Empire Comfort Systems CIVF-25-21 Clearances Figures 2, 3, Installation on Rugs and Tile

Page 8

CLEARANCES

Clearances (Figures 2, 3 and 4)

When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.

Top of appliance (ceiling)

24

inches

Rear Wall

2

inches

Side Wall

6

inches

Heater Corners (45° angle) to Wall

4

inches

Floor

0

inches

Provide adequate clearances around air openings.

Adequate accessibility clearances for purposes of servicing and proper operation must be provided.

Installation on Rugs and Tile

If this appliance is to be installed directly on carpeting, tile, or other combustible material, other than wood flooring, the appli- ance shall be installed on a metal or wood panel extending the full width and depth of the appliance.

The base referred to above does not mean the fire-proof base as used on wood stoves. The protection is primarily for rugs that may be extremely thick and light-color tile that can discolor.

Figure 3

Figure 2

Figure 4

Page 8

16938-3-0806

Image 8
Contents Installation Instructions Table of Contents Important Safety Information Minimize this effect. The use of this fan will also improveSafety Information for Users of LP-GAS LP-GAS Warning OdorSpecifications Instructions to InstallerQualified Installing Agency IntroductionUnusually Tight Construction Unusually tight construction is defined as construction whereInstalling a New Main Gas Cock Pressure Testing of the Gas Supply SystemRecommended Gas Pipe Diameter Checking Manifold PressureClearances Figures 2, 3 Installation on Rugs and TileClearances Appliance Hardware Package Parts List Appliance Hardware PackageAssembly of Stove Casting Detailed Instructions Follow16938-3-0806 Assembly of Stove Casting Optional Stone Inlay Installation Wire Channel InstallationInstallation of Optional Stone Inlay Parts ListLOG Placement Operating GuidelinesInitial Lighting Figure Standing Pilot OperationFor Your Safety Read Before Lighting Lighting InstructionsPilot Flame Characteristics Correct Pilot Flame Pattern Incorrect Pilot Flame PatternMain Burner Flame Characteristics Cleaning the Log Set and FireboxWiring Maintenance Wiring Diagram FigureMain burner does not light after ODS/pilot is lit TroubleshootingDelayed ignition of main burner HOW to Order Repair Parts Parts List for Stove Casting Parts List for CIVF-25-21Parts View for Stove Casting Parts View for CIVF-25-21 Fan Control Optional Blower Installation InstructionsInstalling Optional CIB-2 Blower Cleaning WiringBlower Motor Index Part DescriptionService Notes