Bryant 312AAV/JAV instruction manual Accessory List, Description Part Number

Page 55

Table 18 – Accessory List

DESCRIPTION

PART NUMBER

NOTES

 

 

 

 

FILCABXX0016

Filter cabinet 16” (406 mm) for 4” (102 mm) wide filter

 

 

 

Media Filter Cabinet

FILCABXX0020

Filter cabinet 20” (508 mm) for 4” (102 mm) wide filter

 

 

 

 

FILCABXX0024

Filter cabinet 24” (610 mm) for 4” (102 mm) wide filter

 

 

 

 

FILXXCAR0016

Filter Cartridge replacements for FILCAB media cabinet

 

 

 

Cartridge Media Filter

FILXXCAR0020

Filter Cartridge replacements for FILCAB media cabinet

 

 

 

 

FILXXCAR0024

Filter Cartridge replacements for FILCAB media cabinet

 

 

 

 

EXPXXUNV0016

16” (406 mm) Replacement Expandable Filter assembly

 

 

 

EZ Flex Media Filter with End Caps

EXPXXUNV0020

20” (508 mm) Replacement Expandable Filter assembly

 

 

 

 

EXPXXUNV0024

24” (610 mm) Replacement Expandable Filter assembly

 

 

 

 

EXPXXFIL0016

16” (406 mm) Replacement filter for EXPUNV assembly

 

 

 

Replacement EZ Flex Filter Media

EXPXXFIL0020

20” (508 mm) Replacement filter for EXPUNV assembly

 

 

 

 

EXPXXFIL0024

24” (610 mm) Replacement filter for EXPUNV assembly

 

 

 

 

KGAFR0401B14

Bottom return filter rack 14” (356 mm) casing

 

 

 

External Bottom Return Filter Rack

KGAFR0501B17

Bottom return filter rack 17” (432 mm) casing

 

 

KGAFR0601B21

Bottom return filter rack 21” (533 mm) casing

 

 

 

 

 

KGAFR0701B24

Bottom return filter rack 24” (610 mm) casing

 

 

 

External Side Return Filter Rack

KGAFR0801SRE

Ext. Side filter rack--- all casings--- includes filter

 

 

 

 

KGAWF1301UFR†

(1) unframed filter 16x25x3/4 (406x635x19 mm)

 

 

 

 

KGAWF1401UFR

(1) unframed filter 20x25x3/4 (508x635x19 mm)

 

 

 

Unframed Filter 3/4--- in. (19 mm)

KGAWF1501UFR

(1) unframed filter 24x25x3/4 (610x635x19 mm)

 

 

KGAWF1306UFR†

(6) unframed filter 16x25x3/4 (406x635x19 mm)

 

 

 

 

 

KGAWF1406UFR

(6) unframed filter 20x25x3/4 (508x635x19 mm)

 

 

 

 

KGAWF1506UFR

(6) unframed filter 24x25x3/4 (610x635x19 mm)

 

 

 

Flue Extension

KGAFE0112UPH

(12) vent extension 4” (102 mm) dia. x 3--- 1/2” (89 mm)

 

 

 

*Twinning Kit

KGATW0601HSI

Single or two stage PSC equipped units only

 

 

 

Combustible Floor Base

KGASB0201ALL

Adjustable floor base --- fits all casing sizes

 

 

 

Downflow Vent Guard

KGBVG0101DFG

Vent flue shield --- downflow venting outside casing

 

 

 

Vent Extension Kit

KGAVE0101DNH

Downflow, through casing vent extension

 

 

 

Chimney Adapter Kit

KGACA02014FC

Masonry chimney adapter 4” (102 mm)

 

 

KGACA02015FC

Masonry chimney adapter 5” (127 mm)

 

 

 

 

Natural--- to--- Propane Conversion Kit

KGANP4601ALL

Gas conversion natural to propane all

 

 

 

Propane--- to--- Natural Conversion Kit

KGAPN3901ALL

Gas conversion propane to natural all

 

 

 

Label Kit

KGALB0101KIT

Downflow orientation label replacement

 

 

 

**ECM Motor Simulator

KGASD0301FMS

ECM blower and inducer simulator --- variable speed units

 

 

 

