OWNER’S MANUAL
OPERATING
FIREPLACE
Continued
BLOWER
OPERATION
MODEL VSGF28NTC
WARNING: This fireplace has a
Locate the blower switch by opening lower louver on fireplace. Blower switch is lo- cated at lower left inside louver door.
This
Note: It is safe to operate fireplace with blowerturnedoff.However,theblowerhelps distribute heated air from the fireplace.
MODEL VSGF28NVA
Blower Kit Model GA3700 Series
This optional
IMPORTANT: Light your gas appliance with the blower off.
Note: Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions.
Blower Kit Model GA3700T Series
Locate the blower switch by opening the lower louver on fireplace. Blower switch is located at lower left inside louver door.
The GA3700TA
IMPORTANT: Light your gas appliance with the blower off.
Note for GA3700TA: If you are using GA3700TA blower, your gas fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.
Note: It is safe to operate fireplace with blowerturnedoff.However,theblowerhelps distribute heated air from the fireplace.
Note: Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions.
Follow installation instructions included with the blower accessory.
INSPECTING
BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 31 shows a correct pilot flame pat- tern. Figure 32 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the fireplace will shut down.
If pilot flame pattern is incorrect, as shown in Figure 32
•turn fireplace off (seeTo Turn Off Gas to Appliance, page 15 [Thermostat-con- trolled models] or page 16 [Manually- controlled models])
•seeTroubleshooting, pages 19 through 21
Thermocouple
Pilot Burner
Figure 31 - Correct Pilot Flame Pattern
Thermocouple | Pilot Burner |
Figure 32 - Incorrect Pilot Flame Pattern
107157 | 17 | For more information, visit www.desatech.com |