Empire Comfort Systems CIVF-25-21 Lighting Instructions, For Your Safety Read Before Lighting

Page 15

LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION

MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance

Do not touch any electrical switch; do not use any phone in your building

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you can not reach your gas supplier, call the fire de- partment.

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service tech- nician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat to lowest setting.

3.Turn off all electric power to the appli- ance (if applicable).

4.Lower valve cover.

5.Push in gas control knob slight-

ly and turn clockwiseto "OFF." NOTE: Knob cannot

be turn from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force.

6.Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low "B" in the safety information above on this plate. If you do not smell gas,

go to the next step.

7.Find pilot - The pilot is attached to the main burner behind the front log.

8.Turn gas control knob counterclockwise to "PILOT."

9.Push in control knob all the way and hold in. Repeatedly push the Piezo Ignitor Button until the pilot is lit. Continue

to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 9.

If knob does not pop up when released, stop and immedi- ately call a qualified service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.

10.Attention! Gas control has an INTERLOCK latch- ing device. When the pilot is initially lit and the safety magnet is energized (pilot stays "on"), the INTERLOCK latching device becomes operative. If the gas control is turned to "OFF" position or gas flow to the appliance shut off, the pilot cannot be relighted until the safety magnet is de-energized (approximately 60 seconds). There will be an audible "click" when the safety magnet in the gas control is de-energized. Pilot can now be relighted. Repeat steps 5 thru 9.

11.Turn gas control knob counterclockwise

to "ON."

12.Raise valve cover.

13.Turn on all electric power to the appliance (if ap- plicable).

14.Set thermostat to desired setting.

TO TURN OFF GAS APPLIANCE

1.Set the thermostat to lowest setting.

2.Turn off all electric power to the appliance if service is to be performed (if applicable).

3.Lower valve cover.

4.Push in gas control knob slightly and turn clockwise to "OFF."

5.Raise valve cover.

16938-3-0806

Page 15

Image 15
Contents Installation Instructions Table of Contents Minimize this effect. The use of this fan will also improve Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction SpecificationsInstructions to Installer Qualified Installing AgencyUnusually tight construction is defined as construction where Unusually Tight ConstructionChecking Manifold Pressure Installing a New Main Gas CockPressure Testing of the Gas Supply System Recommended Gas Pipe DiameterInstallation on Rugs and Tile ClearancesClearances Figures 2, 3 Appliance Hardware Package Appliance Hardware Package Parts ListDetailed Instructions Follow Assembly of Stove Casting16938-3-0806 Assembly of Stove Casting Parts List Optional Stone Inlay InstallationWire Channel Installation Installation of Optional Stone InlayStanding Pilot Operation LOG PlacementOperating Guidelines Initial Lighting FigureLighting Instructions For Your Safety Read Before LightingCorrect Pilot Flame Pattern Incorrect Pilot Flame Pattern Pilot Flame CharacteristicsCleaning the Log Set and Firebox Main Burner Flame CharacteristicsWiring Wiring Diagram Figure MaintenanceTroubleshooting Delayed ignition of main burnerMain burner does not light after ODS/pilot is lit HOW to Order Repair Parts Parts List for CIVF-25-21 Parts List for Stove CastingParts View for Stove Casting Parts View for CIVF-25-21 Optional Blower Installation Instructions Installing Optional CIB-2 BlowerFan Control Index Part Description CleaningWiring Blower MotorService Notes