Napoleon Fireplaces BGD40-N, BGD40-P manual Table of Contents

Page 2

2

TABLE of CONTENTS

Pg 3-5 INTRODUCTION

Warranty

General Instructions

General Information

Care of Glass & Plated Parts

Dimensions

6-13 VENTING

Vent Lengths

Minimum Air Terminal Location Clearances

Venting Application Flow Chart

Typical Minimum and Maximum Vent Lengths

Special Vent Installation

Venting Options

14-15 PENINSULA INSTALLATION PROCEDURE

Framing

Bar / Counter top Installation

Brick Panel Installation

Facing

16OPEN END INSTALLATION PROCEDURE

Framing

Brick Panel Installation Facing

17SEE-THRU INSTALLATION PROCEDURE

Framing

Brick Panel Installation Facing

18VENT FRAMING DIMENSIONS

19-21 VENTING SPECIFICS

Wall and Ceiling Protection

Horizontal Venting Installation

Adjustable Firestop

Vertical Venting Installation

Flexible Vent Components

Fireplace Vent Connection

Rigid Vent Components

Gas Supply Connection

22-25 FINISHING

Mantel Installation and Enclosures

Heat shield stand-off

Log Placement

Logo Placement

Door Installation

Louvre Installation

End Door Installation

26OPTIONAL BLOWER INSTALLATION

27OPERATION / MAINTENANCE

Operating Instructions Maintenance

28ADJUSTMENTS

Pilot Burner Adjustment

Venturi Adjustments

Restricting Vertical Vents

29-30 REPLACEMENTS

Ordering Replacement Parts

Replacement Parts

Vent Kits

Terminal Kits

31 ACCESSORIES

32-33 TROUBLE SHOOTING GUIDE

34SERVICE HISTORY 35-35 NOTES

!WARNING

Do not burn wood or other materials in this fireplace.

Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the fireplace.

Clothing or other flammable material should not be placed on or near the fireplace.

Due to high temperatures, the fireplace should be located out of traffic and away from furniture and draperies.

Ensure you have incorporated adequate safety measure to protect infants/toddlers from touching hot surfaces.

Even after the fireplace is out, the glass and/or screen will remain hot for an extended period of time.

Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot surfaces. These screens and guards must be fastened to the floor.

Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace.

It is imperative that the control compartments, burners and circulating blower and its passageway in the fireplace and venting system are kept clean. The fireplace and its venting system should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. The fireplace area must be kept clear and free from combustible materials, gasoline and other flammable vapours and liquids.

Under no circumstances should this fireplace be modified.

This fireplace must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance.

Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.

Do not operate the fireplace with the glass door removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.

Do not strike or slam shut the fireplace glass door.

This fireplace uses and requires a fast acting thermocouple. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.

Pressure relief doors must be kept closed while the fireplace is operating to prevent exhaust fumes containing carbon monox- ide, from entering into the home. Temperatures of the exhaust escaping through these openings can also cause the surrounding combustible materials to overheat and catch fire.

Only doors / optional fronts certified with the unit are to be installed on the appliance.

NOTE: CHANGES, OTHER THAN EDITORIAL, ARE DENOTED BY A VERTICAL LINE IN THE MARGIN.

W415-0299 / J / 04.14.08

Image 2
Contents $10.00 W415-0299 / J Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Information IntroductionGeneral Instructions Care of GLASS, and Plated PartsDimensions Supplier VentingVenting Lengths Minimum AIR Terminal Location Clearances Horizontal run + verti- cal rise to maximum of 24.75 feet Venting Application FlowchartVertical Termination Special Vent Installation Periscope TerminationDefinitions When HT VTHorizontal Termination Elbow Vent Length ValuesFormula 2 HT + VT 24.75 feet Simple venting confi guration only one 45º and 90 elbowVertical Termination = V 1 + V 2 = 1 + 1.5 = 2.5 ft =1 ft=1.5 ft =6 ftVenting Peninsula Installation ProcedureCounter TOP / BAR Installation FramingBrick Panel Installation Facing FinishingOPEN-END Installation Procedure Brick Panel InstallationSEE-THROUGH Installation Procedure Venting FacingMinimum Vent Framing Dimensions Minimum Enclosure DimensionsAdjustable Firestop Installation Wall and Ceiling ProtectionHorizontal Installation Vertical InstallationUsing Flexible Vent Components Elbow SpacersGAS Installation Fireplace Vent ConnectionMinimum Mantel and Enclo Sure Clearances Optional Wall Switch InstallationFinishing LOG Placement Locating Pins #1 Locating PinsLogo Placement Door InstallationL36 Louvre Installation Glowing EmbersEND Door Installation Do not over-tightenOptional Blower Installation Do not overtighten thermodisc or distort housingFireplace Operation / MaintenanceMaintenance Venturi Adjustment AdjustmentsPilot Burner Adjustment Flame CharacteristicsGD430 10 Foot ReplacementsGD420 5 Foot W415-0299 / J Accessories # Part No. DescriptionTrouble Shooting Guide Symptom Problem Test SolutionRefer to Main Burner Goes OUT Pilot Stays on Fireplace Service History W415-0299 / J W415-0299 / J
Related manuals
Manual 36 pages 46.42 Kb

BGD40-P, BGD40-N specifications

Napoleon Fireplaces has long been a name synonymous with quality and innovation in the realm of hearth products. Among its impressive lineup, the BGD40-N and BGD40-P models stand out for their blend of performance, aesthetics, and technology, making them ideal choices for homeowners seeking both efficiency and style.

The BGD40-N is a natural gas fireplace, designed with an emphasis on creating a warm and inviting atmosphere. One of its main features is the glass front that enhances its visual appeal while providing a clear view of the mesmerizing flames. This model is equipped with Napoleon's patented PHAZER log set, which mimics the appearance of real wood, further enriching the realistic ambiance.

In contrast, the BGD40-P is a propane version of the fireplace, offering similar design aesthetics and functionality tailored to propane users. Both models boast a high-efficiency rating, which means they maximize heat output while minimizing gas consumption. This efficiency not only reduces energy costs but also makes them environmentally friendly options for home heating.

One of the standout technologies featured in the BGD40 series is the advanced electronic ignition system. This system ensures that igniting the fireplace is a hassle-free experience, even during power outages when using the optional battery backup. Furthermore, the exclusive Heat Management System provides optimal airflow and distribution of heat, ensuring that living spaces are warmed effectively and consistently.

Safety features are paramount in both models, with a built-in safety shut-off system that enhances peace of mind for users. Additionally, the adjustable flame height allows homeowners to customize their experience, ranging from a gentle glow to a roaring fire.

The design flexibility of the BGD40-N and BGD40-P allows them to fit seamlessly into various home décors, complementing both modern and traditional interiors. With their sleek lines and customizable options, including different media choices, these fireplaces serve as focal points in any room.

Installation is straightforward, with options available for both vented and direct vent configurations. This versatility means they can be installed in various locations, making them suited for new builds or retrofitting into existing structures.

In summary, Napoleon Fireplaces' BGD40-N and BGD40-P models deliver on aesthetics, efficiency, and innovative technology. With their realistic flame effects, user-friendly features, and commitment to safety, they are excellent choices for those seeking to enhance the comfort and ambiance of their homes.