Empire Comfort Systems P)-2, DVP42FP installation instructions Introduction

Page 6
*Available from the American National Standards Institute, Inc. 11 West 42nd

INTRODUCTION

Instructions to Installer

1.Installer must leave instruction manual with owner after installation.

2.Installer must have owner fill out and mail warranty card supplied with the fireplace.

3.Installer should show owner how to start and operate the fireplace.

This direct vent gas fireplace heater is designed to operate with all combustion air being siphoned from the outside of the building and all exhaust gases expelled to the outside of the building. The information contained in this manual pertains to all models and gas control systems unless otherwise noted.

Warning: This unit is not for use with solid fuels. Appliance Certification

This fireplace is design certified in accordance with American National Standard/CSA Standard ANSI Z.21-88/CSA 2.33 and by Underwriters Laboratories as a Direct Vent Gas Fireplace Heater and shall be installed according to these instructions.

Consult your local building code agency, prior to installation, to ensure compliance with local codes-including permits and inspections.

The fireplace, when installed, must be electrically grounded in accordance with local codes or, in absence of local codes, with the National Electric Code ANSI/NFPA 70 or Canadian Electric code, CSA C22.1, if an external electrical source is utilized.

These models may be installed in a bedroom or bed-sitting room in the U.S.A. and Canada.

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term “qualified agency” means any individual, firm, corporation or company which either in person or through a representative is engaged in and is responsible for (a) the installation or replacement of gas piping or (b) the connection, installation, repair or servicing of equipment, who is experienced in such work, familiar with all precautions required and has complied with all the requirements of the authority having jurisdiction.

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 54* Natural Gas and Propane Installation Code, or CSA B149.1 in Canada.

St., New York, N.Y. 10036.

Warning: ANY CHANGE TO THIS FIREPLACE OR ITS CONTROLS CAN BE DANGEROUS.

Improper installation or use of the fireplace can cause serious injury or death from fire, burns, explosions, or carbon monoxide poisoning.

Any alteration of the original design, installed other than as shown in these instructions oruse with a type of gas not shown on the rating plate is the responsibility of the person and company making the change.

Important

All correspondence should refer to complete Model Number, Serial Number and type of gas.

High Altitude

When installing this unit at an elevation above 2000 feet (in the United States) it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Generally, input should be reduced 4 percent for each 1000 feet above sea level. However, if the heating value of the gas has been reduced, this general rule may not apply. Check with local gas utility for proper orifice size identification.

Canadian High Altitude Altitude: 0-4500 feet (0-1370 m)

When installing this unit at an elevation above 4500 feet (in Canada), check with local authorities.

Consult your local gas utility for assistance in determining the proper orifice for location.

Preparation

This direct vent gas fireplace and its components are tested and safe when installed in accordance with this Installation Manual. Report to your dealer any parts damaged in shipment, specifically check glass condition. Do not install unit with damaged, incomplete, or substitute parts. Read all instructions before starting installation and follow these instructions carefully during installation to insure maximum benefit and safety. Failure to follow them will void your warranty and may present a fire hazard.

The warranty will be voided by, and the warranter disclaims any responsibility for the following actions:

Installation of any damaged fireplace or vent system component.

Modification of the fireplace or direct vent system.

Installation other than as instructed by Empire Comfort Systems, Inc.

Improper positioning of the logs, glass door or decorative rock.

Installation and/or use of any component part not manufactured or approved by manufacturer.

