Vanguard Heating SBVBP(A), SBVBN(A) Cleaning and Maintenance, Glass Door, Pilot and Burners, Logs

Page 21

OWNER’S MANUAL

CLEANING AND MAINTENANCE

WARNING: Turn off fireplace and let cool before cleaning.

CAUTION: You must keep con- trol areas, burners, and circulat- ing air passageways of fireplace clean. Inspect these areas of fire- place before each use. Have fire- place inspected yearly by a quali- fied service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

GLASS DOOR

WARNING: Handle glass door panel with care. Do not strike, slam or otherwise abuse glass. Do not operate fireplace with the glass door removed, cracked, or broken.

WARNING: Do not use abra- sive cleaners as this may damage glass. Use a non-abrasive house- hold glass cleaner to clean glass. Do not clean glass when hot.

Glass must be cleaned periodically. During start-up it is normal for condensation to form on the inside of the glass causing lint, dust, and other airborne particles to cling to the glass surface. During initial start-up a slight film may form on the glass due to paint curing. The glass should be cleaned several times with a non-amonia, non-abra- sive household cleaner and warm water after the first two weeks of operation. There- after, clean the glass two or three times during each heating season, depending on the usage and circumstances present. Refer to Removing/Replacing Glass Door on page 16 of this manual when removing glass door for cleaning.

WARNING: Only parts sup- plied by the manufacturer should be used when replacing broken or damaged glass door panel (see Replacement Parts, page 25). This glass door panel is a complete unit. No substitute materials may be used.

CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep chil- dren and pets away from glass.

If glass has been broken, carefully remove glass door (see Removing/Replacing Glass Door, page 16). Vacuum all glass pieces with a shop vac.

CAUTION: Do not vacuum if pieces are hot.

Use only the ceramic glass door replace- ment intended for this fireplace (see Re- placement Parts, page 25 for details on ordering). No substitutions may be made. See Removing/Replacing Glass Door, page 16 for instructions for replacing glass door.

WARNING: Do not operate fireplace with the glass door re- moved, cracked, or broken.

PILOT AND BURNERS

Remove ember material before clean- ing burners and replace when cleaning is complete.

Burner and controls should be cleaned with compressed air to remove dust, dirt, or lint.

Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt, or lint.

LOGS

If you remove logs for cleaning, refer to Installing Logs, Lava Rock, and Glowing Embers, page 17, to properly replace logs.

Use a vacuum cleaner to remove any car- bon build-up on logs.

Replace log(s) if broken. See Replace- ment Parts on page 25.

Replace ember material periodically as needed. See Replacement Parts on page 25.

VENTING SYSTEM

Conduct annual inspection of the venting system following these guidelines:

1.Check areas of venting system that are exposed to the weather for corrosion (rust spots or streaks and, in extreme cases, holes). Have these items replaced imme- diately by a qualified service person.

2.Remove the vent cap and shine a flashlight into the vent. Remove any foreign material.

3.Check for evidence of excessive con- densation. Continuous condensation can cause corrosion of caps, pipes, and fittings and can be caused by having excessive lateral runs, too many el- bows, or exterior portions of the sys- tem being exposed to cold weather.

4.Inspect joints to verify that no pipe sec- tion or fitting has been disturbed and loosened. Check mechanical supports such as wall straps for rigidity.

105500

21

Image 21
Contents For Your Safety For Your Safety What to do if YOU Smell GASSBVBNA, Sbvbpa Remote Ready Vent Freestanding Fireplace Safety InformationProduct Identification Product FeaturesLocal Codes OperationLocation and Space Requirements PRE-INSTALLATION PreparationUse an adjustable wrench or a 10mm socket Stove Body AssemblyInstalling Fireplace Into Stove Body Freestanding Fireplace AssemblyInstalling GA3700/DA3610T Blowers Installing Optional Blower AccessoryVenting Installation Installing Rear CoverInstallation Precautions Type B-VENT Installation Listed B-0 or Greater Installation of Listed B-1 VentChecking Vent Capacity Installing Vent System in a ChaseChimneys Relining SystemsHigh Altitude Installation Troubleshooting Venting ProblemsFlue GAS Spillage Causes of Spillage and Corrective ActionInstalling GAS Piping to Fireplace Location Fireplace InstallationInstallation Items Needed Check GAS TypeConnecting Fireplace to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Pressure Testing Fireplace Gas Connections Back View of Thermostat Base Installing Optional Wall Mounted Thermostat GWMT1Installing Remote Receiver Installing 9-Volt Battery in Hand- Held Remote Control UnitREMOVING/REPLACING Glass Door Installing Log No Installing LOGS, Lava Rock and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsThermostat Control Operation Optional Remote OperationGhrc Series Operation Ghrct Series OperationPilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning and MaintenancePilot and Burners LogsTroubleshooting After pilot lights, keep control knobPressed in 30 seconds Inlet gas pressure is too low OrificeCompany Pane/LP or natural gas companyTions on Fireplace produces unwanted odorsLow line pressure Pilot is partially cloggedTechnical Service Replacement PartsWiring Diagram Service HintsSbvbna Sbvbpa SpecificationsAccessories Sbvbna Sbvbpa Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListIndicates Color Suffix Designation Amity SCIVF* Series PSCIVF* SeriesKEY Part Description QTY Warranty Information

SBVBN(A), SBVBP(A) specifications

Vanguard Heating SBVBN(A) and SBVBP(A) are advanced heating solutions designed to provide efficient temperature control for residential and commercial applications. Renowned for their innovative features and technologies, these models are engineered to enhance comfort while minimizing energy consumption.

One of the main characteristics of the SBVBN(A) and SBVBP(A) series is their high energy efficiency. Both models utilize advanced heat exchanger technology which allows them to extract maximum heat from the fuel consumed. This efficient heat transfer minimizes waste and leads to lower energy bills for users. The systems typically achieve impressive AFUE (Annual Fuel Utilization Efficiency) ratings, making them an environmentally friendly choice.

Another noteworthy feature of these heating units is their compact, space-saving design. Vanguard has effectively utilized modern engineering principles to produce equipment that can fit into various installation spaces without compromising performance. This is particularly advantageous for urban settings where space is limited.

The SBVBN(A) and SBVBP(A) models incorporate smart technology for enhanced user convenience. Smart thermostats and connectivity options allow users to control their heating systems remotely via smartphone applications. This capability provides greater flexibility and comfort, ensuring that homes and spaces are always at the ideal temperature.

Furthermore, noise reduction technology is integrated into these heating systems, ensuring quiet operation. This is particularly important for residential installations where a peaceful environment is desired. The design minimizes operational noise, allowing users to enjoy a tranquil atmosphere without the disturbance of traditional heating systems.

Safety features are also a prominent aspect of the Vanguard Heating SBVBN(A) and SBVBP(A) models. These include advanced flame sensing technology, automatic shut-off capabilities, and robust construction materials that enhance durability. These features not only ensure reliable performance but also provide peace of mind to users regarding safety concerns.

In terms of maintenance, Vanguard has made these systems user-friendly. They are designed for easy access to components, simplifying routine maintenance tasks and reducing overall service costs. This focus on ease-of-use contributes to the longevity and reliability of the heating systems.

Overall, Vanguard Heating SBVBN(A) and SBVBP(A) models stand out in the market due to their energy efficiency, advanced technologies, compact design, quiet operation, and comprehensive safety features. They embody a commitment to comfort, sustainability, and user satisfaction, making them a worthy choice for anyone in need of reliable heating solutions.