**Advanced Product Monitor

KGAFP0301APM

PC software and hardware for Troubleshooting variable speed units

*Not for ECM or variable---speed ECM models

**Variable---speed ECM models only

312AAV

55

Image 55
Contents Service and Maintenance Procedures 312AAV CUT Hazard Safety ConsiderationsIntroduction Furnace Reliability HazardClearances to Combustibles Codes and Standards Electrostatic Discharge ESD Precautions ProcedureGeneral LocationCarbon Monoxide Poisoning and Unit Damage Hazard Property Damage Hazard AIR for Combustion VentilationFIRE, Injury or Death Hazard Fire HazardCarbon Monoxide Poisoning Hazard Furnace Corrosion HazardOutdoor Combustion Air Method Air for Combustion, Ventilation, and Dilution for Outdoors Upflow Installation InstallationSuspended Furnace Support Downflow InstallationHorizontal Installation FIRE, EXPLOSION, and Carbon Monoxide Poisoning HazardRoll-Out Protection Platform Furnace SupportDuct Flanges Opening dimensions In. mmHorizontal Unit Suspension Ductwork Acoustical Treatment Supply Air Connections Filter Arrangement Carbon Monoxide Poisoning HazardAIR Ducts General RequirementsFurnace Air Delivery CFM With FilterSpeed External Static Pressure IN. W.C Size Inlet GAS Piping Fire or Explosion Hazard Air Delivery CFM With Filter*Downflow Furnaces Return Air ConnectionsUpflow Return Air Configurations and Restrictions Furnace Damage Hazard Maximum Capacity of PipeFurnace MAY not Operate Hazard WiringElectrical Shock and Fire Hazard Electrical Connections Electrical Shock HazardElectrical Box on Furnace Casing Side. See Fig Electrical DataBOX Relocation Electrical Connection to J-BOXBX. Cable Installation in Furnace J-BOX Power Cord Installation in Furnace J-BOXTwo-Stage Furnace with Two-Speed Air Conditioner For Figures Venting AccessoriesMasonry Chimney Requirements General Venting RequirementsChimney Inspection Chart Internal Area of Chimney Appliance Application RequirementsVent Height Additional Venting Requirements Upflow Application-Vent Elbow UpDownflow Application-Vent Elbow Up then Left Horizontal Left Application Vent Elbow Left Furnace Vent Venting Notes forDiameter Vent Height Orientation INPUTBTUH/HR General START-UP, ADJUSTMENT, and Safety CheckBurn Hazard Fire and Explosion Hazard Start-Up ProceduresAdjustments Stage Furnace Setup Switch DescriptionRedundant Automatic Gas Control Valve Altitude Derate Multiplier for U.S.AOrifice Hole Furnace Overheating Hazard Gas Rate cu ft. /hrSeconds Size of Test Dial For Revolution Color Speed AS Shipped Speed SelectionDesired Heating Mode Setup Switch Blower OFF Delay SEC Check Safety ControlsChecklist Stage Furnace Blower OFF delay Setup SwitchA10184 A10184A A10185 A10185A Introduction Service and Maintenance ProceduresCarbon Monoxide Poisoning and Fire Hazard Care and MaintenanceWiring Diagram Filter Size Information In. / Mm Cleaning AND/OR Replacing AIR FilterBlower Motor and Wheel Electrical Shock Hazard Igniter Position-Side View Cleaning Heat ExchangerIgniter Position-Top View Sequence of Operation312AAV Thermidistat Mode Single-Stage Thermostat and Two-Speed Cooling Adaptive ModeSingle-Speed Cooling Troubleshooting Wiring DiagramsContinuous Blower Mode Troubleshooting Guide 2-Speed KitAdapter Chimneyin Usedswitch Shutoffvent Blocked Description Part Number Accessory ListParts Replacement Information Guide

312AAV/JAV specifications

The Bryant 312AAV/JAV is a prominent member of Bryant's series of high-efficiency air conditioning units, known for its reliability and advanced technology. Designed for residential and light commercial applications, this model combines exceptional performance with energy-efficient operation, making it a favorite among homeowners and builders alike.

One of the standout features of the 312AAV/JAV is its high SEER (Seasonal Energy Efficiency Ratio) rating, which allows users to enjoy significant savings on their energy bills. With a focus on energy efficiency, this unit minimizes electricity consumption while providing effective cooling throughout the hottest months. Its two-stage compressor technology not only enhances energy savings but also ensures consistent comfort by adjusting its operation to match the specific cooling needs of the space.

The Bryant 312AAV/JAV is equipped with Wi-Fi connectivity capabilities, allowing homeowners to control their cooling system remotely through a smartphone app. This feature adds a layer of convenience, enabling users to adjust settings, receive alerts, and track energy usage for optimal management of their home environment. Additionally, the unit’s compatibility with Smart Thermostats enhances its efficiency, facilitating further integration into a modern smart home setup.

Built for durability, the Bryant 312AAV/JAV features a robust construction that includes a galvanized steel cabinet designed to withstand harsh weather conditions. The rust-resistant finish not only prolongs the life of the unit but also ensures it maintains a sleek, attractive appearance. Quiet operation is another hallmark of this model; it operates at a low noise level, providing comfort without disruptive sound.

Moreover, this model employs environmentally friendly refrigerants, aligning with modern standards for eco-friendly cooling solutions. The 312AAV/JAV is designed with filters that provide superior air quality by effectively capturing dust and allergens, contributing to a healthier indoor environment.

In summary, the Bryant 312AAV/JAV air conditioning unit represents a blend of efficiency, technology, and durability. With its impressive energy-saving capabilities, smart connectivity, silent operation, and high-quality construction, it stands out as a top choice for those seeking reliable cooling solutions for their homes or light commercial settings. Whether for new installations or replacements, the 312AAV/JAV is designed to deliver exceptional performance while prioritizing comfort and sustainability.