JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS

CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND STATE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THAT MAIN POWER SUPPLY IS DISCONNECTED. THE APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES,

WITH THE NATIONAL ELECTRICAL CODE ANSI/NFPA 70 (LATEST EDITION).

*

A factory installed junction box is located on the lower right side of the

 

fireplace. Wiring must be fed to the junction box and attached to the

 

receptacle that is provided. Leave approximately 6" of wire in the junction

 

box for connection.

 

Attach black wire to one side of the receptacle and white wire to opposite

 

side of receptacle. The ground wire should be attached to the green

 

(ground) screw.

Install the receptacle into the junction box. Attach cover plate.

Figure 88

*Note: For intermittent pilot models, refer to wiring instructions on page 51.

OPTIONAL BRICK LINER INSTALLATION INSTRUCTIONS

1.Using gloves, unpack liner components and check for damaged or missing components.

2.Lower bottom louver and remove upper louver on fireplace.

3.Remove glass frame assembly from fireplace.

4.Remove rear logs from burner assembly.

5.Place brick panel (rear) against rear wall in fireplace.

Note: The top edge will have a half-moon cutout relief to match up with the rear flue vent hole.

6.While holding finished edge on brick panel (side), place brick panel (sides) against side walls in fireplace. Move side panels rearward until the back edge meets the rear brick panel. Slide side brick panels down so they rest on firebox bottom.

7.Align grout lines on top brick panel with the grout lines on the side brick panels. Place the top brick panel into brick panel holder. With needle-nose pliers, carefully bend hold-down tabs on brick panel holder over the edges of the top brick panel. The hold-down tabs will securely hold the top brick panel in place.

8.Replace rear logs onto burner assembly. (Refer to log placement, page 45.)

9.Attach glass frame assembly onto fireplace.

10.Raise bottom louver and replace top louver onto fireplace.

11.Installation of optional brick liner is complete.

Page 68

21759-6-0608

Image 68
Contents Millivolt Standing Pilot Intermittent PilotRemote RF Models UL File NO. MH30033Table of Contents Important Safety Information Some Points to Remember LP-GAS Warning OdorNo Odor Detected Odor Fade Requirements for Massachusetts Vent Directly BELOW. Keep Clear of ALL ObstructionsIntroduction Specifications Fireplace DimensionsRemote Control Options Description DVP42 DVP48Clearances Locating FireplaceClearances Figure Combustible MaterialChecking Manifold Pressures Installing a New Main Gas CockGAS Supply Rear Vent Conversion Converting flue take-off to rear ventingVent Pipe Clearance InstallationFraming and Finishing Finishing Figures 12 Flush Mount Mantel Installation FigureFraming Figure Flush Wall Installation Combustible Surround InstallationVent Runs Figures 14, 15, 16, 17 VERTICAL, 90 Elbow with Horizontal TerminationVERTICAL, 90 Elbow to Horizontal OUT the Wall ModelVenting Fireplace TOP To Use the Vent Graph FigureExample a Example BBelow Grade Installation Typical Basement InstallationPositioning the Fireplace Cutting the Hole FiguresExamples TOP Vent RUN Venting Examples When Using DVA47 Adaptor Vertically Off Top of Fireplace OnlyInstallation Instructions DVVK-4FV Direct Vent Termination KITItems Required For Installation Tools Building Supplies Installation of the Vertical Flex Termination KitInstallation Note Before You StartStep-By-Step Installation For Flex DV Kit Roof Pitch DIA. Flex AIR Intake Pipe 35 ft. Max Quantity Number Item Description Repair Part No SuppliedDimensions in Feet Venting Fireplace RearExamples Rear Vent RUN Parts Verification DVVK-4RE Vent KIT Installation InstructionsInstalling Wall Thimble/Firestop Assembly DVVK-4RE Vent KIT Installation Instructions Sealing 4 102mm Diameter Flue Outlet TubeParts List Connecting to Rigid Vent SystemInstallation DVVK-4F Flex Vent Instructions TOP Vent onlyInformation on Various Venting Routes and Components Vertical Sidewall InstallationsTermination Clearances Vent Clearances Vent System Identification Special Venting Components Simpson DuraventInstalling Vent Components Figure DVVK-5RPInstalling Support Brackets Figure Venting Framing and FinishingSee Horizontal Termination Page 41 and Vertical Termination Installing Firestops Figures 64, 65, 66 ⅝ Venting Framing and Finishing⅝ Venting Framing and Finishing Horizontal Termination Installation DVVK-5F Flex Vent InstructionsGeneral Maintenance See Figure Installing the Vent System in a ChaseVertical Termination Determining Minimum Vent Height Above the RoofReassembly and Resealing Vent Pipe System Vertical TerminationLOG Placement 4 LOG SET Operating Instructions Millivolt SystemInitial Lighting Pilot Flame FigureTRW Standing Pilot Wiring Diagram For Your SAFETY, Read Before Lighting Standing Pilot Lighting InstructionsLighting Instructions To Turn OFF GAS to FireplaceStanding Pilot Troubleshooting Frequent pilot outage problemPilot and main burner extinguish while in operation Glass sootsElectrical Connection Figure Intermittent Pilot Wiring DiagramIntermittent Pilot Operating Instructions Damage, personal injury or loss of life Intermittent Pilot Lighting InstructionsTo Turn OFF GAS to Appliance Intermittent Pilot Troubleshooting S8600H Intermittent Ignition Module SpecificationsCheckout OperationSafety Lockout Main Burner OperationIgnition System Checks Check ignition cable. Make sure ARC Length ActionIntermittent Pilot Troubleshooting Green LED Status Codes RF Standing Pilot Operating Instructions RF Transmitter Functions Status ActionWiring Diagram with Blower RF Wiring DiagramWhat to do if YOU Smell GAS For Your Safety Read Before LightingRF Standing Pilot Lighting Instructions Maintenance and Service Parts View Parts List Index Part Number Description DVP42 DVP48Parts List Blower Wheels FBB4 Optional Variable Speed Blower InstallationBlower Motor Volt AC Junction BOX Wiring Installation Instructions Optional Brick Liner Installation InstructionsAccessories FBB4Service Notes HOW to Order Repair Parts Service Notes

