OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY |
Fireplace produces a clicking/ticking noise just after burners are lit or shut off
1.Metal expanding while heating or con- tracting while cooling
1.This is common with most fireplaces. If noise is excessive, contact qualified ser- vice person
Fireplace produces unwanted odors | 1. | Fireplace burning vapors from paint, hair |
|
| spray, glues, cleaners, chemicals, new |
|
| carpet, etc. (See IMPORTANT state- |
|
| ment above) |
| 2. | Gas leak. See Warning statement |
|
| above |
1.Open window and ventilate room. Stop using odor causing products while fire- place is running
2.Locate and correct all leaks (see Check- ing Gas Connections, page 12)
Fireplace shuts off in use (ODS operates) | 1. | Not enough fresh air is available | 1. | Open window and/or door for ventilation |
| 2. | Low line pressure | 2. | Contact local natural gas company |
| 3. | ODS/pilot is partially clogged | 3. | Clean ODS/pilot (see Cleaning and |
|
|
|
| Maintenance, page 18 ) |
|
|
|
|
|
Gas odor even when control knob is in OFF | 1. | Gas leak. See Warning statement | 1. | Locate and correct all leaks (see Check- |
position |
| above |
| ing Gas Connections, page 12) |
| 2. | Control valve defective | 2. | Replace control valve |
|
|
|
|
|
Gas odor during combustion | 1. | Foreign matter between control valve |
|
| and burner |
| 2. | Gas leak. See Warning statement |
|
| above |
1.Take apart gas tubing and remove for- eign matter
2.Locate and correct all leaks (see Check- ing Gas Connections, page 12)
Moisture/condensation noticed on windows 1. Not enough combustion/ventilation air | 1. Refer to Air for Combustion and Venti- |
| lation requirements (page 4) |