Vanguard Heating SBVBP(A), SBVBN(A) installation manual Parts List, KEY Part Number Description QTY

Page 29

OWNER’S MANUAL

PARTS LIST

SBVBN(A)

SBVBP(A)

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 25 of this manual.

KEY

 

 

 

NO.

PART NUMBER

DESCRIPTION

QTY.

 

 

 

 

1

105479-01BR

Firebox Assembly

1

2

M11084-26

Screw, Hex

2

3

105484-01CK

Rear Cover

1

4

M11084-39

Screw, Hex

12

5

103587-02CK

Switch Plate

1

6

099998-01

On/Off Switch

1

7

103284-04

Wire Harness

1

8

103284-06

Wire Harness

1

9

105812-01BR

Baffle

1

10

105494-01

Spillswitch

1

11

M11084-43

Switch Screw

2

12

105468-01

Valve Bracket

1

13

105489-01

Valve, Natural

1

 

105489-02

Valve, Propane/LP

1

14

105488-01

Pilot Assembly, Natural

1

 

105488-02

Pilot Assembly, Propane/LP

1

15

102445-01

Ignitor, Piezo

1

16

102334-01

Palnut Fastener

1

17

105523-01

Burner, Natural

1

 

105523-02

Burner, Propane/LP

1

18

104506-03

Orifice, Natural

1

 

104506-04

Orifice, Propane/LP

1

19

104507-01

Brass Elbow

1

20

104508-01

Brass Fitting

2

21

105493-01

Aluminum Tubing Assy

1

22

105325-01

Air Deflector

1

23

105491-01

Log Set

1

23-1

105774-01

Rear Log

1

23-2

105774-02

Front Log

1

23-3

105774-03

Crossover Log

1

23-4

105774-04

Log Piece

1

24

M10908-2

Screw

2

25

M12461-50

Screw

3

26

M12461-62

Screw

2

27

104555-03CJ

Grate Assembly

1

28

105483-01

Burner Bracket

1

29

105795-01

Glass Door Assy

1

 

 

 

 

PARTS AVAILABLE - NOT SHOWN

 

105476-01

Lava Rock Plate

1

 

GA6060

Lava Rock

1

 

104529-01

Ember Material

1

 

M11084-3

Hex Screw for Blower Bracket

4

 

 

 

 

105500

29

Image 29
Contents SBVBNA, Sbvbpa Remote Ready For Your SafetyFor Your Safety What to do if YOU Smell GAS Vent Freestanding Fireplace Safety InformationProduct Identification Product FeaturesLocal Codes OperationLocation and Space Requirements PRE-INSTALLATION PreparationUse an adjustable wrench or a 10mm socket Stove Body AssemblyInstalling Fireplace Into Stove Body Freestanding Fireplace AssemblyInstalling GA3700/DA3610T Blowers Installing Optional Blower AccessoryInstallation Precautions Venting InstallationInstalling Rear Cover Type B-VENT Installation Listed B-0 or Greater Installation of Listed B-1 VentChecking Vent Capacity Installing Vent System in a ChaseChimneys Relining SystemsHigh Altitude Installation Troubleshooting Venting ProblemsFlue GAS Spillage Causes of Spillage and Corrective ActionInstalling GAS Piping to Fireplace Location Fireplace InstallationInstallation Items Needed Check GAS TypeChecking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas Connections Back View of Thermostat Base Installing Optional Wall Mounted Thermostat GWMT1REMOVING/REPLACING Glass Door Installing Remote ReceiverInstalling 9-Volt Battery in Hand- Held Remote Control Unit Installing Log No Installing LOGS, Lava Rock and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsThermostat Control Operation Optional Remote OperationGhrc Series Operation Ghrct Series OperationPilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning and MaintenancePilot and Burners LogsPressed in 30 seconds TroubleshootingAfter pilot lights, keep control knob Inlet gas pressure is too low OrificeCompany Pane/LP or natural gas companyTions on Fireplace produces unwanted odorsLow line pressure Pilot is partially cloggedTechnical Service Replacement PartsWiring Diagram Service HintsSbvbna Sbvbpa SpecificationsAccessories Sbvbna Sbvbpa Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListIndicates Color Suffix Designation Amity SCIVF* Series PSCIVF* SeriesKEY Part Description QTY Warranty Information

SBVBN(A), SBVBP(A) specifications

Vanguard Heating SBVBN(A) and SBVBP(A) are advanced heating solutions designed to provide efficient temperature control for residential and commercial applications. Renowned for their innovative features and technologies, these models are engineered to enhance comfort while minimizing energy consumption.

One of the main characteristics of the SBVBN(A) and SBVBP(A) series is their high energy efficiency. Both models utilize advanced heat exchanger technology which allows them to extract maximum heat from the fuel consumed. This efficient heat transfer minimizes waste and leads to lower energy bills for users. The systems typically achieve impressive AFUE (Annual Fuel Utilization Efficiency) ratings, making them an environmentally friendly choice.

Another noteworthy feature of these heating units is their compact, space-saving design. Vanguard has effectively utilized modern engineering principles to produce equipment that can fit into various installation spaces without compromising performance. This is particularly advantageous for urban settings where space is limited.

The SBVBN(A) and SBVBP(A) models incorporate smart technology for enhanced user convenience. Smart thermostats and connectivity options allow users to control their heating systems remotely via smartphone applications. This capability provides greater flexibility and comfort, ensuring that homes and spaces are always at the ideal temperature.

Furthermore, noise reduction technology is integrated into these heating systems, ensuring quiet operation. This is particularly important for residential installations where a peaceful environment is desired. The design minimizes operational noise, allowing users to enjoy a tranquil atmosphere without the disturbance of traditional heating systems.

Safety features are also a prominent aspect of the Vanguard Heating SBVBN(A) and SBVBP(A) models. These include advanced flame sensing technology, automatic shut-off capabilities, and robust construction materials that enhance durability. These features not only ensure reliable performance but also provide peace of mind to users regarding safety concerns.

In terms of maintenance, Vanguard has made these systems user-friendly. They are designed for easy access to components, simplifying routine maintenance tasks and reducing overall service costs. This focus on ease-of-use contributes to the longevity and reliability of the heating systems.

Overall, Vanguard Heating SBVBN(A) and SBVBP(A) models stand out in the market due to their energy efficiency, advanced technologies, compact design, quiet operation, and comprehensive safety features. They embody a commitment to comfort, sustainability, and user satisfaction, making them a worthy choice for anyone in need of reliable heating solutions.