DVP42FP, P)-2 specifications

Empire Comfort Systems has established itself as a leader in the heating and venting industry, providing innovative solutions that cater to modern home heating needs. One of their standout products is the Empire Comfort Systems DVP42FP,P)-2, a direct vent gas fireplace that seamlessly combines aesthetics, efficiency, and technology.

At the heart of the DVP42FP,P)-2 is its contemporary design, which enhances the ambiance of any living space. With a sleek glass front and a range of stylish finishes, this fireplace serves as a perfect centerpiece, embodying both function and fashion. The generous viewing area allows for an unobstructed view of the mesmerizing flames, creating a cozy atmosphere in any room.

This fireplace is engineered for efficiency and performance. With an impressive heating output, the DVP42FP,P)-2 can effectively warm spaces while consuming minimal fuel. It boasts a high-efficiency rating, ensuring that homeowners can enjoy the warmth without incurring high energy costs. The direct vent technology allows for a sealed combustion system that draws air from outside while expelling exhaust gases directly outdoors. This ensures that the air quality inside the home is maintained while providing optimal heating performance.

Ease of use is another hallmark of the DVP42FP,P)-2. It features an intuitive remote control system, allowing users to adjust the temperature and flame settings conveniently from anywhere in the room. This level of user-friendly control enhances the overall experience, making it easy to create the perfect environment.

Another notable characteristic of this model is its safety features. Equipped with safety screens and an auto shut-off feature, the DVP42FP,P)-2 is designed to offer peace of mind, allowing families to enjoy their fireplace without worries about safety.

Maintenance is straightforward with the DVP42FP,P)-2, thanks to its accessible design. Regular upkeep is minimal, allowing homeowners to spend more time enjoying the warmth and beauty of their fireplace rather than worrying about system maintenance.

In conclusion, the Empire Comfort Systems DVP42FP,P)-2 is a captivating, efficient, and technologically advanced direct vent gas fireplace. With its modern design, high efficiency, user-friendly controls, and robust safety features, it represents a wise investment for anyone looking to enhance their home's comfort and aesthetic appeal. Whether for a new build or a renovation, this fireplace stands out as a premier choice for discerning homeowners.