Vanguard Heating SBVBN(A) Fireplace Installation, Check GAS Type, Installation Items Needed

Page 12

®

B-VENT FREESTANDING FIREPLACE

FIREPLACE INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

CHECK GAS TYPE

Use proper gas type for the fireplace unit you are installing. If you have conflicting gas types, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace according to your gas type.

INSTALLING GAS PIPING TO FIREPLACE LOCATION

WARNING: A qualified ser- vice person must connect fire- place to gas supply. Follow all local codes.

CAUTION: For propane/LP units, never connect heater di- rectly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane/LP supply.

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

manual shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

approved flexible gas line with gas con- nector (if allowed by local codes) (not provided)

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the A.G.A. design-certified manual shutoff valve from your dealer.

For propane/LP connections only, the in- staller must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 25. Pointing the vent down protects it from freezing rain or sleet.

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to fireplace. If pipe is too small, undue loss of pressure will occur.

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 26, page 13).

Check your building codes for any special requirements for locating manual shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Install sediment trap/drip leg in supply line as shown in Figure 26, page 13. Locate sediment trap/drip leg where it is within reach for cleaning. Locate sediment trap/ drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas controls. If sediment trap/ drip leg is not installed or is installed wrong, fireplace may not run properly.

Propane/LP

Supply

Tank

External

Regulator

Vent

Pointing

Down

Figure 25 - External Regulator with Vent Pointing Down (Propane/LP Only)

12

105500

Image 12
Contents For Your Safety For Your Safety What to do if YOU Smell GASSBVBNA, Sbvbpa Remote Ready Safety Information Vent Freestanding FireplaceProduct Features Product IdentificationLocal Codes OperationPRE-INSTALLATION Preparation Location and Space RequirementsStove Body Assembly Use an adjustable wrench or a 10mm socketFreestanding Fireplace Assembly Installing Fireplace Into Stove BodyInstalling Optional Blower Accessory Installing GA3700/DA3610T BlowersVenting Installation Installing Rear CoverInstallation Precautions Installation of Listed B-1 Vent Type B-VENT Installation Listed B-0 or GreaterInstalling Vent System in a Chase Checking Vent CapacityChimneys Relining SystemsTroubleshooting Venting Problems High Altitude InstallationFlue GAS Spillage Causes of Spillage and Corrective ActionFireplace Installation Installing GAS Piping to Fireplace LocationInstallation Items Needed Check GAS TypeConnecting Fireplace to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Pressure Testing Fireplace Gas Connections Installing Optional Wall Mounted Thermostat GWMT1 Back View of Thermostat BaseInstalling Remote Receiver Installing 9-Volt Battery in Hand- Held Remote Control UnitREMOVING/REPLACING Glass Door Installing LOGS, Lava Rock and Glowing Embers Installing Log NoFor Your Safety Read Before Lighting Manual Lighting ProcedureOperating Fireplace Lighting InstructionsOptional Remote Operation Thermostat Control OperationGhrc Series Operation Ghrct Series OperationOperating Optional Blower Accessory Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatCleaning and Maintenance Glass DoorPilot and Burners LogsTroubleshooting After pilot lights, keep control knobPressed in 30 seconds Orifice Inlet gas pressure is too lowCompany Pane/LP or natural gas companyFireplace produces unwanted odors Tions onLow line pressure Pilot is partially cloggedReplacement Parts Technical ServiceWiring Diagram Service HintsSpecifications Sbvbna SbvbpaAccessories Illustrated Parts Breakdown Sbvbna SbvbpaParts List KEY Part Number Description QTYAmity SCIVF* Series PSCIVF* Series Indicates Color Suffix DesignationKEY Part Description QTY Warranty Information

SBVBN(A), SBVBP(A) specifications

Vanguard Heating SBVBN(A) and SBVBP(A) are advanced heating solutions designed to provide efficient temperature control for residential and commercial applications. Renowned for their innovative features and technologies, these models are engineered to enhance comfort while minimizing energy consumption.

One of the main characteristics of the SBVBN(A) and SBVBP(A) series is their high energy efficiency. Both models utilize advanced heat exchanger technology which allows them to extract maximum heat from the fuel consumed. This efficient heat transfer minimizes waste and leads to lower energy bills for users. The systems typically achieve impressive AFUE (Annual Fuel Utilization Efficiency) ratings, making them an environmentally friendly choice.

Another noteworthy feature of these heating units is their compact, space-saving design. Vanguard has effectively utilized modern engineering principles to produce equipment that can fit into various installation spaces without compromising performance. This is particularly advantageous for urban settings where space is limited.

The SBVBN(A) and SBVBP(A) models incorporate smart technology for enhanced user convenience. Smart thermostats and connectivity options allow users to control their heating systems remotely via smartphone applications. This capability provides greater flexibility and comfort, ensuring that homes and spaces are always at the ideal temperature.

Furthermore, noise reduction technology is integrated into these heating systems, ensuring quiet operation. This is particularly important for residential installations where a peaceful environment is desired. The design minimizes operational noise, allowing users to enjoy a tranquil atmosphere without the disturbance of traditional heating systems.

Safety features are also a prominent aspect of the Vanguard Heating SBVBN(A) and SBVBP(A) models. These include advanced flame sensing technology, automatic shut-off capabilities, and robust construction materials that enhance durability. These features not only ensure reliable performance but also provide peace of mind to users regarding safety concerns.

In terms of maintenance, Vanguard has made these systems user-friendly. They are designed for easy access to components, simplifying routine maintenance tasks and reducing overall service costs. This focus on ease-of-use contributes to the longevity and reliability of the heating systems.

Overall, Vanguard Heating SBVBN(A) and SBVBP(A) models stand out in the market due to their energy efficiency, advanced technologies, compact design, quiet operation, and comprehensive safety features. They embody a commitment to comfort, sustainability, and user satisfaction, making them a worthy choice for anyone in need of reliable heating solutions.