Empire Comfort Systems P)-2, DVP42FP installation instructions DIA. Flex AIR Intake Pipe

Page 24

DVVK-4FV DIRECT VENT TERMINATION KIT (cont.)

17.To attach the vent connections at the fireplace, be sure the 7” diameter adapter collar has been installed per step 3. Apply a bead of silicone sealant to the 4” diameter flex connector, then slide the flex pipe adapter collar into the fireplace flue collar and secure by installing a minimum of two (2) screws through the flue collar and into the adapter. See Figure 36.

18.Apply sealant to the 7” diameter adapter collar, slide outer flex vent over the collar, then secure with a 7” diameter band clamp. See Figure 36.

19.Once the lower connections are made and the flex pipe is secured with support bands as required (3 feet minimum be- tween supports) then the roof flashing can be installed. See

Figure 37.

20.Install the roof flashing, and seal using common construc- tions practices.

21.An additional storm collar band is provided in kit that may be used as an attic insulation shield. The collar can be installed around the flex pipe (or hard pipe) just above the firestop thimble. This collar will act as a shield to prevent blown in- sulation from entering the thimble.

22.To complete the vent installation, install the vent termination cap to the top of the hard vent pipe assembly. Mate up the flue and outer telescopes with the hard pipe assembly, then secure by installing a minimum of two (2) sheet metal screws into the overlapped flanges of the cap and pipe.

23.Figure 38 shows a completed installation with components identified and other installation information such as heights and clearance to combustibles.

7” DIA. FLEX AIR INTAKE PIPE

4" DIA. FLEX FLUE PIPE

4" DIA. FLUE ADAPTER COLLAR

7" DIA. INLET ADAPTER COLLAR (WITH GASKET)

BAND CLAMP

APPLY HIGH TEMPERATURE SEALANT

Vent Cap

7"(178mm) Dia.

Storm

Hard Pipe

Collar

Must Extend

 

Through Roof

 

Flashing

 

Roof

Flashing

Roof

Exterior

Figure 36

Roof

Support

Assembly

7"(178mm) Dia.

Flex

1” (25mm)

