Williams 1773512, 1773511 What To Do If The Red Lamp Is Lit, How To Shut Off The Appliance

Page 14
WHAT TO DO IF THE RED LAMP IS LIT

WHAT TO DO IF THE RED LAMP IS LIT

This appliance has an electronic flame supervision device. If the flame disappears the gas flow will be automatically shut off and the red lamp will light instead of the green one. The appliance will attempt to relight if you do ONE of the following:

A.Turn off the electric supply to the appliance for approximately 40 seconds and turn it on again; OR

B.Turn the thermostat knob to the zero setting, then turn it back to a comfortable setting after approximately 40 seconds; OR

C.Press the SUMMER/WINTER button to the SUMMER position (button down) for approximately 40 seconds and set it back (button up) to the WINTER position.

HOW TO SHUT OFF THE APPLIANCE

1.Turn the thermostat knob to the ZERO position.

2.Turn the I-O switch on the programmable clock to the ZERO position.

3.Turn off all electric supply to the appliance.

4.Turn the gas shutoff valve installed on the gas supply line upstream to the unit to the CLOSED position.

USING THE FEATURES OF YOUR FURNACE

GREEN LAMP: It is lit when the flame is ON.

RED LAMP: In case the flame disappears, the gas flow will be shut off and the red lamp will be lit. The furnace is locked-out. To reset the furnace, follow the instructions above, "WHAT TO DO IF THE RED LAMP IS LIT."

MANUAL/PROGRAM BUTTON: When the button is down, the furnace keeps the temperature set by the thermostat according to the clock's program. When the button is up, the furnace thermostat maintains the temperature.

THERMOSTAT: Turn clockwise to increase the temperature, turn counterclockwise to decrease it.

SUMMER/WINTER: When the button is up, the furnace will operate in heating mode according to the thermostat and/or clock's program. When the button is down, the appliance will provide ventilation.

MIN/MAX BUTTON: For faster heating, keep this button up. For soft heating and silent operation, keep this button down.

HUMIDIFIER: water filling hole

HUMIDIFIER: For better comfort this furnace is equipped with a humidifier. It is very easy to use. Using a funnel, periodically add water to the small tank located on the top left side of the furnace. Normally, the tank needs to be refilled after 4 - 5 days.

NOTE: The use of water low in limestone or distilled is advisable in order to prevent any possible calcareous sedimentation that may be difficult to remove.

Anticalcareous tablets for humidifiers are commercially available. The humidifier capacity is 11.8 fluid ounces (0.35 liters).

13

Image 14
Contents Williams Furnace Co., 250 West Laurel Street, Colton, CA 92324 U.S.A Direct-Vent Wall FurnaceTable of Contents General Information and Technical Data Instructions to InstallerLP Gas Warning Odor Safety Rules and General WarningsSafety Information for Users of LP Gas That’s your signal to go into immediate actionTechnical Data Some Points to RememberInstallation Wall InstallationFlue outlet tube length = wall thickness + 1-5/16-inches 7.9 mm Outside Location for Vent TerminalAir inlet tube length = wall thickness + 3/32-inches 2.4 mm A + 33.3 mm 13. Relocate the vent cap and attach it with the screws. Figure Nozzle Part Number Gas ConversionsGas Type Nozzle DiameterPressure Testing of the Gas Supply System High Altitude AdjustmentInstalling a New Main Gas Shutoff Valve Gas SupplyChecking the Gas Manifold Pressure First Firing the FurnaceChecking the Gas Inlet Pressure A B CElectrical Wiring Diagram Key OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATINGOperating Instructions TO TURN OFF GAS TO APPLIANCEWHAT TO DO IF THE RED LAMP IS LIT HOW TO SHUT OFF THE APPLIANCEUSING THE FEATURES OF YOUR FURNACE Checking, Removing and Reassembling of the Vent Air Intake System Checking and Adjusting the Gas Manifold PressureServicing Lubrication of Moving PartsAnnual Maintenance Requirements Programmable Timer OverviewProgramming the Timer Setting and Adjustment Initial ConditionsDay and Time Setting Manual OperationUsing the Skip Function Cancelling a Single ProgramCancelling of all Preset Programs Skip Function Procedure During OperationStep Troubleshooting Starting Sequence ElectricalTroubleshooting Step Summer Mode StepTroubleshooting Step Starting Sequence Gas Electric Box Replacement PartsGas Assembly M2 - Fan Thermostat Fan Blades 4 pieces M - Fan Motor 2 Pieces RP8 Flame Sensor RP7 Spark Igniter 2 piecesS - Combustion Blower Motor M1 - Overheat Thermostat Part NumberJLTT015 Part Number JLTT023 Part Number JMTR017