Quick Installation Guide
Rosemount 3095 MultiVariable
STEP 1: MOUNT THE TRANSMITTER
Liquid Flow Applications
1. Place taps to the side of the line.
2. Mount beside or below the taps.
3. Mount the transmitter so that the drain/vent valves are oriented upward.
Flow
Gas Flow Applications
1. Place taps in the top or side of the line.
2. Mount beside or above the taps.
Flow
Flow
Steam Flow Applications
1. | Place taps to the side of the line. |
|
2. | Mount beside or below the taps. |
|
3. | Fill impulse lines with water. | Flow |
|
|
Figure 1. Using a Mounting Bracket |
|
Panel Mount(1) | Pipe Mount |
(1)Panel bolts are customer supplied.
4