Empire Comfort Systems P)-2 FBB4 Optional Variable Speed Blower Installation, Blower Motor

Page 66

FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION

Attention: Install blower assembly before connecting gas inlet supply line

Note: Junction box on right side of fireplace must be pre-wired at time of fireplace installation for use with blower assembly. It is recommended that an ON/OFF wall switch be installed that will activate the power supply to the furnace by a qualified electrician.

1.If installed, turn OFF gas supply to fireplace.

2.If applicable, turn OFF electric supply to fireplace.

3.Lower bottom louver on fireplace.

4.Refer to page 68, "Junction Box Wiring Installation Instructions" to complete wiring of junction box.

Attention: If installed, do not damage gas inlet supply line when blower assembly is inserted into fireplace. If necessary, remove gas inlet supply line.

Wiring

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. For an ungrounded receptacle, an adapter, which has two prongs and a wire for grounding, can be purchased, plugged into the ungrounded receptacle and its wire connected to the receptacle mounting screw. With this wire completing the ground, the appliance cord plug can be plugged into the adapter and be electrically grounded.

Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

Blower Motor

The blower motor does not have oiling holes. Do not attempt to oil the blower motor.

Blower Wheels

The blower wheels will collect lint and could require periodic cleaning. If the air output decreases or the noise level increases, it indicates a dirty blower wheel. Remove fan and clean blower wheels.

Warning: Unplugging of blower accessory will not stop the heater from cycling. To turn off gas to the heater (millivolt model): push in gas control knob slightly and turn clockwise to "OFF." Do not force. To turn off gas on direct ignition model, turn gas line valve to "OFF."

5.Insert blower assembly into interior, bottom of fireplace. Position blower assembly behind gas valve, align notch on back of blower assembly with center screw on fireplace back and push blower assembly against fireplace back. The magnets on the back and bottom of blower assembly will sufficiently hold blower assembly in place.

6.Position speed control box to the right of gas valve. Attach speed control box to bottom of fireplace. The magnets on bottom of speed control box will sufficiently hold speed control box in place.

7.With base (flush face) of fan control switch facing upward, insert base of fan control switch under the mounting tabs on valve bracket. The base (flush face) of fan control switch must be in contact with bottom of firebox.

8.Insert power cord plug into junction box.

9.Close bottom louver on fireplace.

10.Installation of FBB4 optional variable speed blower assembly is completed.

SEE NOTE*

 

JUNCTION BOX

FAN KIT

SPEED CONTROL

 

VALVE BRACKET

 

FAN SWITCH

 

 

SWITCH HOLDER

(TOP OF VALVE BRACKET)

*Note: Refer to Junction Box wiring instructions on page 68 for proper operation.

