Lennox International Inc Elite Series Gas Furnace Upflow/Horizontal Air Discharge, EL280UH Feet

Page 19

TABLE 4

Capacity of Type B Double−Wall Vents with Single−Wall Metal Connectors

Serving a Single Category I Appliance

 

 

 

 

 

Vent and Connector Diameter − D (inches)

 

 

 

Height

Lateral

 

 

 

 

 

 

 

 

 

 

 

 

 

3 Inch

 

4 Inch

 

5 Inch

 

6 Inch

H

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Appliance Input Rating in Thousands of Btu Per Hour

 

 

 

(feet)

(feet)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MIN

 

MAX

MIN

 

MAX

MIN

 

MAX

MIN

 

MAX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

38

 

77

59

 

151

85

 

249

126

 

373

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

39

 

51

60

 

96

85

 

156

123

 

231

6

 

 

 

 

 

 

 

 

 

 

 

 

 

4

NA

 

NA

74

 

92

102

 

152

146

 

225

 

 

 

 

 

 

6

NA

 

NA

83

 

89

114

 

147

163

 

220

 

0

37

 

83

58

 

164

83

 

273

123

 

412

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

39

 

56

59

 

108

83

 

176

121

 

261

8

 

 

 

 

 

 

 

 

 

 

 

 

 

5

NA

 

NA

77

 

102

107

 

168

151

 

252

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

NA

 

NA

90

 

95

122

 

161

175

 

243

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

37

 

87

57

 

174

82

 

293

120

 

444

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

39

 

61

59

 

117

82

 

193

119

 

287

10

 

 

 

 

 

 

 

 

 

 

 

 

 

5

52

 

56

76

 

111

105

 

185

148

 

277

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

NA

 

NA

97

 

100

132

 

171

188

 

261

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

36

 

93

56

 

190

80

 

325

116

 

499

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

38

 

69

57

 

136

80

 

225

115

 

337

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

5

51

 

63

75

 

128

102

 

216

144

 

326

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

NA

 

NA

95

 

116

128

 

201

182

 

308

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

NA

 

NA

NA

 

NA

158

 

186

220

 

290

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

35

 

96

54

 

200

78

 

346

114

 

537

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

37

 

74

56

 

148

78

 

248

113

 

375

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

50

 

68

73

 

140

100

 

239

141

 

363

20

 

 

 

 

 

 

 

 

 

 

 

 

 

10

NA

 

NA

93

 

129

125

 

223

177

 

344

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

NA

 

NA

NA

 

NA

155

 

208

216

 

325

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

NA

 

NA

NA

 

NA

186

 

192

254

 

306

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

34

 

99

53

 

211

76

 

372

110

 

584

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

37

 

80

55

 

164

76

 

281

109

 

429

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

49

 

74

72

 

157

98

 

271

136

 

417

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

10

NA

 

NA

91

 

144

122

 

255

171

 

397

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

NA

 

NA

115

 

131

151

 

239

208

 

377

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

NA

 

NA

NA

 

NA

181

 

223

246

 

357

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

NA

 

NA

NA

 

NA

NA

 

NA

NA

 

NA

NOTE − Single appliance venting configurations with zero lateral lengths are assumed to have no elbows in the vent system. For all other vent configurations, the vent system is assumed to have two 90° elbows. For each additional 90° elbow or equivalent (for example two 45° elbows equal one 90° elbow) beyond two, the maximum capacity listed in the venting table should be reduced by 10 percent (0.90 x maxi- mum listed capacity).

Page 19

Image 19
Contents Table of Contents Installation Instructions EL280UHSupply AIR Opening Unit Dimensions − inches mmParts Arrangement EL280UH Gas Furnace Safety InformationShipping and Packing List General Use of Furnace as Construction HeaterCombustion, Dilution & Ventilation Air Equipment in Confined Space ALL AIR from Inside Equipment in Confined Space Setting Equipment Return Air Bracket Duct System FiltersUpflow Position VentingHorizontal Right Position Horizontal Left PositionVent Connection Upflow and Horizontal Position Common Venting Using Metal−Lined Masonry Chimney −1/2 To these instructions and the provided venting tables. If Feet FAN + FAN FAN + NAT 130 Carbon Monoxide Poisoning Hazard Leum gases Gas PipingHorizontal Applications Possible Gas Piping Configurations Electrical Interior MAKE−UP BOX InstallationElectrostatic Discharge ESD Page Field Wiring Applications OFF EL280UH Schematic Wiring Diagram TWO−STAGE Integrated Control Typical EL280UH Field Wiring DiagramIntegrated Control Unit Start−Up For Your Safety Read Before LightingProper Combustion Gas Pressure AdjustmentHigh Altitude Manifold Pressure Settings at all Altitudes Heat FAN-OFF Time in Seconds Other Unit AdjustmentsHeating Sequence of Operation Blower Data Pressure Bottom and One Side Electrical SHOCK, Fire Or Explosion Hazard ServiceHeat Exchanger Removal EL280UH BURNER, Combustion AIR Inducer AssemblyPage Repair Parts List Planned ServiceFlash Code Status / Error Description Integrated Control Diagnostic CodesLED On Next Troubleshooting Heating Sequence of OperationHeating Sequence of Operation U1.40 microamps Or Heat Demand is SATISFIED. a Five Cooling Sequence of Operation Troubleshooting Cooling Sequence of OperationContinuous LOW Speed FAN Sequence of Operation Troubleshooting Continuous Fan Sequence of OperationStart−Up & Performance Check List Drain Line Cooling ModeTemperature Rise Unit Operation
Related manuals
Manual 7 pages 50.25 Kb

Elite Series Gas Furnace Upflow/Horizontal Air Discharge, EL280UH specifications

Lennox International Inc. has established itself as a leader in the heating and cooling industry, providing innovative solutions for both residential and commercial environments. One of their notable products is the EL280UH, a high-efficiency gas furnace designed to offer optimal comfort while minimizing energy consumption.

The EL280UH operates with an impressive Annual Fuel Utilization Efficiency (AFUE) rating of up to 80%. This efficiency rating means that 80% of the fuel consumed is converted into heat, making it a cost-effective option for homeowners looking to reduce their utility bills. The furnace’s design is tailored to deliver reliable warmth during the coldest months, ensuring a comfortable home environment.

A key feature of the EL280UH is its two-stage heating capability. This technology allows the furnace to operate at a lower heating output for less demanding conditions, which not only conserves energy but also helps maintain a more consistent temperature in the home. When the demand for heat increases, the furnace can seamlessly transition to its higher output setting, providing quick and effective heating when needed.

Additionally, the EL280UH is equipped with a durable cabinet that minimizes heat loss, enhancing overall performance. The design incorporates several sound-dampening features as well, which contributes to quieter operation, allowing homeowners to enjoy a serene indoor environment.

The furnace also includes an advanced control system that integrates easily with smart home technology. This feature enables users to monitor and adjust their heating settings from anywhere using a smartphone app, creating added convenience and control over home heating.

Safety is another paramount aspect of the EL280UH. It includes an integrated flame sensor and pressure switch, ensuring reliable operation while minimizing risks associated with furnace malfunctions. The design adheres to stringent safety standards, providing users with peace of mind.

In summary, the Lennox EL280UH furnace stands out for its high efficiency, advanced features, and commitment to user safety. Its two-stage heating capability, quiet operation, and smart home integration make it an excellent choice for homeowners looking to enhance their heating system while being energy-conscious. The EL280UH embodies Lennox's dedication to quality and innovation, ensuring that comfort and efficiency go hand in hand.