjustment AdjustmentsPilot Burner Adjustment Flame CharacteristicsGD430 10 Foot ReplacementsGD420 5 Foot W415-0299 / J Accessories # Part No. DescriptionTrouble Shooting Guide Symptom Problem Test SolutionRefer to Main Burner Goes OUT Pilot Stays on Fireplace Service History W415-0299 / J W415-0299 / J
Related manuals
Manual 36 pages 46.42 Kb

BGD40-P, BGD40-N specifications

Napoleon Fireplaces has long been a name synonymous with quality and innovation in the realm of hearth products. Among its impressive lineup, the BGD40-N and BGD40-P models stand out for their blend of performance, aesthetics, and technology, making them ideal choices for homeowners seeking both efficiency and style.

The BGD40-N is a natural gas fireplace, designed with an emphasis on creating a warm and inviting atmosphere. One of its main features is the glass front that enhances its visual appeal while providing a clear view of the mesmerizing flames. This model is equipped with Napoleon's patented PHAZER log set, which mimics the appearance of real wood, further enriching the realistic ambiance.

In contrast, the BGD40-P is a propane version of the fireplace, offering similar design aesthetics and functionality tailored to propane users. Both models boast a high-efficiency rating, which means they maximize heat output while minimizing gas consumption. This efficiency not only reduces energy costs but also makes them environmentally friendly options for home heating.

One of the standout technologies featured in the BGD40 series is the advanced electronic ignition system. This system ensures that igniting the fireplace is a hassle-free experience, even during power outages when using the optional battery backup. Furthermore, the exclusive Heat Management System provides optimal airflow and distribution of heat, ensuring that living spaces are warmed effectively and consistently.

Safety features are paramount in both models, with a built-in safety shut-off system that enhances peace of mind for users. Additionally, the adjustable flame height allows homeowners to customize their experience, ranging from a gentle glow to a roaring fire.

The design flexibility of the BGD40-N and BGD40-P allows them to fit seamlessly into various home décors, complementing both modern and traditional interiors. With their sleek lines and customizable options, including different media choices, these fireplaces serve as focal points in any room.

Installation is straightforward, with options available for both vented and direct vent configurations. This versatility means they can be installed in various locations, making them suited for new builds or retrofitting into existing structures.

In summary, Napoleon Fireplaces' BGD40-N and BGD40-P models deliver on aesthetics, efficiency, and innovative technology. With their realistic flame effects, user-friendly features, and commitment to safety, they are excellent choices for those seeking to enhance the comfort and ambiance of their homes.