Napoleon Fireplaces BGD40-P, BGD40-N manual Refer to Main Burner Goes OUT Pilot Stays on

Page 33

33

 

SYMPTOM

PROBLEM

 

TEST SOLUTION

 

Pilot will not light.

No spark at pilot burner

-

Check if pilot can be lit by a match

 

 

 

-

Check that the wire is connected to the push button igniter.

 

 

 

-

Check if the push button igniter needs tightening.

 

 

 

-

Replace the wire if the wire insulation is broken or frayed.

 

 

 

-

Replace the electrode if the ceramic insulator is cracked or broken.

 

 

 

-

Replace the push button igniter.

 

 

Out of propane gas

-

Fill the tank.

 

 

Spark gap is incorrect

-

Spark gap should be 0.150" to 0.175" (5/32" to 11/65" approx.)

 

 

 

from the electrode tip and the pilot burner. To ensure proper elec-

 

 

 

trode location, tighten securing nut (fi nger tight plus 1/4 turn).

 

 

No gas at the pilot burner

-

Check that the manual valve is turned on.

 

 

 

-

Check the pilot orifi ce for blockage.

 

 

 

-

Replace the valve.

 

 

 

-

Call the gas distributor.

 

Main burner goes out; pilot

Pilot fl ame is not large

-

Turn up pilot fl ame.

 

stays on.

enough or not engulfi ng the

-

Replace pilot assembly.

 

 

thermopile

 

 

 

 

Thermopile shorting

-

Clean thermopile connection to the valve. Reconnect.

 

 

 

-

Replace thermopile / valve.

 

 

Remote wall switch wire is

-

Shorten wire to correct length or wire gauge.

 

 

too long; too much resistance

 

 

 

 

in the system.

 

 

 

 

Faulty thermostat or switch.

-

Replace.

 

Main burner goes out; pilot

Refer to "MAIN BURNER GOES OUT; PILOT STAYS ON"

 

goes out.

Vent is blocked

-

Check for vent blockage.

 

 

 

 

Vent is re-circulating

-

Check joint seals and installation.

 

 

5" fl exible vent has become

-

Re-attach to fi replace.

 

 

disconnected from fi replace.

 

 

 

Remote wall switch is in "OFF"

Wall switch is mounted up-

-

Reverse.

 

position; main burner comes

side down

 

 

 

on when gas knob is turned to

Remote wall switch is

-

Replace.

 

"ON" position.

 

grounding.

 

 

 

 

 

 

 

 

Remote wall switch wire is

-

Check for ground (short); repair ground or replace wire.

 

 

grounding.

 

 

 

 

Faulty valve.

-

Replace.

 

 

 

 

 

 

Flames are very

Door is ajar

-

Tighten door clamps

 

aggressive.

Venting action is too great.

-

Restrict vent exit with restrictor vent kit, RP40-KT.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W415-0299 / J / 04.14.08

Image 33
Contents $10.00 W415-0299 / J Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Instructions IntroductionGeneral Information Care of GLASS, and Plated PartsDimensions Venting Venting LengthsSupplier Minimum AIR Terminal Location Clearances Venting Application Flowchart Vertical TerminationHorizontal run + verti- cal rise to maximum of 24.75 feet Periscope Termination Special Vent InstallationHorizontal Termination When HT VTDefinitions Elbow Vent Length ValuesSimple venting confi guration only one 45º and 90 elbow Formula 2 HT + VT 24.75 feetVertical Termination =1.5 ft =1 ft= V 1 + V 2 = 1 + 1.5 = 2.5 ft =6 ftCounter TOP / BAR Installation Peninsula Installation ProcedureVenting FramingFinishing Brick Panel Installation FacingBrick Panel Installation OPEN-END Installation ProcedureVenting Facing SEE-THROUGH Installation ProcedureMinimum Enclosure Dimensions Minimum Vent Framing DimensionsHorizontal Installation Installation Wall and Ceiling ProtectionAdjustable Firestop Vertical InstallationElbow Spacers Using Flexible Vent ComponentsFireplace Vent Connection GAS InstallationOptional Wall Switch Installation FinishingMinimum Mantel and Enclo Sure Clearances Locating Pins #1 Locating Pins LOG PlacementL36 Louvre Installation Door InstallationLogo Placement Glowing EmbersDo not over-tighten END Door InstallationDo not overtighten thermodisc or distort housing Optional Blower InstallationOperation / Maintenance MaintenanceFireplace Pilot Burner Adjustment AdjustmentsVenturi Adjustment Flame CharacteristicsReplacements GD420 5 FootGD430 10 Foot W415-0299 / J # Part No. Description AccessoriesSymptom Problem Test Solution Trouble Shooting GuideRefer to Main Burner Goes OUT Pilot Stays on Fireplace Service History W415-0299 / J W415-0299 / J
Related manuals
Manual 36 pages 46.42 Kb

BGD40-P, BGD40-N specifications

Napoleon Fireplaces has long been a name synonymous with quality and innovation in the realm of hearth products. Among its impressive lineup, the BGD40-N and BGD40-P models stand out for their blend of performance, aesthetics, and technology, making them ideal choices for homeowners seeking both efficiency and style.

The BGD40-N is a natural gas fireplace, designed with an emphasis on creating a warm and inviting atmosphere. One of its main features is the glass front that enhances its visual appeal while providing a clear view of the mesmerizing flames. This model is equipped with Napoleon's patented PHAZER log set, which mimics the appearance of real wood, further enriching the realistic ambiance.

In contrast, the BGD40-P is a propane version of the fireplace, offering similar design aesthetics and functionality tailored to propane users. Both models boast a high-efficiency rating, which means they maximize heat output while minimizing gas consumption. This efficiency not only reduces energy costs but also makes them environmentally friendly options for home heating.

One of the standout technologies featured in the BGD40 series is the advanced electronic ignition system. This system ensures that igniting the fireplace is a hassle-free experience, even during power outages when using the optional battery backup. Furthermore, the exclusive Heat Management System provides optimal airflow and distribution of heat, ensuring that living spaces are warmed effectively and consistently.

Safety features are paramount in both models, with a built-in safety shut-off system that enhances peace of mind for users. Additionally, the adjustable flame height allows homeowners to customize their experience, ranging from a gentle glow to a roaring fire.

The design flexibility of the BGD40-N and BGD40-P allows them to fit seamlessly into various home décors, complementing both modern and traditional interiors. With their sleek lines and customizable options, including different media choices, these fireplaces serve as focal points in any room.

Installation is straightforward, with options available for both vented and direct vent configurations. This versatility means they can be installed in various locations, making them suited for new builds or retrofitting into existing structures.

In summary, Napoleon Fireplaces' BGD40-N and BGD40-P models deliver on aesthetics, efficiency, and innovative technology. With their realistic flame effects, user-friendly features, and commitment to safety, they are excellent choices for those seeking to enhance the comfort and ambiance of their homes.