Harman Stove Company The Harman Accentra Pellet Insert Venting27, With outside air installed

Page 26

Venting27

Requirements for Terminating the Venting WARNING: Venting terminals must not be re-

cessed into a wall or siding.

NOTE: Only PL vent pipe wall pass-throughs and fire stops should be used when venting through combustible materials.

NOTE: Always take into consideration the ef- fect the prevailing wind direction or other wind cur- rents will cause with flyash and /or smoke when plac- ing the termination.

In addition, the following must be observed: A. The clearance above grade must be a mini-

mum of 18".1

B. The clearance to a window or door that may be opened must be a minimum of 48" to the side and 48" below the window/door, and 12" above the window/door. 1

( with outside air installed, 18” )

C. A 12" clearance to a permanently closed win- dow is recommended to prevent condensation on the window.

D. The vertical clearance to a ventilated soffit located above the terminal within a horizontal dis- tance of 2 feet (60 cm) from the center-line of the terminal must be a minimum of 18".

E. The clearance to an unventilated soffit must be a minimum of 12".

F. The clearance to an outside corner is 11" from center of pipe.

G. The clearance to an inside corner is 12".

H.A vent must not be installed within 3 feet (90 cm) above a gas meter/regulator assembly when measured from the horizontal center-line of the regu- lator.1

I. The clearance to service regulator vent outlet must be a minimum of 6 feet.1

J. The clearance to a non-mechanical air sup-

ply inlet to the building or the combustion air inlet to any other appliance must be a minimum of 48”.1

K. The clearance to a mechanical air supply inlet must be a minimum of 10 feet.1

(with outside air installed, 6 feet )

L. The clearance above a paved sidewalk or a paved driveway located on public property must be a minimum of 7 feet.1,2

M. The clearance under a veranda, porch, deck or balcony must be a minimum of 12 inches.1,3

NOTE: The clearance to vegetation and other exterior combustibles such as mulch is 36” as mea- sured from the center of the outlet or cap. This 36”

radius continues to grade or a minimum of 7 feet below the outlet.

1Certain Canadian and or Local codes or regu- lations may require different clearances.

2A vent shall not terminate directly above a side- walk or paved driveway which is located between two single family dwellings and serves both dwell- ings.

3Only permitted if veranda, porch, deck, or bal- cony is fully open on a minimum of 2 sides beneath the floor.

NOTE: Where passage through a wall, or partition of combustible construction is desired, the installation shall conformto CAN/CSA-B365. (if in Canada)

I ns ide

Corner

Det ail

Fixed

 

 

Closed

Openable

Fixed

 

 

Closed

Openable

 

 

V

= Vent terminal

A = Air supply inlet

= Area where terminal is not permitted

Image 26
Contents Installation & Operating Manual Harman Accentra Pellet InsertTable of Contents Introduction3Automatic Start Up Starting First FireIgniter switch to Auto Stove Temperature Mode Stove Temperature ModeIgniter switch to Auto Room Temperature Mode Shut-Down ProcedureIgniter Switch toMANUAL down position Manual Start UpIgniter Switch to Manual Stove Temperature Mode Manual Stove Temperature ModeIgniter Switch to Manual Room Temperature Mode Manual Ignition/OperationStatus light error messages ESP ControlInstallation Removing unit from skid How to Reduce the Weight for InstallationRemoving the Center Medallion Installation10How to Reduce the Weight for Installation, contd Removing the Heat Exchanger CoversInstallation11 SecurelyInstallation12 Installation13 Connecting the room sensor as a return airsensorInstallation14 Flue Pipe Stub AssemblyConnecting the power cord Installation15Connecting the ground from the wing to Stove body Docking Gasket Installation16Connecting the Room Sensor Hopper SealInstallation17 Cast Side Panel InstallationInstallation18 Wiring Log Set OptionLow Draft Voltage Adjustment Draft Meter bolt hole locationSafety Reminders Mobile Home InstallationMobile Home Installation Venting21 PL Vent PipeVent Pipe Venting22Outside Air #1 Installing into an existing fireplace Chimney US & Canada Venting23#4 Preferred method #3 Installing into an existing Chimney US onlyVenting24 Venting25 Accentra Insert Zero Clearance Cabinet Harman Mantel SystemVenting27 With outside air installedWith outside air installed, 6 feet Maintenance Cleaning Glass on View Door Maintenance Burn Pot Burn Pot Cleaning and MaintenanceCleaning the Heat Exchanger Maintenance Cleaning30Cleaning the Heat Exchanger tubes To remove the combustion blower Maintenance Cleaning31To remove the feeder cover Backdraft Damper Assembly Accentra Insert Motor & Component LocationsHelpful Hints Trouble-Shooting33Cleaning Burn Pot FuelSpecifications34 Accentra Insert Wiring Diagram Accentra Insert Feeder Parts Accentra Insert Parts List Harman Gold Warranty Harman Gold Warranty

The Harman Accentra Pellet Insert specifications

The Harman Stove Company is renowned for its high-quality heating solutions, and the Harman Accentra Pellet Insert exemplifies their commitment to efficiency and performance. Designed to seamlessly blend into existing fireplace openings, the Accentra Pellet Insert offers homeowners a reliable source of warmth while enhancing the aesthetics of their living space.

One of the standout features of the Accentra is its advanced pellet-burning technology. This insert utilizes a powerful feed system that ensures a consistent and controllable burn rate, leading to a more efficient heating experience. The patented Smart Control technology enables users to monitor and adjust the temperature easily, ensuring that every room is kept at the perfect temperature with minimal effort.

The Accentra Pellet Insert also comes equipped with a user-friendly interface, making it accessible even for those unfamiliar with pellet stoves. Its LCD screen displays vital information, including temperature settings and fuel levels, allowing users to make informed adjustments. This level of convenience is complemented by the unit's automatic ignition feature, which simplifies startup, eliminating the need for matches or manual lighting.

In terms of efficiency, the Harman Accentra boasts an impressive high-efficiency rating. With a heating capacity of up to 2,200 square feet, it provides substantial warmth, making it an ideal choice for larger homes or open spaces. The insert’s environmentally-friendly design minimizes emissions, contributing to cleaner air and promoting sustainable heating practices.

The construction of the Accentra Pellet Insert is equally impressive. Built with durable materials, it is designed for longevity and dependability. The insert's sleek and contemporary design fits neatly into a variety of home decors, allowing homeowners to enjoy a cozy fire without sacrificing style.

Another key characteristic of the Accentra Pellet Insert is its versatility in fuel options. Users can choose from various brands of pellets, optimizing fuel choices based on availability and pricing. With a large capacity hopper, the Accentra can hold ample pellets, reducing the frequency of refueling and allowing for extended burn times.

In summary, the Harman Accentra Pellet Insert embodies the company's dedication to quality and innovation. With its efficient heating capabilities, advanced technology, user-centric design, and adaptability, it stands out as a premium choice for anyone looking to enhance their home’s heating system while enjoying the comforting glow of a real fire. Investing in the Harman Accentra is not just a choice for warmth; it's a commitment to quality, aesthetics, and sustainable living.