Johnson Controls TM9X*MP installation manual Horizontal Left, Configuration

Page 19

Johnson Controls Unitary

FIGURE 24: Horizontal Left

When drain hose routing changes are required, be sure to cap all un-used openings.

If rerouting hoses - excess length should be cut off so that no sagging loops will collect and hold condensate, which will cause the furnace to not operate.

Products

Configuration

HORIZONTAL - LEFT

INDUCER ROTATED

AIRFLOW

2

Move pressure switch hose

 

to this position.

 

NOTE: May require the longer

 

hose that is provided with

 

wider cabinets

 

 

1 Move rain gutter

 

 

 

hose to this position

2 Move pressure switch

AIRFLOW

 

hose to this position.

 

NOTE: May require

 

 

 

 

the longer hose that

 

 

is provided with

 

 

wider cabinets

1

Move rain gutter hose to this position

NOTE: May require hose extension that is provided with wider cabinets

3

Move

4 Change condensate

 

 

 

drain connection to

 

 

 

condensate

 

 

the 90° fitting provided

 

 

 

 

drain hose to

 

 

 

 

this position

 

 

 

HORIZONTAL - LEFT

INDUCER AS RECEIVED

697936

19

3

 

 

 

5 Change condensate drain

Move rain gutter hose to this position

4

 

 

connection to the 90° fitting provided

NOTE: May require hose extension

 

 

 

 

 

 

Move condensate

 

 

 

that is provided with wider cabinets

 

 

 

 

drain hose to this position

 

 

 

 

 

 

-UIM-B-01211

Image 19
Contents Combustion AIR and Vent System List of SectionsList of Figures List of TablesSpecific Safety Rules and Precautions Section I SafetySafety Requirements Codes and Standards Combustion AIR Quality List of ContaminantsFurnace Location and Clearances InspectionDuct Flanges Floor Base and Ductwork Installation DownflowSection II Ductwork Ductwork General InformationCoil Flange Installation Coil InstallationCOIL/FURNACE Assembly MC/FC/PC Series Coils Furnace Assembly MC & FC Series CoilsCritical Coil Projection Coil / Furnace Assembly HC Series CoilsDownflow Duct Connectors Bottom Return and Attic InstallationsDownflow Application Horizontal ApplicationBtuh kW Filter InstallationCabinet Dimensions Inches Section III FiltersSide Return GAS SafetyGAS Piping Installation Section IV GAS PipingManifold Pressures in. w.c High Altitude Pressure Switch ConversionGAS Orifice Conversion for Propane LP High Altitude GAS Orifice ConversionSupply Voltage Connections Section V Electrical PowerElectrical Power Connections LOW Voltage Control Wiring ConnectionsSingle Stage Air Conditioner Single Stage Furnace Single Stage Heat Pump Single Stage Furnace Twinning Accessory ConnectionsElectronic AIR Cleaner Connection Humidifier ConnectionCondensate Drain Termination Will cause the furnace Johnson Controls Downflow ConfigurationHorizontal Left ConfigurationHorizontal Right Inducer Rotated Model Input Pipe Size Maximum Combustion AIR and Vent SafetySection VII Combustion AIR and Vent System Combustion AIR/VENT Pipe SizingFitting Equivalent Length Combustion AIR and Vent Piping AssemblyElbow a Dimension Combustion AIR / VentingHome Layout Vent ClearancesVent Applications and Termination Vent SystemVenting Multiple Units Ambient Combustion Air Supply Downward VentingOutdoor Combustion Air Combustion AIR SupplyDampers, Louvers and Grilles Canada Only Combustion Air Source From OutdoorsFree Area Ventilated Combustion Air Air Supply Openings and DuctsVentilated Combustion Air Termination Specially Engineered Installations Section Viii START-UP AdjustmentsVent Blower Rotation Ignition System Sequence GAS Piping Leak CheckCalculating the Furnace Input NAT. GAS Seconds For Revolution Cu FtRevolution Read the inlet gas pressure Adjustment of Manifold GAS Pressure & Input RateRead the manifold gas pressure Adjustment of FAN Control Settings Adjustment of Temperature RiseControl Circuit Fuse Section IX Safety ControlsBlower Door Safety Switch Rollout Switch ControlsSection X Normal Operation and Diagnostics Diagnostic Fault Code Storage and Retrieval Replacement Part Contact Information Section XI Replacement Parts ListFabricated Parts Section XII Wiring Diagram Wiring FurnaceJohnson Controls Unitary Products York Drive Norman, OK

TM9X*MP specifications

The Johnson Controls TM9X*MP series represents a significant advancement in the realm of HVAC control systems, positioning itself as a versatile solution for both commercial and residential applications. Renowned for its intelligent design and user-friendly interface, the TM9X*MP series aims to enhance energy efficiency and provide comfort to its users.

One of the standout features of the TM9X*MP series is its advanced communication capabilities. It employs the latest communication protocols, including BACnet and Modbus, which facilitate seamless integration with various building management systems. This connectivity ensures that users can monitor and control their HVAC systems remotely, providing unparalleled convenience and control over their environment.

Further enhancing its adaptability, the TM9X*MP series supports a wide range of HVAC equipment, including heat pumps, rooftop units, and variable air volume systems. This flexibility makes it an ideal choice for diverse applications, catering to the specific needs of different building types and operational requirements.

Energy efficiency is a significant focus of the TM9X*MP series. The system is equipped with advanced algorithms that optimize HVAC performance based on real-time data inputs. By utilizing trends in occupancy and weather forecasts, the TM9X*MP can make informed adjustments to operation schedules and settings, ensuring minimal energy wastage while maintaining optimal comfort levels.

Another notable characteristic of the TM9X*MP series is its intuitive touchscreen interface. This user-centric design makes it easy for operators to navigate through various settings and configurations, reducing the complexity often associated with HVAC controls. The interface can display vital system information, including energy consumption metrics and system diagnostics, empowering users to make informed decisions regarding their HVAC systems.

The TM9X*MP series also prioritizes robustness and reliability. Built with high-quality components, these controllers are designed to withstand varying environmental conditions, ensuring extensive operational longevity. Furthermore, the comprehensive support and resources provided by Johnson Controls augment the TM9X*MP series’ reputation for exceptional service and performance.

In conclusion, the Johnson Controls TM9X*MP series is a versatile and reliable solution for modern HVAC control needs. Its advanced communication capabilities, energy-efficient algorithms, user-friendly interface, and robust design make it a strong contender in the market, catering to the dynamic demands of contemporary heating and cooling applications. Whether for large commercial buildings or smaller residential units, the TM9X*MP series stands out as a top-tier choice for HVAC management.