Vanguard Heating SBVBP(A), SBVBN(A) installation manual Accessories

Page 27

OWNER’S MANUAL

ACCESSORIES

Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800-432-2382. for information. You can also write to the ad- dress listed on the back page of this manual.

WALL MOUNTED THERMOSTAT CONTROL KIT GWMT1 (Not Shown)

Allows easy wall access to the operation of your fireplace. This will allow you thermo- static control with the convenience of a wall switch.

RECEIVER AND HAND-HELD REMOTE CONTROL KIT GHRC

For all models. Allows the heater to be turned on and off conveniently.

WALL MOUNTED ON/OFF SWITCH - GWMS2

(Not Shown)

Allows heater to be turned on and off with a wall switch.

MANUAL BLOWER KIT GA3700

Manual-variable control blower accessory for both the SBVBN(A) and SBVBP(A) Series fireplaces.

 

 

 

 

HI

 

M

AN

TE

MP

 

 

 

AU

 

 

L

 

TO

 

O

 

 

 

ON

 

 

 

 

 

 

 

 

O

 

 

 

 

FF

 

 

S

 

 

 

 

TAT

 

 

 

 

US

 

 

 

THERMOSTATICALLY- CONTROLLED BLOWER KIT DA3610T

Provides better heat distribution. Blower turns off and on automatically, as needed. Complete installation and operation instruc- tions included in this manual.

RECEIVER AND HAND-HELD THERMOSTAT REMOTE CONTROL KIT - GHRCT

Allows the fireplace to be operated in a manually or thermostatically controlled mode. You can adjust your heat settings and turn the heater on or off without leaving the comfort of your easy chair. (Requires part no. 103284-04 wire harness included with fireplace.)

105500

27

Image 27
Contents For Your Safety For Your Safety What to do if YOU Smell GASSBVBNA, Sbvbpa Remote Ready Vent Freestanding Fireplace Safety InformationOperation Product FeaturesProduct Identification Local CodesLocation and Space Requirements PRE-INSTALLATION PreparationUse an adjustable wrench or a 10mm socket Stove Body AssemblyInstalling Fireplace Into Stove Body Freestanding Fireplace AssemblyInstalling GA3700/DA3610T Blowers Installing Optional Blower AccessoryVenting Installation Installing Rear CoverInstallation Precautions Type B-VENT Installation Listed B-0 or Greater Installation of Listed B-1 VentRelining Systems Installing Vent System in a ChaseChecking Vent Capacity ChimneysCauses of Spillage and Corrective Action Troubleshooting Venting ProblemsHigh Altitude Installation Flue GAS SpillageCheck GAS Type Fireplace InstallationInstalling GAS Piping to Fireplace Location Installation Items NeededConnecting Fireplace to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Pressure Testing Fireplace Gas Connections Back View of Thermostat Base Installing Optional Wall Mounted Thermostat GWMT1Installing Remote Receiver Installing 9-Volt Battery in Hand- Held Remote Control UnitREMOVING/REPLACING Glass Door Installing Log No Installing LOGS, Lava Rock and Glowing EmbersLighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceGhrct Series Operation Optional Remote OperationThermostat Control Operation Ghrc Series OperationOperating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning and MaintenanceGlass Door Pilot and BurnersTroubleshooting After pilot lights, keep control knobPressed in 30 seconds Pane/LP or natural gas company OrificeInlet gas pressure is too low CompanyPilot is partially clogged Fireplace produces unwanted odorsTions on Low line pressureService Hints Replacement PartsTechnical Service Wiring DiagramSbvbna Sbvbpa SpecificationsAccessories Sbvbna Sbvbpa Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListIndicates Color Suffix Designation Amity SCIVF* Series PSCIVF* SeriesKEY Part Description QTY Warranty Information

SBVBN(A), SBVBP(A) specifications

Vanguard Heating SBVBN(A) and SBVBP(A) are advanced heating solutions designed to provide efficient temperature control for residential and commercial applications. Renowned for their innovative features and technologies, these models are engineered to enhance comfort while minimizing energy consumption.

One of the main characteristics of the SBVBN(A) and SBVBP(A) series is their high energy efficiency. Both models utilize advanced heat exchanger technology which allows them to extract maximum heat from the fuel consumed. This efficient heat transfer minimizes waste and leads to lower energy bills for users. The systems typically achieve impressive AFUE (Annual Fuel Utilization Efficiency) ratings, making them an environmentally friendly choice.

Another noteworthy feature of these heating units is their compact, space-saving design. Vanguard has effectively utilized modern engineering principles to produce equipment that can fit into various installation spaces without compromising performance. This is particularly advantageous for urban settings where space is limited.

The SBVBN(A) and SBVBP(A) models incorporate smart technology for enhanced user convenience. Smart thermostats and connectivity options allow users to control their heating systems remotely via smartphone applications. This capability provides greater flexibility and comfort, ensuring that homes and spaces are always at the ideal temperature.

Furthermore, noise reduction technology is integrated into these heating systems, ensuring quiet operation. This is particularly important for residential installations where a peaceful environment is desired. The design minimizes operational noise, allowing users to enjoy a tranquil atmosphere without the disturbance of traditional heating systems.

Safety features are also a prominent aspect of the Vanguard Heating SBVBN(A) and SBVBP(A) models. These include advanced flame sensing technology, automatic shut-off capabilities, and robust construction materials that enhance durability. These features not only ensure reliable performance but also provide peace of mind to users regarding safety concerns.

In terms of maintenance, Vanguard has made these systems user-friendly. They are designed for easy access to components, simplifying routine maintenance tasks and reducing overall service costs. This focus on ease-of-use contributes to the longevity and reliability of the heating systems.

Overall, Vanguard Heating SBVBN(A) and SBVBP(A) models stand out in the market due to their energy efficiency, advanced technologies, compact design, quiet operation, and comprehensive safety features. They embody a commitment to comfort, sustainability, and user satisfaction, making them a worthy choice for anyone in need of reliable heating solutions.