Minimum

Clearance to

Combustibles

Figure 37

Page 24

21759-6-0608

Image 24
Contents Millivolt Standing Pilot Intermittent PilotRemote RF Models UL File NO. MH30033Table of Contents Important Safety Information LP-GAS Warning Odor No Odor Detected Odor FadeSome Points to Remember Requirements for Massachusetts Vent Directly BELOW. Keep Clear of ALL ObstructionsIntroduction Specifications Fireplace DimensionsRemote Control Options Description DVP42 DVP48Clearances Locating FireplaceClearances Figure Combustible MaterialInstalling a New Main Gas Cock GAS SupplyChecking Manifold Pressures Rear Vent Conversion Converting flue take-off to rear ventingInstallation Framing and FinishingVent Pipe Clearance Flush Mount Mantel Installation Figure Framing FigureFinishing Figures 12 Flush Wall Installation Combustible Surround InstallationVent Runs Figures 14, 15, 16, 17 VERTICAL, 90 Elbow with Horizontal TerminationVERTICAL, 90 Elbow to Horizontal OUT the Wall ModelVenting Fireplace TOP To Use the Vent Graph FigureExample a Example BBelow Grade Installation Typical Basement InstallationPositioning the Fireplace Cutting the Hole FiguresExamples TOP Vent RUN Venting Examples When Using DVA47 Adaptor Vertically Off Top of Fireplace OnlyInstallation Instructions DVVK-4FV Direct Vent Termination KITItems Required For Installation Tools Building Supplies Installation of the Vertical Flex Termination KitInstallation Note Before You StartStep-By-Step Installation For Flex DV Kit Roof Pitch DIA. Flex AIR Intake Pipe 35 ft. Max Quantity Number Item Description Repair Part No SuppliedDimensions in Feet Venting Fireplace RearExamples Rear Vent RUN DVVK-4RE Vent KIT Installation Instructions Installing Wall Thimble/Firestop AssemblyParts Verification DVVK-4RE Vent KIT Installation Instructions Sealing 4 102mm Diameter Flue Outlet TubeParts List Connecting to Rigid Vent SystemInstallation DVVK-4F Flex Vent Instructions TOP Vent onlyVertical Sidewall Installations Termination ClearancesInformation on Various Venting Routes and Components Vent Clearances Vent System Identification Special Venting Components Simpson DuraventInstalling Vent Components Figure DVVK-5RPInstalling Support Brackets Figure Venting Framing and FinishingSee Horizontal Termination Page 41 and Vertical Termination Installing Firestops Figures 64, 65, 66 ⅝ Venting Framing and Finishing⅝ Venting Framing and Finishing Horizontal Termination Installation DVVK-5F Flex Vent InstructionsGeneral Maintenance See Figure Installing the Vent System in a ChaseVertical Termination Determining Minimum Vent Height Above the RoofReassembly and Resealing Vent Pipe System Vertical TerminationLOG Placement 4 LOG SET Operating Instructions Millivolt SystemInitial Lighting Pilot Flame FigureTRW Standing Pilot Wiring Diagram For Your SAFETY, Read Before Lighting Standing Pilot Lighting InstructionsLighting Instructions To Turn OFF GAS to FireplaceStanding Pilot Troubleshooting Frequent pilot outage problemPilot and main burner extinguish while in operation Glass sootsIntermittent Pilot Wiring Diagram Intermittent Pilot Operating InstructionsElectrical Connection Figure Intermittent Pilot Lighting Instructions To Turn OFF GAS to ApplianceDamage, personal injury or loss of life Intermittent Pilot Troubleshooting S8600H Intermittent Ignition Module SpecificationsCheckout OperationSafety Lockout Main Burner OperationIgnition System Checks Check ignition cable. Make sure ARC Length ActionIntermittent Pilot Troubleshooting Green LED Status Codes RF Standing Pilot Operating Instructions RF Transmitter Functions Status ActionWiring Diagram with Blower RF Wiring DiagramFor Your Safety Read Before Lighting RF Standing Pilot Lighting InstructionsWhat to do if YOU Smell GAS Maintenance and Service Parts View Parts List Index Part Number Description DVP42 DVP48Parts List FBB4 Optional Variable Speed Blower Installation Blower MotorBlower Wheels Volt AC Junction BOX Wiring Installation Instructions Optional Brick Liner Installation InstructionsAccessories FBB4Service Notes HOW to Order Repair Parts Service Notes

DVP42FP, P)-2 specifications

Empire Comfort Systems has established itself as a leader in the heating and venting industry, providing innovative solutions that cater to modern home heating needs. One of their standout products is the Empire Comfort Systems DVP42FP,P)-2, a direct vent gas fireplace that seamlessly combines aesthetics, efficiency, and technology.

At the heart of the DVP42FP,P)-2 is its contemporary design, which enhances the ambiance of any living space. With a sleek glass front and a range of stylish finishes, this fireplace serves as a perfect centerpiece, embodying both function and fashion. The generous viewing area allows for an unobstructed view of the mesmerizing flames, creating a cozy atmosphere in any room.

This fireplace is engineered for efficiency and performance. With an impressive heating output, the DVP42FP,P)-2 can effectively warm spaces while consuming minimal fuel. It boasts a high-efficiency rating, ensuring that homeowners can enjoy the warmth without incurring high energy costs. The direct vent technology allows for a sealed combustion system that draws air from outside while expelling exhaust gases directly outdoors. This ensures that the air quality inside the home is maintained while providing optimal heating performance.

Ease of use is another hallmark of the DVP42FP,P)-2. It features an intuitive remote control system, allowing users to adjust the temperature and flame settings conveniently from anywhere in the room. This level of user-friendly control enhances the overall experience, making it easy to create the perfect environment.

Another notable characteristic of this model is its safety features. Equipped with safety screens and an auto shut-off feature, the DVP42FP,P)-2 is designed to offer peace of mind, allowing families to enjoy their fireplace without worries about safety.

Maintenance is straightforward with the DVP42FP,P)-2, thanks to its accessible design. Regular upkeep is minimal, allowing homeowners to spend more time enjoying the warmth and beauty of their fireplace rather than worrying about system maintenance.

In conclusion, the Empire Comfort Systems DVP42FP,P)-2 is a captivating, efficient, and technologically advanced direct vent gas fireplace. With its modern design, high efficiency, user-friendly controls, and robust safety features, it represents a wise investment for anyone looking to enhance their home's comfort and aesthetic appeal. Whether for a new build or a renovation, this fireplace stands out as a premier choice for discerning homeowners.