Empire Comfort Systems VFSM-30-3 installation instructions VFSM-18,24,30 Lighting Instructions

Page 15

VFSM-(18,24,30) LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch;

do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information.

2.Make sure the manual shutoff valve is fully open.

3.This heater is equipped with an ignition device (piezo) which automatically lights the pilot.

4.Refer to Figure 15 for the location of the piezo ignitor and control knob. Push in gas control knob slightly and turn

control knob clockwise to the OFF position. NOTE: Knob cannot be turned to OFF unless knob is pushed in slightly. Do not force.

5.Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas STOP! Follow the instructions under ‘What To Do If You Smell Gas”. If you do not smell gas, go to the next step.

6.From OFF position, push in gas control knob slightly and

turn counterclockwiseto the PILOT position. Push in and hold control knob for 5 seconds.

NOTE: If you are running the heater for the first time, it will be necessary to press in the control knob for 30 seconds to allow air to bleed out of the gas piping.

7.With the control knob pushed in, push and release the piezo ignitor button to light the ODS pilot. The pilot is located on the right rear side of the heater, behind the middle log and in front of the rear log. If piezo ignitor does not light the pilot, refer to “Match Lighting Instructions”.

8.Hold the control knob in for an additional 10 seconds to prevent the ODS pilot from shutting off the gas while the thermocouple is warming up.

9.Release the control knob.

* If the knob does not pop out when released, stop and immediately call your service technician or gas

supplier.

*If the ODS pilot will not stay lit after several tries, push

and turn the gas control knob clockwise to OFF and wait 15 seconds. Repeat steps 6 through 9.

10.Push in control knob and turn to desired setting (1, 2, 3). The control knob must be set at either the low or high position, and the control knob will pop out when positioned correctly. Do not set the control knob at a position between pilot (1, 2, 3).

TO TURN OFF GAS TO APPLIANCE

1.Turn control knob clockwise to OFF position to completely shut off the heater.

18954-2-0107

Page 15

Image 15
Contents Millivolt Variable Manual Installation InstructionsTable of Contents Death Important Safety InformationDo not Tamper with Pilot Light Safety Carbon Monoxide Poisoning MAY Lead toLP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction New InstallationGeneral Information Before you get startedMake sure you have received all parts Glass Doors ClearancesClearances Fireplace Preparation Combustible MaterialInstalling AS a Vented Appliance Before Fully Installing the ApplianceInstalling Damper Clamp Figure Recommended Gas Pipe Diameter Installing a New Main Gas CockPressure Testing of the Gas Supply System GAS SupplyVariable Figure Millivolt Figure Manual Figure Placement of Glowing Embers and Lava RockOperation INSTRUCTIONS/FLAME Appearance Placing Lava Rock in Front of Burner on Fireplace FloorWhat to do if YOU Smell GAS VFSR-16,18,24,30 Lighting InstructionsLighting Instructions VFSM-18,24,30 Lighting Instructions Correct Pilot Flame Pattern Incorrect Pilot Flame Pattern Pilot Flame CharacteristicsVfsr Pilot Vfsv and Vfsm PilotTurn OFF Heater and Allow to Cool Before Cleaning Cleaning and ServicingWiring VfsrVfsv Appliance produces unwanted odors Gas odor even when control knob is in OFF positionHeater produces a whistling noise when main burner is lit New InstallationIndex Part Description Parts ListParts View HOW to Order Repair Parts Service Notes Service Notes

VFSM-30-3 specifications

The Empire Comfort Systems VFSM-30-3 is a state-of-the-art vent-free gas fireplace that combines functionality with aesthetic appeal. Ideal for homes without traditional venting systems, this fireplace brings warmth and a cozy ambiance to any space while maintaining an efficient energy usage standard.

One of the main features of the VFSM-30-3 is its impressive heat output. With a heating capacity of up to 30,000 BTUs, it effectively warms areas up to 1,200 square feet, making it suitable for both small and large living spaces. The unit’s design incorporates a durable steel construction, ensuring longevity and resistance to wear over time.

The versatility of the Empire VFSM-30-3 is notable, as it can be powered by either natural gas or propane, allowing homeowners flexibility in fuel choice. It also features an adjustable flame height, giving users the option to create their desired level of warmth and ambiance. This is complemented by its realistic log set, which enhances the visual appeal, replicating the look of a traditional wood-burning fireplace.

Another significant characteristic of the VFSM-30-3 is its advanced vent-free technology. This innovative system allows for efficient combustion without the need for a chimney or flue, greatly reducing installation costs and complexities. The vent-free design also ensures that 100% of the heat generated is utilized within the room, providing exceptional energy efficiency.

Safety is a top priority with the Empire VFSM-30-3. The fireplace comes equipped with an oxygen depletion sensor, which automatically shuts off the gas supply if the oxygen levels fall below a safe threshold, providing peace of mind for users.

Installation of the VFSM-30-3 is straightforward, with options for wall mounting or placing it on a hearth. This flexibility allows homeowners to integrate the fireplace into their existing décor seamlessly. Its variety of trim options and finishes further empowers users to personalize their fireplace, ensuring it complements their home’s interior design.

In summary, the Empire Comfort Systems VFSM-30-3 offers a reliable and stylish heating solution for those seeking the charm of a gas fireplace without the challenges of traditional venting. Its combination of efficiency, safety features, and customizable options makes it a remarkable choice for any home.