Quick Installation Guide
Rosemount 3095 MultiVariable
Rosemount 3095 Fieldbus
Hazardous Locations Certifications
North American Certifications
FM Approvals
AExplosion Proof for Class I, Division 1, Groups B, C, and D.
JIntrinsically Safe for use in Class I, II and III, Division 1, Groups A, B, C, D, E, F, and G hazardous outdoor locations.
For input parameters and installation see control drawing
VFISCO for use in Class I, II and III, Division 1, Groups A, B, C, D, E, F, and G hazardous outdoor locations. Temperature Code T4. Factory Sealed.
For input parameters and installation see control drawing
Canadian Standards Association (CSA)
CExplosion Proof for Class I, Division 1, Groups B, C, and D.
KIntrinsically Safe for Class I, Division 1, Groups A, B, C, and D. When installed in accordance with Rosemount Drawing
WFISCO Field Device. Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D. When installed in accordance with Rosemount Drawing
European Certifications
F/T ATEX Intrinsic Safety Certificate Number: Baseefa 05ATEX0022X
II 1 G
EEx ia IIC T5 (Tamb =
1180
Table 8. Connection Parameters (Power/Signal Terminals)
Fieldbus (F Option) | FISCO (T Option) |
Ui = 30V | Ui = 17.5V |
Ii = 300 mA | Ii = 380 mA |
Pi = 1.3 W | Pi = 5.32 W |
Ci = 3.3 nF | Ci < 5 nF |
Li = 0 | Li = 10 µH |