Empire Comfort Systems VFSM-30-3 installation instructions VFSR-16,18,24,30 Lighting Instructions

Page 13

VFSR-(16,18,24,30) LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch;

do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

Note: For easy access to valve for lighting pilot, remove branch log and middle log from burner assembly before lighting.

1.STOP! Read the safety information label.

2.Make sure the manual shutoff valve is fully open.

3.This gas log set is equipped with an ignition device (piezo) which lights the pilot. If piezo ignitor does not light the pilot, refer to Step 7.

4.Turn gas control knob clockwise to the “OFF” position, set the thermostat to the lowest setting and turn ON/OFF switch to OFF position.

5.Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas STOP! Follow “B” in the safety information label. If you do not smell gas, go to the next step.

6.From OFF position, turn the gas control knob counterclock-

wise to “Pilot” position. Push in and hold control knob for 5 seconds.

7.With the control knob pushed in, repeatedly push the piezo ig- nitor button until pilot is lit (or use a match to light pilot).

8.Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from shutting off the gas while the probe is warming up. Release the control knob.

9.Turn gas control knob counterclockwise to the “ON” position.

10.After the pilot has been lit for one minute, the burner can be turned on. Turn the ON/OFF switch to “ON” position or adjust thermostat to desired setting.

11.If the gas logs will not operate, follow the instructions “To Turn Off Gas To Appliance” and call your service technician or gas supplier.

Wait 30 seconds before readjusting the heater when the control knob has been turned down to a lower setting.

PIEZO

IGNITOR

HI/LO

REGULATOR

CONTROL

KNOB

TO TURN OFF GAS TO APPLIANCE

1. Turn control knob clockwise

to OFF position to

2. If applicable: Turn ON/OFF switch to OFF position and/or

completely shut off the heater.

 

set thermostat (if present) to lowest setting. If applicable:

 

 

Turn off all electric power to the heater.

18954-2-0107

Page 13

Image 13
Contents Millivolt Variable Manual Installation InstructionsTable of Contents Do not Tamper with Pilot Light Safety Important Safety InformationCarbon Monoxide Poisoning MAY Lead to DeathLP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction New InstallationBefore you get started General InformationMake sure you have received all parts Glass Doors ClearancesClearances Fireplace Preparation Combustible MaterialBefore Fully Installing the Appliance Installing AS a Vented ApplianceInstalling Damper Clamp Figure Pressure Testing of the Gas Supply System Installing a New Main Gas CockGAS Supply Recommended Gas Pipe DiameterOperation INSTRUCTIONS/FLAME Appearance Placement of Glowing Embers and Lava RockPlacing Lava Rock in Front of Burner on Fireplace Floor Variable Figure Millivolt Figure Manual FigureWhat to do if YOU Smell GAS VFSR-16,18,24,30 Lighting InstructionsLighting Instructions VFSM-18,24,30 Lighting Instructions Vfsr Pilot Pilot Flame CharacteristicsVfsv and Vfsm Pilot Correct Pilot Flame Pattern Incorrect Pilot Flame PatternTurn OFF Heater and Allow to Cool Before Cleaning Cleaning and ServicingVfsr WiringVfsv Heater produces a whistling noise when main burner is lit Gas odor even when control knob is in OFF positionNew Installation Appliance produces unwanted odorsIndex Part Description Parts ListParts View HOW to Order Repair Parts Service Notes Service Notes

VFSM-30-3 specifications

The Empire Comfort Systems VFSM-30-3 is a state-of-the-art vent-free gas fireplace that combines functionality with aesthetic appeal. Ideal for homes without traditional venting systems, this fireplace brings warmth and a cozy ambiance to any space while maintaining an efficient energy usage standard.

One of the main features of the VFSM-30-3 is its impressive heat output. With a heating capacity of up to 30,000 BTUs, it effectively warms areas up to 1,200 square feet, making it suitable for both small and large living spaces. The unit’s design incorporates a durable steel construction, ensuring longevity and resistance to wear over time.

The versatility of the Empire VFSM-30-3 is notable, as it can be powered by either natural gas or propane, allowing homeowners flexibility in fuel choice. It also features an adjustable flame height, giving users the option to create their desired level of warmth and ambiance. This is complemented by its realistic log set, which enhances the visual appeal, replicating the look of a traditional wood-burning fireplace.

Another significant characteristic of the VFSM-30-3 is its advanced vent-free technology. This innovative system allows for efficient combustion without the need for a chimney or flue, greatly reducing installation costs and complexities. The vent-free design also ensures that 100% of the heat generated is utilized within the room, providing exceptional energy efficiency.

Safety is a top priority with the Empire VFSM-30-3. The fireplace comes equipped with an oxygen depletion sensor, which automatically shuts off the gas supply if the oxygen levels fall below a safe threshold, providing peace of mind for users.

Installation of the VFSM-30-3 is straightforward, with options for wall mounting or placing it on a hearth. This flexibility allows homeowners to integrate the fireplace into their existing décor seamlessly. Its variety of trim options and finishes further empowers users to personalize their fireplace, ensuring it complements their home’s interior design.

In summary, the Empire Comfort Systems VFSM-30-3 offers a reliable and stylish heating solution for those seeking the charm of a gas fireplace without the challenges of traditional venting. Its combination of efficiency, safety features, and customizable options makes it a remarkable choice for any home.