Empire Comfort Systems DVP42FP, P)-2 installation instructions Important Safety Information

Page 3

IMPORTANT SAFETY INFORMATION

Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly.

DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLED

If this appliance is installed directly on carpeting, tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.

The base referred to above does not mean the fireproof base as used on wood stoves. The protection is for rugs that are extremely thick and light colored tile.

Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.

Young children should be carefully supervised when they are in the same room as the appliance.

Clothing or other flammable material should not be placed on or near the appliance.

Adequate accessibility clearances for servicing and proper operation.

This appliance must not share or be connected to a flue serving a separate solid-fuel burning appliance.

Keep the area around your appliance clear of combustible materials, gasoline and other flammable vapor and liquids.

Under no circumstances should any solid fuels (wood, coal, paper or cardboard etc.) be used in this appliance.

The flow of combustion and ventilation air must not be obstructed in any way.

• Due to high temperatures the appliance should be located

• Do examine venting system periodically and replace damaged

out of traffic and away from furniture and draperies.

parts.

• The glass front or any part removed for servicing the appliance

• Do make a periodic visual check of pilot and burners. Clean

must be replaced prior to operating the appliance. Work

and replace damaged parts.

should be done by a qualified service person.

• CAUTION:The glass used in your fireplace is tempered glass.

• Keep burner and control compartment clean.

If the glass is cracked or damaged in any way, it should be

• Vent cap is hot while fireplace is in operation.

replaced only with a complete glass frame assembly from

Empire. See parts list on Pages 64 and 65 for ordering.

• Installation and repair should be done by a qualified service

• Do not use this fireplace if any part has been under water.

person. The appliance should be inspected before use

Immediately call a qualified service technician to inspect the

and at least annually by a qualified service person. More

heater and to replace any part of the control system and any

frequent cleaning may be required due to excessive lint from

gas control which has been under water.

carpeting, bedding materials, etc. It is imperative that control

 

compartments, burners and circulating air passageways of

• Any safety screen or guard removed for servicing an appliance

the appliance be kept clean.

must be replaced prior to operating the appliance.

• Do not put anything around the fireplace that will obstruct

 

the flow of ventilation air.

 

• Clearance in accordance with local installation codes and

 

the requirements of the gas supplier.

 

• Do keep the appliance area clear and free from combustible

 

material, gasoline and other flammable vapors and liquids.

 

 

 

