SCOTSMAN WOOD FURNACE – INSTRUCTION MANUAL

2.6.1FREE-STANDING (Fig S101-9)

The KERR SCOTSMAN Wood Furnace in the free standing (stand-alone) system, is the sole source of central heating using an optional blower box kit to circulate the air. In this system connect the ductwork, as you would for any conventional warm air heating system except you use increased clearances. The return air ducts are connected to the blower box, which may be located on either side of the furnace.

NOTE: With the optional blower, this furnace is not to be connected to ductwork that is still connected to another furnace.

2.6.2ADD-ON (Fig S101-7, Fig S101-8)

The KERR Wood Furnace may be installed very satisfactorily in conjunction with another furnace as tested by ETLM under standard 78-1 and CSA under standard B365/1981.

In this installation the wood furnace is connected downstream in series with a new or the existing oil furnace. The blower from the existing furnace provides the air circulation. The SCOTSMAN may only be added in series downstream from an oil furnace having an input rating (on original nameplate) of between 0.85 and 1.50 gph (US) or SI equivalent.

For oil furnaces having multi-speed blowers with continuous circulation capability.

Add-on furnaces such as the Kerr Scotty SS can be installed with oil fired warm air furnaces such as the Kerr KD Gemini that have continuous blower circulation capability. A relay must be used if the furnace is to maintain the continuous circulation feature. The wiring diagram for this installation is Fig. S101 – 7.

Disconnect Low Speed Circulation Fan Switch if Optional Relay is not used. Fig S101 - 8.

Disconnecting the circulation fan low speed switch.

If the red wire from the circulation fan switch, in the furnace wiring box, were disconnected from the yellow wire leading to the blower compartment and both, red and yellow wires marretted off then there would be no need for the switching relay (Honeywell R4222D 1013 or equiv.).

In that case the two blue wires would marrette together at location “A” of “Add-On Wiring” diagram, and provide power to the blower on high speed (black wire). The two blue wires being 1.) Wood fan “ON” control and, 2.) Oil fan “ON” control.

Also 120 Volts can be fed back through any unused wire from the blower. All unused wires should be marretted off.

Low Speed Switching Relay (This is an optional part) Fig S101 – 7.

The Honeywell (R4222D 1013 or equiv.) relay is to prevent power from being fed to the blower motor on two motor windings at the same time.

The red wire from the circulation fan switch (Low Speed) on the oil furnace.

Scotsman

13

Oct-06

Image 14
Contents Scotsman Wood Furnace Table of Contents Specifications Operating Instructions Introduction WOOD-BURNINGCase a Serious Creosote Fire Begins Storage of WoodCreosote Cleaning Procedure MaintenanceCleaning Fig S101-10 Maximum SOLID-FUEL ChargeControls SafetyServicing Disposal of AshesElectrical Power Failure Fig S101-3 Applicable Standards Homeowner ChecklistInstallation Instructions Introduction to Installers Uncrating Locating the Furnace Fig S101-1, Fig S101-4Combustion AIR Supply Flue Pipe & ChimneyScotsman Warm AIR Duct & Plenum Clearances Minimum safety clearances to combustibles areClearances Fig S101-1 ADD-ON Fig S101-7, Fig S101-8 Disconnecting the circulation fan low speed switchLow Speed Switching Relay This is an optional part Fig S101 Low Speed Switching Relay Installation Instructions Items requiredScotsman Control System Fig S101-5 T822 Room Thermostat Wood FurnaceInstallers Final Checklist Addendum Page Page Page Page Page Page Page Page Page Page Page Page Page Terms and Conditions of Warranty Year Warranty

DB-101 specifications

The Scotsman Ice DB-101 is a state-of-the-art ice maker designed for commercial use, catering to restaurants, bars, hotels, and other hospitality venues that require a reliable supply of high-quality ice. This model is highly regarded for its efficiency, power, and innovative technology, making it an ideal choice for businesses looking to enhance their ice production capabilities.

One of the standout features of the Scotsman Ice DB-101 is its ability to produce a significant amount of ice. This ice machine can produce up to 105 pounds of ice per day, depending on ambient conditions, making it suitable for establishments with high ice demands. The unit is designed to create individual half-dice ice cubes, which not only chill beverages efficiently but also provide a visually appealing presentation.

The technology behind the Scotsman Ice DB-101 is impressive. It employs a powerful self-diagnostic control system that allows for easy monitoring of the machine's performance. This feature minimizes downtime by promptly alerting users to potential issues, ensuring that the ice production remains uninterrupted. Additionally, the unit boasts a compact design that fits seamlessly into various spaces while providing substantial ice-making capacity.

Energy efficiency is another hallmark of the Scotsman Ice DB-101. The machine follows eco-friendly standards, consuming less power compared to other models in its class. This feature not only helps in reducing energy bills but also contributes to sustainability efforts within the hospitality industry.

Other notable characteristics include a durable stainless-steel construction that ensures longevity and resistance to corrosion, making it suitable for busy environments. The user-friendly interface allows for easy operation, and the automatic rinse cycle feature maintains ice purity by preventing mineral buildup and ensuring optimal taste.

The Scotsman Ice DB-101 also offers a versatile water source option, compatible with both filtered and standard water, ensuring users can maintain ice quality as per their requirements.

In summary, the Scotsman Ice DB-101 is a top-tier ice machine that combines efficiency, durability, and advanced technology, making it a valued investment for any commercial establishment that relies on a consistent supply of ice for its operations. Its capacity, energy efficiency, and user-friendly design make it a notable choice for industry professionals.