Empire Comfort Systems VFSM-30-3 Installing AS a Vented Appliance, Installing Damper Clamp Figure

Page 10

INSTALLING AS A VENTED APPLIANCE

Notice: (Damper Clamp Installation)

When installing your log set as a vented installation the damper clamp must be used.

When installing your log set as a vent-free installation the damper clamp can be used to eliminate the potential for odors when burning the logs for the first time.

Installing Damper Clamp (Figure 9)

Remove all ashes or other debris from the fireplace. If the fireplace is equipped with an ash dump be sure to seal the door with furnace cement or high temperature silicone. Be sure to check the damper for proper operation and verify that the flue passageway is open.

Place the clamp over the lip of the damper and tighten the hold down bolt until the clamp is securely attached to the damper. This will prevent the damper from accidentally closing.

Manual and millivolt controlled gas logs may be installed as a vented decorative log set in compliance with ANSI Z21.60 and National Fuel Gas Code. When the gas logs are operated with the damper open, non-combustible material and minimum mantel requirements do not apply.

Figure 9

BEFORE FULLY INSTALLING THE APPLIANCE

Turn off the gas supply to the fireplace or firebox.

Seal any fresh air vents and/or ash clean-out doors located on the floor or wall of the fireplace. If left unsealed, drafting may cause pilot outage or sooting. Use a heat resistant sealant. Do not seal the chimney flue damper.

Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner.

You must secure the gas log heater to the fireplace floor. If not, the entire unit may move when you adjust the controls. Movement of unit may cause shifting of the gas logs which leads to sooting and improper burning. Grate movement could cause a gas leak.

Special care is required if you are installing the unit into a sunken fireplace. You must raise the fireplace floor to allow access to gas log controls. This will insure adequate air flow and guard against sooting. Raise the fireplace floor using noncombustible materials.

Assembly Procedure: (Figure 10)

1.Center the gas log unit in the fireplace or firebox. Make certain the front feet of the grate sit inside the front edge of the fireplace or firebox.

2.An anchor hole is provided in the two bottom side members of the grate frame. After centering the grate correctly, mark the hole positions on the fireplace/firebox floor. Drill two (2) 5/32" diameter holes approximately 1-1/2" deep for masonry screws or 1/8" hole for sheet metal screws.

3.Anchor the grate to the fireplace/firebox floor using the screws provided. Refer to Figure10.

Proper installation of the grate is essential to prevent any move- ment of the gas logs and controls during operation.

Figure 10

Page 10

18954-2-0107

Image 10
Contents Installation Instructions Millivolt Variable ManualTable of Contents Carbon Monoxide Poisoning MAY Lead to Important Safety InformationDo not Tamper with Pilot Light Safety DeathSafety Information for Users of LP-GAS LP-GAS Warning OdorNew Installation IntroductionBefore you get started General InformationMake sure you have received all parts Clearances Glass DoorsClearances Combustible Material Fireplace PreparationBefore Fully Installing the Appliance Installing AS a Vented ApplianceInstalling Damper Clamp Figure GAS Supply Installing a New Main Gas CockPressure Testing of the Gas Supply System Recommended Gas Pipe DiameterPlacing Lava Rock in Front of Burner on Fireplace Floor Placement of Glowing Embers and Lava RockOperation INSTRUCTIONS/FLAME Appearance Variable Figure Millivolt Figure Manual FigureVFSR-16,18,24,30 Lighting Instructions What to do if YOU Smell GASLighting Instructions VFSM-18,24,30 Lighting Instructions Vfsv and Vfsm Pilot Pilot Flame CharacteristicsVfsr Pilot Correct Pilot Flame Pattern Incorrect Pilot Flame PatternCleaning and Servicing Turn OFF Heater and Allow to Cool Before CleaningVfsr WiringVfsv New Installation Gas odor even when control knob is in OFF positionHeater produces a whistling noise when main burner is lit Appliance produces unwanted odorsParts List Index Part DescriptionParts View HOW to Order Repair Parts Service Notes Service Notes

VFSM-30-3 specifications

The Empire Comfort Systems VFSM-30-3 is a state-of-the-art vent-free gas fireplace that combines functionality with aesthetic appeal. Ideal for homes without traditional venting systems, this fireplace brings warmth and a cozy ambiance to any space while maintaining an efficient energy usage standard.

One of the main features of the VFSM-30-3 is its impressive heat output. With a heating capacity of up to 30,000 BTUs, it effectively warms areas up to 1,200 square feet, making it suitable for both small and large living spaces. The unit’s design incorporates a durable steel construction, ensuring longevity and resistance to wear over time.

The versatility of the Empire VFSM-30-3 is notable, as it can be powered by either natural gas or propane, allowing homeowners flexibility in fuel choice. It also features an adjustable flame height, giving users the option to create their desired level of warmth and ambiance. This is complemented by its realistic log set, which enhances the visual appeal, replicating the look of a traditional wood-burning fireplace.

Another significant characteristic of the VFSM-30-3 is its advanced vent-free technology. This innovative system allows for efficient combustion without the need for a chimney or flue, greatly reducing installation costs and complexities. The vent-free design also ensures that 100% of the heat generated is utilized within the room, providing exceptional energy efficiency.

Safety is a top priority with the Empire VFSM-30-3. The fireplace comes equipped with an oxygen depletion sensor, which automatically shuts off the gas supply if the oxygen levels fall below a safe threshold, providing peace of mind for users.

Installation of the VFSM-30-3 is straightforward, with options for wall mounting or placing it on a hearth. This flexibility allows homeowners to integrate the fireplace into their existing décor seamlessly. Its variety of trim options and finishes further empowers users to personalize their fireplace, ensuring it complements their home’s interior design.

In summary, the Empire Comfort Systems VFSM-30-3 offers a reliable and stylish heating solution for those seeking the charm of a gas fireplace without the challenges of traditional venting. Its combination of efficiency, safety features, and customizable options makes it a remarkable choice for any home.