Bryant 312AAV/JAV instruction manual Accessories, Venting

Page 25

ACCESSORIES

1.Electronic Air Cleaner (EAC)

Connect an accessory Electronic Air Cleaner (if used) us- ing 1/4-in female quick connect terminals to the two male 1/4-in quick-connect terminals on the control board marked EAC-1 and EAC-2. The terminals are rated for 115VAC, 1.0 amps maximum and are energized during blower motor operation. (See Fig. 33.)

2.Humidifier (HUM)

Connect an accessory 24 VAC, 0.5 amp. maximum hu- midifier (if used) to the 1/4-in male quick-connect HUM terminal and COM-24V screw terminal on the control board thermostat strip. The HUM terminal is energized when gas valve relay (GVR) is energized. (See Fig. 33.)

NOTE: A field-supplied, 115-v controlled relay connected to EAC terminals may be added if humidifier operation is desired during blower operation.

NOTE: DO NOT connect furnace control HUM terminal to HUM (humidifier) terminal on Thermidistat, Zone Controller or similar device. See Thermidistatt, Zone Controller, thermostat, or controller manufacturer’s instructions for proper connection.

VENTING

The furnace shall be connected to a listed factory built chimney or vent or a clay-tile lined masonry or concrete chimney. Venting into an unlined masonry chimney or concrete chimney is prohibited. When an existing Category I furnace is removed or replaced, the original venting system may no longer be sized to properly vent the attached appliances. An improperly sized Category I venting system could cause the formation of condensate in the furnace and vent, leakage of condensate and combustion products, and spillage of combustion products into the living space.

SETUP SWITCHES

TWINNING AND/OR

LOW-HEAT ONLY AND

COMPONENT TEST

BLOWER OFF-DELAY

TERMINAL

ACRDJ - AIR CONDITIONING

RELAY DISABLE JUMPER

312AAV

24-V-THERMOSTAT

TERMINALS

HUMIDIFIER TERMINAL (24-VAC 0.5 AMP MAX.)

3-AMP FUSE

LED OPERATION & DIAGNOSTIC LIGHT

115-VAC (L2) NEUTRAL

CONNECTIONS

HI HEAT

LO HEAT

W2

OFF

OFF

12 ON

 

LHT

 

 

Y1

DLY

 

3

 

 

DHUM

 

 

 

G

 

 

 

24V

 

 

 

TEST/TWIN

ACRDJ

COMWW1

 

 

 

HUM

PLT

 

 

 

 

 

 

Y/Y2

 

 

 

0.5-AMP024 VAC

 

 

 

 

 

 

R

 

 

 

 

 

 

 

FUSE 3-AMP

 

 

 

T

 

 

 

 

 

S AT SEC-1 SEC-2

 

E

 

U

 

 

 

 

 

S

 

 

 

L

 

 

 

 

 

 

D

 

C

 

 

PL1

E

 

 

 

 

 

 

O

 

 

 

 

EAC-2 NEUTRAL-L2

 

 

BLW

 

 

1

BHI/LOR

 

 

 

 

BHT/CLR

HI HEAT

 

 

 

 

 

 

LO

 

 

 

COOL

 

1-AMP@115 VAC

HEAT

SPARE-1

SPARE-2

EAC-1

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PL3

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

BLWR

 

 

 

 

 

 

 

 

 

 

 

 

 

IDR

 

 

HSIR

 

 

 

IDM

IHI/LOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1

1

 

 

 

 

 

 

 

 

 

 

 

 

PL2

 

 

 

 

 

 

 

 

 

PR-1

 

 

 

 

 

 

 

 

 

 

 

 

HSI

 

HI LO

 

 

 

 

 

 

 

 

 

 

 

TRANSFORMER 24-VAC

CONNECTIONS

PL1 - LOW VOLTAGE MAIN HARNESS CONNECTOR

PL3

 

SPARE-1

115-VAC (L1) LINE

PL2 - HOT SURFACE

 

SPARE-2 COOL

BLOWER SPEED

VOLTAGE CONNECTION

IGNITER & INDUCER

SELECTION TERMINALS

 

MOTOR CONNECTOR

EAC-1 TERMINAL

(115-VAC 1.0 AMP MAX.)

