Lincoln Electric IM644-A manual Installation, Bore x Stroke, HEIGHT2 Width Depth Weight

Models: IM644-A

1 54
Download 54 pages 28.19 Kb
Page 9
Image 9

A-1

 

INSTALLATION

 

A-1

 

 

 

 

 

TECHNICAL SPECIFICATIONS - Commander 500 (K1639-1 & -2)

 

 

INPUT - DIESEL ENGINE

 

 

 

 

 

 

Make/Model

Description

Speed (RPM)

Displacement

Starting

Capacities

 

 

 

 

System

 

 

 

 

 

 

 

Deutz

3 cylinder

High Idle 1900

173 cu. in

12VDC battery

Fuel: 25 gal.

F3L 912

44 HP(33 kw)

Low Idle 1400

(2.83 L)

& Starter

94.6 L

Diesel Engine

@ 1800 RPM

Full Load 1800

 

 

 

Bore x Stroke

 

Oil: 9.5 Qts.

 

 

 

 

 

 

 

 

 

9.0 L

 

 

 

3.94” x 4.72”

 

 

 

 

 

(100mm x 120mm)

 

 

 

 

 

 

 

 

RATED OUTPUT - WELDER

Duty Cycle

 

Welding Output

 

 

 

Volts at Rated Amps

 

100%

 

 

500 Amps (DC multi-purpose)

 

 

 

40 Volts

 

 

 

 

 

 

 

 

 

 

 

 

60%

 

 

550 Amps (DC multi-purpose)

 

 

 

36 Volts

 

 

 

 

 

 

 

 

 

 

 

 

50%

 

 

575 Amps (DC multi-purpose)

 

 

 

35 Volts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT - WELDER AND GENERATOR

 

Welding Range

 

Open Circuit Voltage

 

 

Auxiliary Power1

 

30 - 575 Amps CC/CV

 

90 Max OCV

 

 

 

120/240 VAC

 

 

 

 

 

 

 

 

 

12,000 Watts, 60 Hz.

 

15 - 200 Amps TIG

 

@1900 RPM

 

 

100% Duty Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEIGHT2

 

WIDTH

 

DEPTH

 

 

WEIGHT

 

42.0 in.

 

31.5 in.

 

63.1 in.

 

 

1640 lbs.(744 kg)

 

 

 

 

 

 

 

 

 

 

 

( Approx.)

 

1066.8 mm

 

800.1 mm

 

1602.7 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Output rating in watts is equivalent to volt-amperes at unity power factor.

Output voltage is within +/- 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.

2. Top of Enclosure. Add 8.9” (226.1mm) for exhaust.

COMMANDER 500

Page 9
Image 9
Lincoln Electric IM644-A manual Installation, Bore x Stroke, Duty Cycle Welding Output Volts at Rated Amps