Page 6

21759-6-0608

Image 6
Contents Remote RF Models Millivolt Standing PilotIntermittent Pilot UL File NO. MH30033Table of Contents Important Safety Information LP-GAS Warning Odor No Odor Detected Odor FadeSome Points to Remember Requirements for Massachusetts Vent Directly BELOW. Keep Clear of ALL ObstructionsIntroduction Remote Control Options Description SpecificationsFireplace Dimensions DVP42 DVP48Clearances Figure ClearancesLocating Fireplace Combustible MaterialInstalling a New Main Gas Cock GAS SupplyChecking Manifold Pressures Rear Vent Conversion Converting flue take-off to rear ventingInstallation Framing and FinishingVent Pipe Clearance Flush Mount Mantel Installation Figure Framing FigureFinishing Figures 12 Vent Runs Figures 14, 15, 16, 17 Flush Wall InstallationCombustible Surround Installation VERTICAL, 90 Elbow with Horizontal TerminationVERTICAL, 90 Elbow to Horizontal OUT the Wall ModelExample a Venting Fireplace TOPTo Use the Vent Graph Figure Example BBelow Grade Installation Typical Basement InstallationPositioning the Fireplace Cutting the Hole FiguresExamples TOP Vent RUN Venting Examples When Using DVA47 Adaptor Vertically Off Top of Fireplace OnlyInstallation Instructions DVVK-4FV Direct Vent Termination KITInstallation Note Items Required For Installation Tools Building SuppliesInstallation of the Vertical Flex Termination Kit Before You StartStep-By-Step Installation For Flex DV Kit Roof Pitch DIA. Flex AIR Intake Pipe 35 ft. Max Quantity Number Item Description Repair Part No SuppliedDimensions in Feet Venting Fireplace RearExamples Rear Vent RUN DVVK-4RE Vent KIT Installation Instructions Installing Wall Thimble/Firestop AssemblyParts Verification DVVK-4RE Vent KIT Installation Instructions Sealing 4 102mm Diameter Flue Outlet TubeParts List Connecting to Rigid Vent SystemInstallation DVVK-4F Flex Vent Instructions TOP Vent onlyVertical Sidewall Installations Termination ClearancesInformation on Various Venting Routes and Components Vent Clearances Vent System Identification Special Venting Components Simpson DuraventInstalling Vent Components Figure DVVK-5RPInstalling Support Brackets Figure Venting Framing and FinishingSee Horizontal Termination Page 41 and Vertical Termination Installing Firestops Figures 64, 65, 66 ⅝ Venting Framing and Finishing⅝ Venting Framing and Finishing Horizontal Termination Installation DVVK-5F Flex Vent InstructionsVertical Termination General MaintenanceSee Figure Installing the Vent System in a Chase Determining Minimum Vent Height Above the RoofReassembly and Resealing Vent Pipe System Vertical TerminationLOG Placement 4 LOG SET Initial Lighting Operating InstructionsMillivolt System Pilot Flame FigureTRW Standing Pilot Wiring Diagram Lighting Instructions For Your SAFETY, Read Before LightingStanding Pilot Lighting Instructions To Turn OFF GAS to FireplacePilot and main burner extinguish while in operation Standing Pilot TroubleshootingFrequent pilot outage problem Glass sootsIntermittent Pilot Wiring Diagram Intermittent Pilot Operating InstructionsElectrical Connection Figure Intermittent Pilot Lighting Instructions To Turn OFF GAS to ApplianceDamage, personal injury or loss of life Checkout Intermittent Pilot TroubleshootingS8600H Intermittent Ignition Module Specifications OperationSafety Lockout Main Burner OperationIgnition System Checks Check ignition cable. Make sure ARC Length ActionIntermittent Pilot Troubleshooting Green LED Status Codes RF Standing Pilot Operating Instructions RF Transmitter Functions Status ActionWiring Diagram with Blower RF Wiring DiagramFor Your Safety Read Before Lighting RF Standing Pilot Lighting InstructionsWhat to do if YOU Smell GAS Maintenance and Service Parts View Parts List Index Part Number Description DVP42 DVP48Parts List FBB4 Optional Variable Speed Blower Installation Blower MotorBlower Wheels Volt AC Junction BOX Wiring Installation Instructions Optional Brick Liner Installation InstructionsAccessories FBB4Service Notes HOW to Order Repair Parts Service Notes

DVP42FP, P)-2 specifications

Empire Comfort Systems has established itself as a leader in the heating and venting industry, providing innovative solutions that cater to modern home heating needs. One of their standout products is the Empire Comfort Systems DVP42FP,P)-2, a direct vent gas fireplace that seamlessly combines aesthetics, efficiency, and technology.

At the heart of the DVP42FP,P)-2 is its contemporary design, which enhances the ambiance of any living space. With a sleek glass front and a range of stylish finishes, this fireplace serves as a perfect centerpiece, embodying both function and fashion. The generous viewing area allows for an unobstructed view of the mesmerizing flames, creating a cozy atmosphere in any room.

This fireplace is engineered for efficiency and performance. With an impressive heating output, the DVP42FP,P)-2 can effectively warm spaces while consuming minimal fuel. It boasts a high-efficiency rating, ensuring that homeowners can enjoy the warmth without incurring high energy costs. The direct vent technology allows for a sealed combustion system that draws air from outside while expelling exhaust gases directly outdoors. This ensures that the air quality inside the home is maintained while providing optimal heating performance.

Ease of use is another hallmark of the DVP42FP,P)-2. It features an intuitive remote control system, allowing users to adjust the temperature and flame settings conveniently from anywhere in the room. This level of user-friendly control enhances the overall experience, making it easy to create the perfect environment.

Another notable characteristic of this model is its safety features. Equipped with safety screens and an auto shut-off feature, the DVP42FP,P)-2 is designed to offer peace of mind, allowing families to enjoy their fireplace without worries about safety.

Maintenance is straightforward with the DVP42FP,P)-2, thanks to its accessible design. Regular upkeep is minimal, allowing homeowners to spend more time enjoying the warmth and beauty of their fireplace rather than worrying about system maintenance.

In conclusion, the Empire Comfort Systems DVP42FP,P)-2 is a captivating, efficient, and technologically advanced direct vent gas fireplace. With its modern design, high efficiency, user-friendly controls, and robust safety features, it represents a wise investment for anyone looking to enhance their home's comfort and aesthetic appeal. Whether for a new build or a renovation, this fireplace stands out as a premier choice for discerning homeowners.