Figure 87

Page 66

21759-6-0608

Image 66
Contents Remote RF Models Millivolt Standing PilotIntermittent Pilot UL File NO. MH30033Table of Contents Important Safety Information LP-GAS Warning Odor No Odor Detected Odor FadeSome Points to Remember Requirements for Massachusetts Vent Directly BELOW. Keep Clear of ALL ObstructionsIntroduction Remote Control Options Description SpecificationsFireplace Dimensions DVP42 DVP48Clearances Figure ClearancesLocating Fireplace Combustible MaterialInstalling a New Main Gas Cock GAS SupplyChecking Manifold Pressures Rear Vent Conversion Converting flue take-off to rear ventingInstallation Framing and FinishingVent Pipe Clearance Flush Mount Mantel Installation Figure Framing FigureFinishing Figures 12 Vent Runs Figures 14, 15, 16, 17 Flush Wall InstallationCombustible Surround Installation VERTICAL, 90 Elbow with Horizontal TerminationVERTICAL, 90 Elbow to Horizontal OUT the Wall ModelExample a Venting Fireplace TOPTo Use the Vent Graph Figure Example BBelow Grade Installation Typical Basement InstallationPositioning the Fireplace Cutting the Hole FiguresExamples TOP Vent RUN Venting Examples When Using DVA47 Adaptor Vertically Off Top of Fireplace OnlyInstallation Instructions DVVK-4FV Direct Vent Termination KITInstallation Note Items Required For Installation Tools Building SuppliesInstallation of the Vertical Flex Termination Kit Before You StartStep-By-Step Installation For Flex DV Kit Roof Pitch DIA. Flex AIR Intake Pipe 35 ft. Max Quantity Number Item Description Repair Part No SuppliedDimensions in Feet Venting Fireplace RearExamples Rear Vent RUN DVVK-4RE Vent KIT Installation Instructions Installing Wall Thimble/Firestop AssemblyParts Verification DVVK-4RE Vent KIT Installation Instructions Sealing 4 102mm Diameter Flue Outlet TubeParts List Connecting to Rigid Vent SystemInstallation DVVK-4F Flex Vent Instructions TOP Vent onlyVertical Sidewall Installations Termination ClearancesInformation on Various Venting Routes and Components Vent Clearances Vent System Identification Special Venting Components Simpson DuraventInstalling Vent Components Figure DVVK-5RPInstalling Support Brackets Figure Venting Framing and FinishingSee Horizontal Termination Page 41 and Vertical Termination Installing Firestops Figures 64, 65, 66 ⅝ Venting Framing and Finishing⅝ Venting Framing and Finishing Horizontal Termination Installation DVVK-5F Flex Vent InstructionsVertical Termination General MaintenanceSee Figure Installing the Vent System in a Chase Determining Minimum Vent Height Above the RoofReassembly and Resealing Vent Pipe System Vertical TerminationLOG Placement 4 LOG SET Initial Lighting Operating InstructionsMillivolt System Pilot Flame FigureTRW Standing Pilot Wiring Diagram Lighting Instructions For Your SAFETY, Read Before LightingStanding Pilot Lighting Instructions To Turn OFF GAS to FireplacePilot and main burner extinguish while in operation Standing Pilot TroubleshootingFrequent pilot outage problem Glass sootsIntermittent Pilot Wiring Diagram Intermittent Pilot Operating InstructionsElectrical Connection Figure Intermittent Pilot Lighting Instructions To Turn OFF GAS to ApplianceDamage, personal injury or loss of life Checkout Intermittent Pilot TroubleshootingS8600H Intermittent Ignition Module Specifications OperationSafety Lockout Main Burner OperationIgnition System Checks Check ignition cable. Make sure ARC Length ActionIntermittent Pilot Troubleshooting Green LED Status Codes RF Standing Pilot Operating Instructions RF Transmitter Functions Status ActionWiring Diagram with Blower RF Wiring DiagramFor Your Safety Read Before Lighting RF Standing Pilot Lighting InstructionsWhat to do if YOU Smell GAS Maintenance and Service Parts View Parts List Index Part Number Description DVP42 DVP48Parts List FBB4 Optional Variable Speed Blower Installation Blower MotorBlower Wheels Volt AC Junction BOX Wiring Installation Instructions Optional Brick Liner Installation InstructionsAccessories FBB4Service Notes HOW to Order Repair Parts Service Notes

DVP42FP, P)-2 specifications

Empire Comfort Systems has established itself as a leader in the heating and venting industry, providing innovative solutions that cater to modern home heating needs. One of their standout products is the Empire Comfort Systems DVP42FP,P)-2, a direct vent gas fireplace that seamlessly combines aesthetics, efficiency, and technology.

At the heart of the DVP42FP,P)-2 is its contemporary design, which enhances the ambiance of any living space. With a sleek glass front and a range of stylish finishes, this fireplace serves as a perfect centerpiece, embodying both function and fashion. The generous viewing area allows for an unobstructed view of the mesmerizing flames, creating a cozy atmosphere in any room.

This fireplace is engineered for efficiency and performance. With an impressive heating output, the DVP42FP,P)-2 can effectively warm spaces while consuming minimal fuel. It boasts a high-efficiency rating, ensuring that homeowners can enjoy the warmth without incurring high energy costs. The direct vent technology allows for a sealed combustion system that draws air from outside while expelling exhaust gases directly outdoors. This ensures that the air quality inside the home is maintained while providing optimal heating performance.

Ease of use is another hallmark of the DVP42FP,P)-2. It features an intuitive remote control system, allowing users to adjust the temperature and flame settings conveniently from anywhere in the room. This level of user-friendly control enhances the overall experience, making it easy to create the perfect environment.

Another notable characteristic of this model is its safety features. Equipped with safety screens and an auto shut-off feature, the DVP42FP,P)-2 is designed to offer peace of mind, allowing families to enjoy their fireplace without worries about safety.

Maintenance is straightforward with the DVP42FP,P)-2, thanks to its accessible design. Regular upkeep is minimal, allowing homeowners to spend more time enjoying the warmth and beauty of their fireplace rather than worrying about system maintenance.

In conclusion, the Empire Comfort Systems DVP42FP,P)-2 is a captivating, efficient, and technologically advanced direct vent gas fireplace. With its modern design, high efficiency, user-friendly controls, and robust safety features, it represents a wise investment for anyone looking to enhance their home's comfort and aesthetic appeal. Whether for a new build or a renovation, this fireplace stands out as a premier choice for discerning homeowners.