Empire Comfort Systems P)-2, DVP42FP VERTICAL, 90 Elbow to Horizontal OUT the Wall, Model

Page 14

INSTALLATION (continued)

HORIZONTAL ONLY, STRAIGHT OUT THE BACK

CORNER INSTALLATION VERTICAL, 90° ELBOW TO

"A"

HORIZONTAL OUT THE WALL

WALL FIRESTOP/

PIPE LENGTH

THIMBLE

VENT

CAP

VENT CAP

WALL FIRESTOP/

THIMBLE

"A"

 

"B"

MODEL

6"(152mm)

5

1/8"(130mm) to 6 /2"(165mm)

DVP 42,48

9"(229mm)

8

1/8"(206mm) to 91/2"(241mm)

DVP 42

12"(305mm)

11 1/8"(283mm) to 12 1/2"(317mm)

DVP 42

Figure 15

VERTICAL, 90° ELBOW TO

HORIZONTAL OUT THE WALL

WALL FIRESTOP

THIMBLE

"A"

 

"B"

 

 

"C"

6"(152mm)

11 1/4"(286mm) to

4

3/4"(121mm) to

 

12

3/4"(324mm)

6

1/4"(159mm)

9"(229mm)

14

1/4"(362mm) to

7

3/4"(197mm) to

 

15

3/4"(400mm)

9

1/4"(235MM)

 

 

 

 

 

12"(305mm)

17

1/4"(438mm) to

10

3/4"(273mm) to

 

18

3/4"(476mm)

12

1/4"(311mm)

 

 

 

 

 

 

Figure 16

Dim.

DVP42

DVP48

 

 

 

A

45 3/8"

49 5/8"

1152mm

1260mm

 

 

 

 

B

32 1/8"

35 1/8"

816mm

892mm

 

 

 

 

C

13 3/8"

15 1/2"

34 mm

39 mm

 

 

 

 

D

64 1/8"

70 1/8"

1628mm

1781mm

 

 

 

 

Figure 17

CORNER INSTALLATION HORIZONTAL, 45° ELBOW

TO HORIZONTAL OUT THE WALL

WALL FIRESTOP/

THIMBLE

 

DVP42

DVP48

"A"

"B"

"B"

6"(152mm)

4"(102mm) to

4"(102mm) to

 

5 1/2"(140mm)

5"(127mm)

9"(229mm)

6"(152mm) to

6"(152mm) to

 

7 /2"(191mm)

7 1/2"(191mm)

12"(305mm)

9"(229mm) to

9"(229mm) to

 

10 1/2"(267mm)

10 1/2"(267mm)

