B-VENT FREESTANDING FIREPLACE

FREESTANDING FIREPLACE ASSEMBLY

Continued

INSTALLING REAR COVER

1.Lift rear panel over vent pipe connec- tion on firebox. Rear cover will rest on the bottom ledge of the stove body.

2.Using screws provided, attach rear cover to back of stove body. See Figure 17.

IMPORTANT: This rear cover must be securely in place before venting pipes are installed.

VENTING INSTALLATION

WARNING: Read all instruc- tions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage, or loss of life. Operation of im- properly installed and maintained venting system could result in serious injury, property damage, or loss of life.

NOTICE: Failure to follow these instructions will void the warranty.

INSTALLATION PRECAUTIONS

Consult local building codes before begin- ning the installation. Only a qualified ser- vice person should install venting system. The installer must follow these safety rules:

Wear gloves and safety glasses for protection

Use extreme caution when using ladders or when on roof tops

Be aware of electrical wiring locations in walls and ceilings

The following actions will void the war- ranty on your venting system:

Installation of any damaged venting

 

component

• Unauthorized modification of the vent-

 

ing system

Installation of any component part not

Rear

Cover

Screw

Firebox

Installed In Cast

Iron Stove Body

Figure 17 - Installing Rear Cover

manufactured or approved by DESA

International

• Installation other than as instructed by

these instructions

Your fireplace is approved for use with any listed gas vent. A listed gas vent is a factory made and listed system designed, and in- stalled exclusively for removing products of combustion, excess air, and dilution air resulting from burning fuel gas. Metal vents, the most common type of vent, employ double wall construction enclosing an insu- lating air space. This air space both helps keep flue gases warm and reduce heat trans- ferred to nearby combustibles. This appli- ance is equipped with a safety control sys- tem designed to protect against improper venting of combustion products.

It is very important that the venting system maintain its balance between the combus- tion air intake and the flue gas exhaust. Certain limitations apply to vent configura- tions and must be strictly followed.

WARNING: This gas fireplace and vent assembly must be vented directly to the outside. The venting system must NEVER be attached to a chimney serving a separate solid fuel burning appliance.

8

105500

Image 8
Contents SBVBNA, Sbvbpa Remote Ready For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information Vent Freestanding FireplaceProduct Features Product IdentificationLocal Codes OperationPRE-INSTALLATION Preparation Location and Space RequirementsStove Body Assembly Use an adjustable wrench or a 10mm socketFreestanding Fireplace Assembly Installing Fireplace Into Stove BodyInstalling Optional Blower Accessory Installing GA3700/DA3610T BlowersInstallation Precautions Venting InstallationInstalling Rear Cover Installation of Listed B-1 Vent Type B-VENT Installation Listed B-0 or GreaterInstalling Vent System in a Chase Checking Vent CapacityChimneys Relining SystemsTroubleshooting Venting Problems High Altitude InstallationFlue GAS Spillage Causes of Spillage and Corrective ActionFireplace Installation Installing GAS Piping to Fireplace LocationInstallation Items Needed Check GAS TypeChecking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas Connections Installing Optional Wall Mounted Thermostat GWMT1 Back View of Thermostat BaseREMOVING/REPLACING Glass Door Installing Remote ReceiverInstalling 9-Volt Battery in Hand- Held Remote Control Unit Installing LOGS, Lava Rock and Glowing Embers Installing Log NoFor Your Safety Read Before Lighting Manual Lighting ProcedureOperating Fireplace Lighting InstructionsOptional Remote Operation Thermostat Control OperationGhrc Series Operation Ghrct Series OperationOperating Optional Blower Accessory Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatCleaning and Maintenance Glass DoorPilot and Burners LogsPressed in 30 seconds TroubleshootingAfter pilot lights, keep control knob Orifice Inlet gas pressure is too lowCompany Pane/LP or natural gas companyFireplace produces unwanted odors Tions onLow line pressure Pilot is partially cloggedReplacement Parts Technical ServiceWiring Diagram Service HintsSpecifications Sbvbna SbvbpaAccessories Illustrated Parts Breakdown Sbvbna SbvbpaParts List KEY Part Number Description QTYAmity SCIVF* Series PSCIVF* Series Indicates Color Suffix DesignationKEY Part Description QTY Warranty Information

SBVBN(A), SBVBP(A) specifications

Vanguard Heating SBVBN(A) and SBVBP(A) are advanced heating solutions designed to provide efficient temperature control for residential and commercial applications. Renowned for their innovative features and technologies, these models are engineered to enhance comfort while minimizing energy consumption.

One of the main characteristics of the SBVBN(A) and SBVBP(A) series is their high energy efficiency. Both models utilize advanced heat exchanger technology which allows them to extract maximum heat from the fuel consumed. This efficient heat transfer minimizes waste and leads to lower energy bills for users. The systems typically achieve impressive AFUE (Annual Fuel Utilization Efficiency) ratings, making them an environmentally friendly choice.

Another noteworthy feature of these heating units is their compact, space-saving design. Vanguard has effectively utilized modern engineering principles to produce equipment that can fit into various installation spaces without compromising performance. This is particularly advantageous for urban settings where space is limited.

The SBVBN(A) and SBVBP(A) models incorporate smart technology for enhanced user convenience. Smart thermostats and connectivity options allow users to control their heating systems remotely via smartphone applications. This capability provides greater flexibility and comfort, ensuring that homes and spaces are always at the ideal temperature.

Furthermore, noise reduction technology is integrated into these heating systems, ensuring quiet operation. This is particularly important for residential installations where a peaceful environment is desired. The design minimizes operational noise, allowing users to enjoy a tranquil atmosphere without the disturbance of traditional heating systems.

Safety features are also a prominent aspect of the Vanguard Heating SBVBN(A) and SBVBP(A) models. These include advanced flame sensing technology, automatic shut-off capabilities, and robust construction materials that enhance durability. These features not only ensure reliable performance but also provide peace of mind to users regarding safety concerns.

In terms of maintenance, Vanguard has made these systems user-friendly. They are designed for easy access to components, simplifying routine maintenance tasks and reducing overall service costs. This focus on ease-of-use contributes to the longevity and reliability of the heating systems.

Overall, Vanguard Heating SBVBN(A) and SBVBP(A) models stand out in the market due to their energy efficiency, advanced technologies, compact design, quiet operation, and comprehensive safety features. They embody a commitment to comfort, sustainability, and user satisfaction, making them a worthy choice for anyone in need of reliable heating solutions.