ADJUSTMENTS

PILOT BURNER ADJUSTMENT

Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow.

FIGURE 62

FIGURE 63

! WARNING

This is a fast acting ther- mocouple. It is an inte- gral safety component. Replace only with a fast acting thermocouple sup- plied by Wolf Steel Ltd.

RESTRICTING VERTICAL VENTS

Vertical installations may display a very active flame. If this appearance is not desirable, the vent exit must be restricted using the optional restrictor vent kit, RP40-KT. This will reduce the velocity of the exhaust gases, slowing down the flame pat- tern and creating a more traditional gentle appearance.

1. Open the glass viewing door.

FIGURE 65a-c

SCREWS

 

2. Remove the three screws for mounting the restrictor plate located in the top of the fi rebox.

VENTURI ADJUSTMENT

Natural gas models have air shutters set at 1/4 (.250") inch open. Propane gas models have air shutters set at 7/16 (.437) inch open. Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner ports. The flame may not appear yellow immediately; allow 15 to 30 minutes for the fi nal fl ame colour to be established.

FIGURE 64

AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED GAS INSTALLER!

FLAME CHARACTERISTICS

It is important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the illustrations provided.

VENT

RESTRICTOR

3.Line up the holes on vent restrictor plate with the three holes from which the screws were removed.

4.Secure the vent restrictor plate into position using the three screws removed in step 2.

5.Replace the viewing door.

W415-0299 / J / 04.14.08

Image 28
Contents $10.00 W415-0299 / J Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Introduction General InstructionsGeneral Information Care of GLASS, and Plated PartsDimensions Venting Lengths VentingSupplier Minimum AIR Terminal Location Clearances Vertical Termination Venting Application FlowchartHorizontal run + verti- cal rise to maximum of 24.75 feet Special Vent Installation Periscope TerminationWhen HT VT Horizontal TerminationDefinitions Elbow Vent Length ValuesFormula 2 HT + VT 24.75 feet Simple venting confi guration only one 45º and 90 elbowVertical Termination =1 ft =1.5 ft= V 1 + V 2 = 1 + 1.5 = 2.5 ft =6 ftPeninsula Installation Procedure Counter TOP / BAR InstallationVenting FramingBrick Panel Installation Facing FinishingOPEN-END Installation Procedure Brick Panel InstallationSEE-THROUGH Installation Procedure Venting FacingMinimum Vent Framing Dimensions Minimum Enclosure DimensionsInstallation Wall and Ceiling Protection Horizontal InstallationAdjustable Firestop Vertical InstallationUsing Flexible Vent Components Elbow SpacersGAS Installation Fireplace Vent ConnectionFinishing Optional Wall Switch InstallationMinimum Mantel and Enclo Sure Clearances LOG Placement Locating Pins #1 Locating PinsDoor Installation L36 Louvre InstallationLogo Placement Glowing Embers END Door Installation Do not over-tightenOptional Blower Installation Do not overtighten thermodisc or distort housingMaintenance Operation / MaintenanceFireplace Adjustments Pilot Burner AdjustmentVenturi Adjustment Flame CharacteristicsGD420 5 Foot ReplacementsGD430 10 Foot W415-0299 / J Accessories # Part No. DescriptionTrouble Shooting Guide Symptom Problem Test SolutionRefer to Main Burner Goes OUT Pilot Stays on Fireplace Service History W415-0299 / J W415-0299 / J