Empire Comfort Systems CIVF-25-21 Optional Stone Inlay Installation, Wire Channel Installation

Page 13

OPTIONAL STONE INLAY INSTALLATION

Whenever the standard grill top is replaced with a stone inlay you must install the top shield and heat shield, which are provided with the stone inlay.

Installation of Optional Stone Inlay

1.Remove left grill, center grill and right grill from casting top.

2.Remove casting top from outer casting.

3.Place the casting top on a non-abrasive surface in order to protect the porcelain finish. The exterior of the casting top should be facing the non-abrasive surface.

4.Attach 11 5/8" x 11 5/8" top shield to the interior of the casting top with (1) 3/8" bolt provided in hardware package.

5.Locate the (4) screw holes on the heat exchanger top. The screw holes are 8 3/4" apart. Position the angled front edge on the 12" x 19 3/8" heat shield with the front of the firebox. Align the (4) tabs with clearance holes on the 12" x 19 3/8" heat shield with the (4) screw holes on the heat exchanger top. Attach the 12" x 19 3/8" heat shield to the heat exchanger top with (4) 1/2" hex-head screws provided in hardware package.

6.Place the casting top onto the casting. The casting top nests into the casting.

7.Insert center stone inlay, left stone inlay and right stone inlay into casting top.

8.Installation of stone inlay is completed.

Parts List

Part Description

Part

Quantity

 

Number

Supplied

11 5/8" x 11 5/8" Top Shield

CI-091

1

12" x 19 3/8" Heat Shield

CI-092

1

3/8" Bolt

R-3646

1

1/2" Hex-Head Screw

R-2737

4

WIRE CHANNEL INSTALLATION

The ON/OFF/REMOTE switch with harness is factory installed into the switch box. After the firebox is installed into the casting the wire channel can be installed.

1.Attach switch box on the left side of rear cover with (2) 10 x 1/2" screws.

2.Route wires from ON/OFF/REMOTE switch within wire channel.

3.Attach wire channel on the left side of the rear cover with (4) 10 x 1/2" screws.

4.Attach the black and green (wires) female

push-ons to the TH/TPand TH (two outside male tabs) terminals on gas valve.

Figure 12

16938-3-0806

Page 13

Image 13
Contents Installation Instructions Table of Contents Minimize this effect. The use of this fan will also improve Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASInstructions to Installer SpecificationsQualified Installing Agency IntroductionUnusually tight construction is defined as construction where Unusually Tight ConstructionPressure Testing of the Gas Supply System Installing a New Main Gas CockRecommended Gas Pipe Diameter Checking Manifold PressureClearances Installation on Rugs and TileClearances Figures 2, 3 Appliance Hardware Package Appliance Hardware Package Parts ListDetailed Instructions Follow Assembly of Stove Casting16938-3-0806 Assembly of Stove Casting Wire Channel Installation Optional Stone Inlay InstallationInstallation of Optional Stone Inlay Parts ListOperating Guidelines LOG PlacementInitial Lighting Figure Standing Pilot OperationLighting Instructions For Your Safety Read Before LightingCorrect Pilot Flame Pattern Incorrect Pilot Flame Pattern Pilot Flame CharacteristicsCleaning the Log Set and Firebox Main Burner Flame CharacteristicsWiring Wiring Diagram Figure MaintenanceDelayed ignition of main burner TroubleshootingMain burner does not light after ODS/pilot is lit HOW to Order Repair Parts Parts List for CIVF-25-21 Parts List for Stove CastingParts View for Stove Casting Parts View for CIVF-25-21 Installing Optional CIB-2 Blower Optional Blower Installation InstructionsFan Control Wiring CleaningBlower Motor Index Part DescriptionService Notes