Emerson 3000 installation manual Factory Piping Field Piping

Page 35

Air-Cooled Models—Self-Contained Compressor

Figure 15 General arrangement—Air-cooled models with fan speed control

Inverted Trap * on discharge line to extend above base of coil by a minimum of 7-1/2" (190mm)

Condenser

Coil

Schrader

Valve

Fusible

Plug

Traps* every

 

 

25 ft. (7.6m)

 

 

of rise

 

Hot Gas

 

 

 

 

Bypass

 

 

Valve

 

Liquid Return Solenoid

 

 

Valves

 

Shutoff*

Sight

 

Glass

 

Valve

 

 

Filter

Dryer

Evaporator

Coil

Expansion

Valve

Sensing

Bulb

External Equalizers

Hot Gas

Bypass

Check Valve

Hot Gas

Discharge

Service

Valves

Scroll

Compressor

FACTORY PIPING

FIELD PIPING

*Components are not supplied by Liebert but are recommended for proper circuit operation and maintenance.

DPN000349

Rev. 3

29

Image 35
Contents Liebert Challenger 3000 with iCOM Page Table of Contents R407C Refrigerant Chilled Water ModelsSplit System Models Figures Tables Important Safety Instructions Page System Descriptions Water-Cooled Split SystemsProp Fan Air-Cooled Centrifugal Fan Air-CooledEquipment Handling Room PreparationEquipment Inspection Location ConsiderationsModel Lb kg Unit net weightHandling With Skid Removal of SkidUpflow BU cabinet dimensions Floor Cutout Dimensions Piping connection size Piping ConsiderationsDrain Line Piping Outlet Locations Piping connections for air-cooled units Upflow models Installation Applicable to all Models Installation Applicable to all Models Installation Applicable to all Models Installation Applicable to all Models Installation Applicable to all Models Installation Applicable to all Models Humidifier Supply Water-Optional Infrared Facility Fluid and Piping MaintenanceElectrical Connections Terminal Block for customer connections Downflow Models with Liebert iCOM Upflow Models with Liebert iCOMDucted Applications Plenum InstallationBalancing the Air Distribution Under-Floor Discharge SystemsChecklist for Completed Installation Low Voltage Condenser LocationLine Voltage Air-cooled condenser statistics Recommended line sizes OD copper inches Refrigerant PipingIndoor unit refrigerant charge lb kg Fan Speed Control SystemsVariable Fan Speed Control Piping Equivalent lengths feet for various pipe fittingsVariable Fan Speed Control Materials Supplied Variable Fan Speed Charging Fan speed suction pressure transducer settingsFactory Piping Field Piping Factory Piping Liebert Lee-Temp Controlled Materials Supplied Lee-Temp Leak Check and Evacuation ProcedureLiebert Lee-Temp Piping 407C Lee-Temp suction pressure transducer settingsLee-Temp Charging Lee-Temp Receiver Refrigerant LevelFactory Piping Optional Piping Pressure Relief Condenser Factory Piping Field Piping Factory Piping Field Piping Water Regulating Valve AdjustmentControl Refrigerant control settings psi kPaMotorized Ball Valve-Digital Scroll Compressors Manual FlushingManual Control StartupLocation Pump and Drycooler Drycooler InstallationDrycooler Location General Guidelines Glycol PipingDry Bulb Wet Bulb Relative Dew Point Humidity Room dew point temperaturesPreparing the System for Filling Volume in standard Type L copper pipingFilling Instructions Expansion Tanks, Fluid Relief Valves and Other DevicesGlycol Solutions @ 50F 10C Filling the SystemEthylene glycol concentrations 483mm 1097mm For expansion tank dimensions, see on43-3/16 43-9/16 110 5mm See Note 30-1/4Pump Pump Suction Pump Discharge Connection Mounting hole dimensional dataDrycooler data Glycol pump dataField Piping General arrangement-Glycol-cooled models with digital scroll Field Piping Factorypiping Field Piping Motor Ball Valve-Digital Scroll Compressors Testing Valve FunctionGlycol Regulating Valve Chilled Water Models WAY Valve Water/Glycol-Cooled Condensing Units Air-Cooled Condensing UnitsRefrigerant Loop Recommended refrigerant lines R407C sizes OD copper Unit refrigerant chargeLine charges refrigerant per 100 ft m of Type L copper tube Model Line Size Coupling Torque Tons OD Cu, Lb-ft Quick Connect FittingsLine coupling sizes Outdoor Air-Cooled Condensing Units Unit Dimensions See TablePFCZ42A-L PFCZ41A-L See Table Outdoor air-cooled condensing unit-top air discharge models152 Piping and electrical connections top air discharge36-1/4 38-1/2 Ton High Ambient Ton Quiet-Line Field-supplied unit disconnect switchIndoor centrifugal condensing unit Installing the Indoor Condensing UnitModel Net Weight 60 Hz 50 Hz Lb kg MC40A MC39A Centrifugal Air-Cooled Condensing UnitsAirflow CFM CMH DuctingPiping Connections Mod Wire connections from evaporatorDPN000207 Rev0Ton centrifugal air-cooled condensing unit dimensional data AIR Cooled Water Cooled Regulating Valve Water and Glycol-Cooled Condensing UnitsPiping Considerations Condenser Water RequirementsTon water/glycol-cooled condensing unit Glycol Systems24V GND Ton water/glycol-cooled condensing unit dimensional data WATER/GLYCOL R407C Refrigerant Temperature Gauge Pressure Psig KPaExample Temperature Pressure Gauge Psig KPaCalculating Subcooling R407C Refrigerant R407C Refrigerant Page Te r Ys t Ne tIti Ti n That
Related manuals
Manual 88 pages 63.05 Kb Manual 60 pages 24.1 Kb Manual 32 pages 13.16 Kb Manual 22 pages 3.64 Kb Manual 76 pages 17.32 Kb Manual 184 pages 52.9 Kb

