ERRORS AND SELF DIAGNOSIS
Error Code
TIMER SET TIME TEMP./DAY | FAN |
MODE | CONTROL |
MASTER
CONTROL
CLOCK ADJUST
ZONE | ENERGY SAVE START/STOP | ||
SET | DAY OFF |
|
|
|
If there is a problem with the air conditioner, it will stop run- ning and “E: EE” will be displayed instead of the clock.
(1)If the operation lamp is on then press the START/ STOP button to turn it off.
(2)Press the SET TIME (▼) and the TEMP./DAY (▼) buttons at the same time for more than three seconds to start the self diagnosis check.
An error code will be displayed in the clock display area.
(3)Press the SET TIME (▼) and the TEMP./DAY (▼) buttons again for more than three seconds to end the self diag- nosis check.
Error Code | Error contents | |||
Communication error | ||||
(indoor unitt |
|
| sremote controller) | |
|
| |||
|
|
|
|
|
Communication error | ||||
t |
|
| s | |
|
| |||
(indoor unit |
|
| outdoor unit) | |
Room temperature sensor open |
Room temperature sensor shortcircuited
Indoor heat exchanger temperature sensor open
Indoor heat exchanger temperature sensor shortcircuited
Outdoor heat exchanger temperature sensor open
Outdoor heat exchanger temperature sensor shortcircuited
Power source connection error
Float switch operated
Outdoor temperature sensor open
Outdoor temperature sensor shortcircuited
Discharge pipe temperature sensor open
Discharge pipe temperature sensor shortcircuited
Outdoor high pressure abnormal
Discharge pipe temperature abnormal
Model abnormal
Indoor fan abnormal
Outdoor signal abnormal
Outdoor EEPROM abnormal