Harman Stove Company The Harman Accentra Pellet Insert ESP Control, Status light error messages

Page 7

ESP Control

8

Power Light Indicates power to the control.

Status Light

Will be lit in either stove or room temp mode when pointer is not within off position band except after normal shut down. Blinks to indicate errors listed below.

Indicates power to distribution blower.

Indicates power to combustion blower

Indicates power to the feed motor.

Indicates igniter is on.

Temp dial

Allows you to adjust the room temperature in Room Temp Mode using the outer scale marked in degrees Fahrenheit. It also allows you to adjust the stove temperature while in Stove Temp Mode using the inner scale marked from 1 to 7.

Status light error messages:

Dealer Diagnostic Port For dealer maintenance only. Requires special DDM monitor supplied to Harman Dealers exclusively.

Feed adjuster Sets the maximum feed rate

Test

Runs all motors atfull speed for one minute to check operation. After two minutes the stove will go to minimum burn and the blowers will alternate from high to low every minute to remind you that you are still in "Test Mode".

Igniter switch

Setto appropriate

Start-Up mode.

Distribution Blower speed adjustmentrange. L = low

H = high

Variable speed anywhere between L and H; although as the stove temp. goes up , so does the L and H scale.

Mode Selector

Allows you to choose between Room Temp Mode, Stove Temp Mode, or OFF. Also allows you to vary the distribution blower speed by turning the knob to the high or lowside of each mode.

1 Blink: Indicates control board self diagnostic fail- ure. This requires a manual reset*.

3 Blinks: Indicates ESP (Exhaust Sensing Probe) failure. This requires a manual reset*.

4Blinks: Can occur only in Room Temp Mode and indicates Room Sensing Probe failed or not in- stalled. If a Room Sensing Probe is then installed, the status light will automatically reset.

NOTE: Unit will not start in "AUTO" with this status error.

5Blinks (In Igniter Auto. Mode Only): Indicates that the unit has failed to light within the 36 minute start cycle. To reset - Turn Mode Selector to "OFF", then turn to either mode again.)

6 Blinks : Indicates that the control has calculated poor or incomplete combustion occurring for more than 50 minutes.

A six blink status may be set if the stove is allowed to run out of pellets. To reset, turn mode selector to "OFF" then back on to the desired mode. If the unit was not out of pellets, see Troubleshooting section, Page 24, for more details.

*Manual reset- disconnect power cord for a few seconds and reconnect. If error still occurs call your Dealer.

Image 7
Contents Harman Accentra Pellet Insert Installation & Operating ManualIntroduction3 Table of ContentsStarting First Fire Automatic Start UpShut-Down Procedure Stove Temperature ModeIgniter switch to Auto Room Temperature Mode Igniter switch to Auto Stove Temperature ModeManual Start Up Igniter Switch toMANUAL down positionManual Ignition/Operation Manual Stove Temperature ModeIgniter Switch to Manual Room Temperature Mode Igniter Switch to Manual Stove Temperature ModeESP Control Status light error messagesHow to Reduce the Weight for Installation Installation Removing unit from skidRemoving the Heat Exchanger Covers Installation10How to Reduce the Weight for Installation, contd Removing the Center MedallionSecurely Installation11Installation12 Connecting the room sensor as a return airsensor Installation13Flue Pipe Stub Assembly Installation14Connecting the ground from the wing to Stove body Installation15Connecting the power cord Hopper Seal Installation16Connecting the Room Sensor Docking GasketCast Side Panel Installation Installation17Wiring Log Set Option Installation18Draft Meter bolt hole location Low Draft Voltage AdjustmentMobile Home Installation Mobile Home InstallationSafety Reminders PL Vent Pipe Venting21Outside Air Venting22Vent Pipe Venting23 #1 Installing into an existing fireplace Chimney US & CanadaVenting24 #3 Installing into an existing Chimney US only#4 Preferred method Venting25 Harman Mantel System Accentra Insert Zero Clearance CabinetWith outside air installed, 6 feet With outside air installedVenting27 Maintenance Cleaning Glass on View Door Burn Pot Cleaning and Maintenance Maintenance Burn PotCleaning the Heat Exchanger tubes Maintenance Cleaning30Cleaning the Heat Exchanger To remove the feeder cover Maintenance Cleaning31To remove the combustion blower Accentra Insert Motor & Component Locations Backdraft Damper AssemblyFuel Trouble-Shooting33Cleaning Burn Pot Helpful HintsSpecifications34 Accentra Insert Wiring Diagram Accentra Insert Feeder Parts Accentra Insert Parts List Harman Gold Warranty Harman Gold Warranty

The Harman Accentra Pellet Insert specifications

The Harman Stove Company is renowned for its high-quality heating solutions, and the Harman Accentra Pellet Insert exemplifies their commitment to efficiency and performance. Designed to seamlessly blend into existing fireplace openings, the Accentra Pellet Insert offers homeowners a reliable source of warmth while enhancing the aesthetics of their living space.

One of the standout features of the Accentra is its advanced pellet-burning technology. This insert utilizes a powerful feed system that ensures a consistent and controllable burn rate, leading to a more efficient heating experience. The patented Smart Control technology enables users to monitor and adjust the temperature easily, ensuring that every room is kept at the perfect temperature with minimal effort.

The Accentra Pellet Insert also comes equipped with a user-friendly interface, making it accessible even for those unfamiliar with pellet stoves. Its LCD screen displays vital information, including temperature settings and fuel levels, allowing users to make informed adjustments. This level of convenience is complemented by the unit's automatic ignition feature, which simplifies startup, eliminating the need for matches or manual lighting.

In terms of efficiency, the Harman Accentra boasts an impressive high-efficiency rating. With a heating capacity of up to 2,200 square feet, it provides substantial warmth, making it an ideal choice for larger homes or open spaces. The insert’s environmentally-friendly design minimizes emissions, contributing to cleaner air and promoting sustainable heating practices.

The construction of the Accentra Pellet Insert is equally impressive. Built with durable materials, it is designed for longevity and dependability. The insert's sleek and contemporary design fits neatly into a variety of home decors, allowing homeowners to enjoy a cozy fire without sacrificing style.

Another key characteristic of the Accentra Pellet Insert is its versatility in fuel options. Users can choose from various brands of pellets, optimizing fuel choices based on availability and pricing. With a large capacity hopper, the Accentra can hold ample pellets, reducing the frequency of refueling and allowing for extended burn times.

In summary, the Harman Accentra Pellet Insert embodies the company's dedication to quality and innovation. With its efficient heating capabilities, advanced technology, user-centric design, and adaptability, it stands out as a premium choice for anyone looking to enhance their home’s heating system while enjoying the comforting glow of a real fire. Investing in the Harman Accentra is not just a choice for warmth; it's a commitment to quality, aesthetics, and sustainable living.