Figure 18

Page 14

21759-6-0608

Image 14
Contents Remote RF Models Millivolt Standing PilotIntermittent Pilot UL File NO. MH30033Table of Contents Important Safety Information Some Points to Remember LP-GAS Warning OdorNo Odor Detected Odor Fade Requirements for Massachusetts Vent Directly BELOW. Keep Clear of ALL ObstructionsIntroduction Remote Control Options Description SpecificationsFireplace Dimensions DVP42 DVP48Clearances Figure ClearancesLocating Fireplace Combustible MaterialChecking Manifold Pressures Installing a New Main Gas CockGAS Supply Rear Vent Conversion Converting flue take-off to rear ventingVent Pipe Clearance InstallationFraming and Finishing Finishing Figures 12 Flush Mount Mantel Installation FigureFraming Figure Vent Runs Figures 14, 15, 16, 17 Flush Wall InstallationCombustible Surround Installation VERTICAL, 90 Elbow with Horizontal TerminationVERTICAL, 90 Elbow to Horizontal OUT the Wall ModelExample a Venting Fireplace TOPTo Use the Vent Graph Figure Example BBelow Grade Installation Typical Basement InstallationPositioning the Fireplace Cutting the Hole FiguresExamples TOP Vent RUN Venting Examples When Using DVA47 Adaptor Vertically Off Top of Fireplace OnlyInstallation Instructions DVVK-4FV Direct Vent Termination KITInstallation Note Items Required For Installation Tools Building SuppliesInstallation of the Vertical Flex Termination Kit Before You StartStep-By-Step Installation For Flex DV Kit Roof Pitch DIA. Flex AIR Intake Pipe 35 ft. Max Quantity Number Item Description Repair Part No SuppliedDimensions in Feet Venting Fireplace RearExamples Rear Vent RUN Parts Verification DVVK-4RE Vent KIT Installation InstructionsInstalling Wall Thimble/Firestop Assembly DVVK-4RE Vent KIT Installation Instructions Sealing 4 102mm Diameter Flue Outlet TubeParts List Connecting to Rigid Vent SystemInstallation DVVK-4F Flex Vent Instructions TOP Vent onlyInformation on Various Venting Routes and Components Vertical Sidewall InstallationsTermination Clearances Vent Clearances Vent System Identification Special Venting Components Simpson DuraventInstalling Vent Components Figure DVVK-5RPInstalling Support Brackets Figure Venting Framing and FinishingSee Horizontal Termination Page 41 and Vertical Termination Installing Firestops Figures 64, 65, 66 ⅝ Venting Framing and Finishing⅝ Venting Framing and Finishing Horizontal Termination Installation DVVK-5F Flex Vent InstructionsVertical Termination General MaintenanceSee Figure Installing the Vent System in a Chase Determining Minimum Vent Height Above the RoofReassembly and Resealing Vent Pipe System Vertical TerminationLOG Placement 4 LOG SET Initial Lighting Operating InstructionsMillivolt System Pilot Flame FigureTRW Standing Pilot Wiring Diagram Lighting Instructions For Your SAFETY, Read Before LightingStanding Pilot Lighting Instructions To Turn OFF GAS to FireplacePilot and main burner extinguish while in operation Standing Pilot TroubleshootingFrequent pilot outage problem Glass sootsElectrical Connection Figure Intermittent Pilot Wiring DiagramIntermittent Pilot Operating Instructions Damage, personal injury or loss of life Intermittent Pilot Lighting InstructionsTo Turn OFF GAS to Appliance Checkout Intermittent Pilot TroubleshootingS8600H Intermittent Ignition Module Specifications OperationSafety Lockout Main Burner OperationIgnition System Checks Check ignition cable. Make sure ARC Length ActionIntermittent Pilot Troubleshooting Green LED Status Codes RF Standing Pilot Operating Instructions RF Transmitter Functions Status ActionWiring Diagram with Blower RF Wiring DiagramWhat to do if YOU Smell GAS For Your Safety Read Before LightingRF Standing Pilot Lighting Instructions Maintenance and Service Parts View Parts List Index Part Number Description DVP42 DVP48Parts List Blower Wheels FBB4 Optional Variable Speed Blower InstallationBlower Motor Volt AC Junction BOX Wiring Installation Instructions Optional Brick Liner Installation InstructionsAccessories FBB4Service Notes HOW to Order Repair Parts Service Notes

DVP42FP, P)-2 specifications

Empire Comfort Systems has established itself as a leader in the heating and venting industry, providing innovative solutions that cater to modern home heating needs. One of their standout products is the Empire Comfort Systems DVP42FP,P)-2, a direct vent gas fireplace that seamlessly combines aesthetics, efficiency, and technology.

At the heart of the DVP42FP,P)-2 is its contemporary design, which enhances the ambiance of any living space. With a sleek glass front and a range of stylish finishes, this fireplace serves as a perfect centerpiece, embodying both function and fashion. The generous viewing area allows for an unobstructed view of the mesmerizing flames, creating a cozy atmosphere in any room.

This fireplace is engineered for efficiency and performance. With an impressive heating output, the DVP42FP,P)-2 can effectively warm spaces while consuming minimal fuel. It boasts a high-efficiency rating, ensuring that homeowners can enjoy the warmth without incurring high energy costs. The direct vent technology allows for a sealed combustion system that draws air from outside while expelling exhaust gases directly outdoors. This ensures that the air quality inside the home is maintained while providing optimal heating performance.

Ease of use is another hallmark of the DVP42FP,P)-2. It features an intuitive remote control system, allowing users to adjust the temperature and flame settings conveniently from anywhere in the room. This level of user-friendly control enhances the overall experience, making it easy to create the perfect environment.

Another notable characteristic of this model is its safety features. Equipped with safety screens and an auto shut-off feature, the DVP42FP,P)-2 is designed to offer peace of mind, allowing families to enjoy their fireplace without worries about safety.

Maintenance is straightforward with the DVP42FP,P)-2, thanks to its accessible design. Regular upkeep is minimal, allowing homeowners to spend more time enjoying the warmth and beauty of their fireplace rather than worrying about system maintenance.

In conclusion, the Empire Comfort Systems DVP42FP,P)-2 is a captivating, efficient, and technologically advanced direct vent gas fireplace. With its modern design, high efficiency, user-friendly controls, and robust safety features, it represents a wise investment for anyone looking to enhance their home's comfort and aesthetic appeal. Whether for a new build or a renovation, this fireplace stands out as a premier choice for discerning homeowners.