21759-6-0608

Page 3

Image 3
Contents UL File NO. MH30033 Millivolt Standing PilotIntermittent Pilot Remote RF ModelsTable of Contents Important Safety Information LP-GAS Warning Odor No Odor Detected Odor FadeSome Points to Remember Vent Directly BELOW. Keep Clear of ALL Obstructions Requirements for MassachusettsIntroduction DVP42 DVP48 SpecificationsFireplace Dimensions Remote Control Options DescriptionCombustible Material ClearancesLocating Fireplace Clearances FigureInstalling a New Main Gas Cock GAS SupplyChecking Manifold Pressures Converting flue take-off to rear venting Rear Vent ConversionInstallation Framing and FinishingVent Pipe Clearance Flush Mount Mantel Installation Figure Framing FigureFinishing Figures 12 VERTICAL, 90 Elbow with Horizontal Termination Flush Wall InstallationCombustible Surround Installation Vent Runs Figures 14, 15, 16, 17Model VERTICAL, 90 Elbow to Horizontal OUT the WallExample B Venting Fireplace TOPTo Use the Vent Graph Figure Example aTypical Basement Installation Below Grade InstallationCutting the Hole Figures Positioning the FireplaceExamples TOP Vent RUN Vertically Off Top of Fireplace Only Venting Examples When Using DVA47 AdaptorDVVK-4FV Direct Vent Termination KIT Installation InstructionsBefore You Start Items Required For Installation Tools Building SuppliesInstallation of the Vertical Flex Termination Kit Installation NoteStep-By-Step Installation For Flex DV Kit Roof Pitch DIA. Flex AIR Intake Pipe 35 ft. Max Number Item Description Repair Part No Supplied QuantityVenting Fireplace Rear Dimensions in FeetExamples Rear Vent RUN DVVK-4RE Vent KIT Installation Instructions Installing Wall Thimble/Firestop AssemblyParts Verification Sealing 4 102mm Diameter Flue Outlet Tube DVVK-4RE Vent KIT Installation InstructionsConnecting to Rigid Vent System Parts ListDVVK-4F Flex Vent Instructions TOP Vent only InstallationVertical Sidewall Installations Termination ClearancesInformation on Various Venting Routes and Components Vent Clearances Special Venting Components Simpson Duravent Vent System IdentificationDVVK-5RP Installing Vent Components FigureVenting Framing and Finishing Installing Support Brackets FigureSee Horizontal Termination Page 41 and Vertical Termination ⅝ Venting Framing and Finishing Installing Firestops Figures 64, 65, 66⅝ Venting Framing and Finishing Horizontal Termination DVVK-5F Flex Vent Instructions InstallationDetermining Minimum Vent Height Above the Roof General MaintenanceSee Figure Installing the Vent System in a Chase Vertical TerminationVertical Termination Reassembly and Resealing Vent Pipe SystemLOG Placement 4 LOG SET Pilot Flame Figure Operating InstructionsMillivolt System Initial LightingTRW Standing Pilot Wiring Diagram To Turn OFF GAS to Fireplace For Your SAFETY, Read Before LightingStanding Pilot Lighting Instructions Lighting InstructionsGlass soots Standing Pilot TroubleshootingFrequent pilot outage problem Pilot and main burner extinguish while in operationIntermittent Pilot Wiring Diagram Intermittent Pilot Operating InstructionsElectrical Connection Figure Intermittent Pilot Lighting Instructions To Turn OFF GAS to ApplianceDamage, personal injury or loss of life Operation Intermittent Pilot TroubleshootingS8600H Intermittent Ignition Module Specifications CheckoutMain Burner Operation Safety LockoutARC Length Action Ignition System Checks Check ignition cable. Make sureIntermittent Pilot Troubleshooting Green LED Status Codes RF Standing Pilot Operating Instructions Status Action RF Transmitter FunctionsRF Wiring Diagram Wiring Diagram with BlowerFor Your Safety Read Before Lighting RF Standing Pilot Lighting InstructionsWhat to do if YOU Smell GAS Maintenance and Service Parts View Index Part Number Description DVP42 DVP48 Parts ListParts List FBB4 Optional Variable Speed Blower Installation Blower MotorBlower Wheels Volt AC Optional Brick Liner Installation Instructions Junction BOX Wiring Installation InstructionsFBB4 AccessoriesService Notes HOW to Order Repair Parts Service Notes

DVP42FP, P)-2 specifications

Empire Comfort Systems has established itself as a leader in the heating and venting industry, providing innovative solutions that cater to modern home heating needs. One of their standout products is the Empire Comfort Systems DVP42FP,P)-2, a direct vent gas fireplace that seamlessly combines aesthetics, efficiency, and technology.

At the heart of the DVP42FP,P)-2 is its contemporary design, which enhances the ambiance of any living space. With a sleek glass front and a range of stylish finishes, this fireplace serves as a perfect centerpiece, embodying both function and fashion. The generous viewing area allows for an unobstructed view of the mesmerizing flames, creating a cozy atmosphere in any room.

This fireplace is engineered for efficiency and performance. With an impressive heating output, the DVP42FP,P)-2 can effectively warm spaces while consuming minimal fuel. It boasts a high-efficiency rating, ensuring that homeowners can enjoy the warmth without incurring high energy costs. The direct vent technology allows for a sealed combustion system that draws air from outside while expelling exhaust gases directly outdoors. This ensures that the air quality inside the home is maintained while providing optimal heating performance.

Ease of use is another hallmark of the DVP42FP,P)-2. It features an intuitive remote control system, allowing users to adjust the temperature and flame settings conveniently from anywhere in the room. This level of user-friendly control enhances the overall experience, making it easy to create the perfect environment.

Another notable characteristic of this model is its safety features. Equipped with safety screens and an auto shut-off feature, the DVP42FP,P)-2 is designed to offer peace of mind, allowing families to enjoy their fireplace without worries about safety.

Maintenance is straightforward with the DVP42FP,P)-2, thanks to its accessible design. Regular upkeep is minimal, allowing homeowners to spend more time enjoying the warmth and beauty of their fireplace rather than worrying about system maintenance.

In conclusion, the Empire Comfort Systems DVP42FP,P)-2 is a captivating, efficient, and technologically advanced direct vent gas fireplace. With its modern design, high efficiency, user-friendly controls, and robust safety features, it represents a wise investment for anyone looking to enhance their home's comfort and aesthetic appeal. Whether for a new build or a renovation, this fireplace stands out as a premier choice for discerning homeowners.