UNVENTED NATURAL GAS FIREPLACE

INSTALLATION

Mantel Clearances for Built-In

INSTALLING GAS PIPING TO

Continued

Installation

FIREPLACE LOCATION

4.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.

5.Carefully insert fireplace into rough opening.

6.Attach flexible gas line to gas supply. See Connecting Fireplace to Gas Sup- ply, page 11.

7.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange (see Figure 15).

8.Check all gas connections for leaks. See Checking Gas Connections, page 12.

9.Plug electrical cord into electrical out- let installed in step 2, page 9.

10.Install brass trim after final finishing and/or painting of wall (see Figure 7, page 8).

39 3/8"

27 7/8"

35 1/2" 55 5/8"

Figure 14 - Rough Opening for Installing in Corner

Nails or

Wood

Screws

Nailing

Flanges

Figure 15 - Attaching Fireplace to Wall Studs

If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.

If your installation does not meet the below minimum clearances, you must:

raise the mantel to an acceptable height,

OR

remove the mantel.

 

 

 

Mantel

Note:

10"

 

Shelf

All Vertical

8"

 

 

 

 

 

 

 

 

measurements

6"

 

 

 

 

 

 

 

 

are from top of

 

 

 

 

2 1/2"

 

 

 

 

 

 

 

 

fireplace

 

 

 

 

 

opening to

 

 

 

 

 

bottom of

 

 

 

 

 

mantel shelf.

 

 

 

 

 

 

13"

16"

19"

21"

 

 

 

 

 

 

 

Figure 16 - Minimum Mantel Clearances for Built-In Installation

WARNING: This appliance re- quires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator.

WARNING: A qualified ser- vice person must connect fire- place to gas supply. Follow all local codes.

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

*A CSA/AGA. design-certified equipment shutoff valve with 1/8" NPT tap is an accept- able alternative to test gauge connection. Pur- chase the optional CSA/AGA. design-certi- fied equipment shutoff valve from your dealer. See Accessories, pages 22 and 23.

WARNING: Never connect fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to fireplace. If pipe is too small, undue loss of pressure will occur.

For more information, visit www.desatech.com

10

107157

Image 10
Contents VSGF28NTC OWNER’S Operation and Installation ManualVSGF28NVA What to do if YOU Smell GASSafety Information Unvented Natural GAS FireplaceLocal Codes Product IdentificationUnpacking Product Features AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationInstalling Hood Electrical HookupInstallation Clearances Conventional Fireplace InstallationBUILT-IN Fireplace Installation Actual Framing Height 32 3/8 Front Width DepthInstallation Items Needed Installing GAS Piping toInstallation Fireplace LocationConnecting Fireplace to GAS Supply Pipe Nipple Cap Tee Joint Sediment TrapPressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Installing Logs Installing Front Log #1Lighting Instructions For Your Safety Read Before LightingOperating Fireplace Thermostat-Controlled ModelsTo Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Variable Control Operation Model VSGF28NVA Inspecting BurnersBlower Operation Model VSGF28NTC Pilot Flame PatternFront Burner Flame Pattern Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole LogsTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement Service Hints Technical ServiceReplacement Parts Wiring DiagramSlim Hearth Base Brass Trim Accessory GA6090Cleaning KIT CCK Equipment Shutoff Valve GA5010Illustrated Parts Breakdown Parts List KEY Part Number Description QTYIllustrated PARTS7 Breakdown Fireplace VSGF28NVAParts List LOG Base Assembly THERMOSTAT- Controlled Model VSGF28NTC Parts List Fireplace VSGF28NTC Parts List Warranty Information