A02017

Fig. 33 - Furnace Control-PSC Blower Motor

25

Image 25
Contents Service and Maintenance Procedures 312AAV Introduction Safety ConsiderationsFurnace Reliability Hazard CUT HazardClearances to Combustibles Codes and Standards Electrostatic Discharge ESD Precautions ProcedureGeneral LocationCarbon Monoxide Poisoning and Unit Damage Hazard FIRE, Injury or Death Hazard AIR for Combustion VentilationFire Hazard Property Damage HazardCarbon Monoxide Poisoning Hazard Furnace Corrosion HazardOutdoor Combustion Air Method Air for Combustion, Ventilation, and Dilution for Outdoors Upflow Installation InstallationHorizontal Installation Downflow InstallationFIRE, EXPLOSION, and Carbon Monoxide Poisoning Hazard Suspended Furnace SupportRoll-Out Protection Platform Furnace SupportDuct Flanges Opening dimensions In. mmHorizontal Unit Suspension AIR Ducts Filter Arrangement Carbon Monoxide Poisoning HazardGeneral Requirements Ductwork Acoustical Treatment Supply Air ConnectionsFurnace Air Delivery CFM With FilterSpeed External Static Pressure IN. W.C Size Inlet Downflow Furnaces Air Delivery CFM With Filter*Return Air Connections GAS Piping Fire or Explosion HazardUpflow Return Air Configurations and Restrictions Furnace Damage Hazard Maximum Capacity of PipeElectrical Shock and Fire Hazard WiringElectrical Connections Electrical Shock Hazard Furnace MAY not Operate HazardBOX Relocation Electrical DataElectrical Connection to J-BOX Electrical Box on Furnace Casing Side. See FigBX. Cable Installation in Furnace J-BOX Power Cord Installation in Furnace J-BOXTwo-Stage Furnace with Two-Speed Air Conditioner For Figures Venting AccessoriesMasonry Chimney Requirements General Venting RequirementsChimney Inspection Chart Internal Area of Chimney Appliance Application RequirementsVent Height Additional Venting Requirements Upflow Application-Vent Elbow UpDownflow Application-Vent Elbow Up then Left Horizontal Left Application Vent Elbow Left Furnace Vent Venting Notes forDiameter Vent Height Orientation INPUTBTUH/HR General START-UP, ADJUSTMENT, and Safety CheckBurn Hazard Adjustments Start-Up ProceduresStage Furnace Setup Switch Description Fire and Explosion HazardRedundant Automatic Gas Control Valve Altitude Derate Multiplier for U.S.AOrifice Hole Furnace Overheating Hazard Gas Rate cu ft. /hrSeconds Size of Test Dial For Revolution Color Speed AS Shipped Speed SelectionChecklist Check Safety ControlsStage Furnace Blower OFF delay Setup Switch Desired Heating Mode Setup Switch Blower OFF Delay SECA10184 A10184A A10185 A10185A Introduction Service and Maintenance ProceduresCarbon Monoxide Poisoning and Fire Hazard Care and MaintenanceWiring Diagram Filter Size Information In. / Mm Cleaning AND/OR Replacing AIR FilterBlower Motor and Wheel Electrical Shock Hazard Igniter Position-Side View Cleaning Heat ExchangerIgniter Position-Top View Sequence of Operation312AAV Thermidistat Mode Single-Stage Thermostat and Two-Speed Cooling Adaptive ModeSingle-Speed Cooling Troubleshooting Wiring DiagramsContinuous Blower Mode Troubleshooting Guide 2-Speed KitAdapter Chimneyin Usedswitch Shutoffvent Blocked Description Part Number Accessory ListParts Replacement Information Guide

312AAV/JAV specifications

The Bryant 312AAV/JAV is a prominent member of Bryant's series of high-efficiency air conditioning units, known for its reliability and advanced technology. Designed for residential and light commercial applications, this model combines exceptional performance with energy-efficient operation, making it a favorite among homeowners and builders alike.

One of the standout features of the 312AAV/JAV is its high SEER (Seasonal Energy Efficiency Ratio) rating, which allows users to enjoy significant savings on their energy bills. With a focus on energy efficiency, this unit minimizes electricity consumption while providing effective cooling throughout the hottest months. Its two-stage compressor technology not only enhances energy savings but also ensures consistent comfort by adjusting its operation to match the specific cooling needs of the space.

The Bryant 312AAV/JAV is equipped with Wi-Fi connectivity capabilities, allowing homeowners to control their cooling system remotely through a smartphone app. This feature adds a layer of convenience, enabling users to adjust settings, receive alerts, and track energy usage for optimal management of their home environment. Additionally, the unit’s compatibility with Smart Thermostats enhances its efficiency, facilitating further integration into a modern smart home setup.

Built for durability, the Bryant 312AAV/JAV features a robust construction that includes a galvanized steel cabinet designed to withstand harsh weather conditions. The rust-resistant finish not only prolongs the life of the unit but also ensures it maintains a sleek, attractive appearance. Quiet operation is another hallmark of this model; it operates at a low noise level, providing comfort without disruptive sound.

Moreover, this model employs environmentally friendly refrigerants, aligning with modern standards for eco-friendly cooling solutions. The 312AAV/JAV is designed with filters that provide superior air quality by effectively capturing dust and allergens, contributing to a healthier indoor environment.

In summary, the Bryant 312AAV/JAV air conditioning unit represents a blend of efficiency, technology, and durability. With its impressive energy-saving capabilities, smart connectivity, silent operation, and high-quality construction, it stands out as a top choice for those seeking reliable cooling solutions for their homes or light commercial settings. Whether for new installations or replacements, the 312AAV/JAV is designed to deliver exceptional performance while prioritizing comfort and sustainability.