3000 specifications

The Emerson 3000 is a cutting-edge control system designed to enhance the efficiency, reliability, and precision of industrial operations. Employed across various sectors such as oil and gas, pharmaceutical, food and beverage, and power generation, the Emerson 3000 has gained recognition for its robustness and versatility.

One of the main features of the Emerson 3000 is its advanced process control capability. With integrated control algorithms, it can optimize complex processes in real-time, resulting in significant improvements in production rates and reduced operational costs. The system's predictive analytics capabilities enable operators to anticipate equipment failures and maintenance needs, allowing for proactive management and minimizing downtime.

The Emerson 3000 features a modular architecture, providing flexibility for scaling and customization. Operators can easily tailor the system to fit specific application needs, whether it requires additional control loops or integration with other systems. This adaptability is particularly beneficial for facilities planning for future expansions or modifications.

Another technology highlight of the Emerson 3000 is its seamless integration with the latest Internet of Things (IoT) advancements. The system is designed to communicate effectively with a variety of smart devices and sensors, harnessing data to create insightful analytics that drive operational excellence. This connectivity empowers businesses to leverage big data for improved decision-making and increased agility.

Additionally, the Emerson 3000 incorporates state-of-the-art cybersecurity measures to safeguard critical data and operations. With built-in security protocols and regular updates, the system protects against emerging cyber threats, ensuring the integrity of the control network.

User experience is also a focal point of the Emerson 3000. The intuitive graphical user interface presents complex data in a user-friendly format, making it easier for operators to monitor system performance and respond to alerts quickly. This ease of use contributes to enhanced safety and operational efficiency.

In summary, the Emerson 3000 represents a fusion of advanced process control, modular design, IoT connectivity, robust cybersecurity, and user-centric interface, making it an ideal choice for industries seeking to enhance their operational performance while adapting to ever-evolving technological landscapes.