MANUAL SHUT-OFF VALVE
6. Aligning the seams of the |
terminal and air terminal connector, |
21
FIREPLACE VENT CONNECTION
place the terminal over the air |
terminal connector making sure |
the liner goes into the hole in the |
terminal. Secure with the three |
screws provided. |
7. Apply a heavy bead of |
weatherproof caulking 2" |
above the fl ashing. NOTE: |
Maintain a minimum 2” space |
between the air inlet base |
and the storm collar. Install |
the storm collar around the |
air terminal and slide downFIGURE 40 to the caulking. Tighten to
ensure that a weather-tight seal between the air terminal and the collar is achieved.
1.Install the 5" diameter flex pipe to the fi replace. Secure with 3 screws and fl at washers. Seal the joint and screw holes using high temp sealant
(not supplied) or Red RTV Silicone may also be used in this location.
2.Install the 8" diam-
eter fl ex pipe to the
fireplace. Attach and seal the joints.
For optimum per-
formance it is recommended that all horizontal ¼" rise per foot.
GAS INSTALLATION
Proceed once the vent installation is complete.
NOTE: All gas connections must be contained within the fireplace when complete.
1.Move the fi replace into position and secure to the fl oor through the 1/4" holes located at either side of the base.
2.The fi replace is designed to accept 3/8" gas supply line.
3.Connect the gas supply in accordance to local codes. In the absence thereof, install according to the National Installation Code.
4.When fl exing any gas line, support the gas valve so that the lines are not bent
or kinked.
5. Check for gas leaks by brushing on a soap and water solution. | L |
O |
DO NOT USE OPEN FLAME. | HI |
Purge all gas lines with the glass door open. Assure that a continuous gas flow is at | P |
the burner before closing the door. | TOLI |
|
CERTIFIEDUNDER / HOMOLOGUE SELON LES NORMES: CSA 2.33-2002, ANSI Z21.88-2002 VENTED GAS FIREPLACE HEATER / FOYER DE CHAUFFAGE AU GAZ AVEC EVACUATION
DIRECT VENT GAS FIREPLACE.APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSAZ240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONTRUCTION AND SAFETY STANDARD,TITLE 24 CFR, PART 3280. WHENTHIS US STANDARD IS NOTAPPLICABLE USETHE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS,SITESAND COMMUNITIES, ANSI/ NFPA501A. FOYER A GAZ VENTILE DIRECT. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES,TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE APPLIQUEE, SE REFERERA LA NORME RELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A.
MODEL BGD40 - N | ALTITUDE/ELEVATION: | 0-4500FT(0-1370m) |
MODELBCDV400-N | INPUT/ALIMENTATION: | 30,000 BTU/h |
REDUCED INPUT/ALIMENTATION REDUIT: |
| | 20,000 BTU/h |
| ORIFICE: | #39 |
MANIFOLD PRESSURE: 3.5" WATER COLUMN
PRESSION AU COLLECTEUR: 3.5" D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE: 4.5" D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN
PRESSION D'ALIMENTATION MAXIMAL: 7.0" D'UNE COLONNE D'EAU
| | ALTITUDE / ELEVATION: | 0-4500FT (0-1370m) | MODEL BGD40 - P | | |
| | INPUT /ALIMENTATION: | | 30,000 BTU/h | MODELBCDV400-P | | |
| | REDUCED INPUT / ALIMENTATION REDUIT: | | |
| | |
| | | | 20,000 BTU/h | | | |
| | ORIFICE: | | #52 | | | |
REFERENCE #15510 | | | MANIFOLD PRESSURE: 10" WATER COLUMN |
| | PRESSION AU COLLECTEUR: 10" D'UNE COLONNE D'EAU |
CERTIFIEDFORCANADA AND USA | | MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN |
CERTIFIEEPOUR | ET | PRESSION D'ALIMENTATION MINIMALE: 11" D'UNE COLONNE D'EAU |
MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN
PRESSION D'ALIMENTATION MAXIMAL: 13" D'UNE COLONNE D'EAU
| NOT FOR USE WITH SOLID FUEL. FOR USE WITH COVERS AND | UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CET |
| GLASS DOORS CERTIFIED WITH THIS UNIT ONLY. | | APPAREIL. UTILISER AVEC LES COUVERTURES ET LES PORTES |
| WARNING:DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT | VITREES HOMOLOGUEES SEULEMENT AVEC CETTE UNITE. |
| WITHTHE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITHTHE APPLIANCE. | AVERTISSEMENT: N'AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT ENTRER EN |
| MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS / | |
| | CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE |
| DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES: | |
| | FABRICANT. |
| | |
| TOP, FLOOR, SIDES & BACK | 0 | THEAPPLIANCE MUST BE VENTED USING THEAPPROPRIATE WOLF STEEL VENT KITS. SEE OWNERS |
| INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS |
| DESSUS, PLANCHER, COTES & ARRIERE |
NECESSARY AFTER SERVICING THE VENT-AIR INTAKE SYSTEM.
RECESSED DEPTH (CORNER INSTALLATION ONLY)
PROFONDEUR D'ENCASTRE (INSTALLATION DU COIN SEULEMENT)
VENT / EVENT
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A WOLF STEEL. REFERER AUMANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL ESTIMPORTANT DE BIEN REINSTALLERET RESCELLER L'EVENT APRESAVOIR ASSURE LE MAINTIEN DU SYSTEME DE PRISE D'AIR.
MANTLE HEIGHT / HAUTEUR DU MANTEAU | 5"* |
*MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 3". SEE INSTRUC- TION MANUAL FOR GREATER EXTENSIONS. REFERER AU MANUEL D'INSTRUCTION POUR DES EXTENSIONS PLUS GRANDES.
MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE 10 INCHES AND 20 FEET RESPEC- TIVELY. LES LONGUEURS HORIZONTALES MINIMALE ET MAXIMALE SONT 10 POUCES ET 20 PIEDS RESPECTIVEMENT.
WOLF STEEL LTD, BARRIE, ON, CANADA
ELECTRICAL RATING / CLASSIFICATION: 115V, 0.82AMP, 60HZ
OPTIONAL FAN KIT / ENSEMBLE DE VENTILATEUR FACULTATIF: GZ-550KT
MADE IN CANADA / FABRIQUE AU CANADA
SERIAL NUMBER/NO. DE SERIE: BGD40 / BCDV400 | |
GD22 | W385-0249 |