Lennox Hearth EN03-VDLPM Install Firestop/Spacer at exterior wall, Mm as shown in Figure

Page 17

If the terminus of the last section is not within this distance, use the telescopic vent section SV4.5LA, as the last vent section. For wall thicknesses greater than that shown in Figure 28, refer to Table 3 on page 18. This table lists the additional venting components needed (in addition to the termination and adapter) for a particular range of wall thicknesses.

M. Attach termination adapter - Attach the adapter (SV4.5RCH - provided with the termi- nation) to the vent section or telescoping vent section), elbow as shown in Figure 27 in the same manner as any SV4.5 vent component (refer to Step F).

N. Install Firestop/Spacer at exterior wall -

When using the square termination, install the SV4.5HF (Secure Vent) or SF4.5HF (Se- cure Flex) Firestop/Spacer over the open- ing at the exterior side of the framing (long side up) as shown in Figure 27, and fasten into place. Ensure 5" clearance is main- tained by framing above the vent run for MPLDV35/40/45 when center line of the run is lower than 48" (12119 mm) above

Firestop/Spacer provided with the termination shown on the exterior side of the wall. It may also be

installed on the interior side.SV4.5 HT-2Termination

 

**7"

10-1/2"

 

(178)

**12-1/8"

(267 mm)

 

(308 mm)

 

 

5-1/8"

(130 mm)

**3” (76 mm) for MPLDV30/35

6 to 48 inch

 

1"

Vent Section,

 

 

(25.4 mm)

Telescopic vent

 

section on Elbow

 

 

 

Note: Centerline of Vent Piping is

 

NOT the Same as the Centerline of

Adapter

the Frame Opening.

 

SV4.5RCH

 

See Figure 9 on page 8

 

 

for Min. Distance to Base

**Increase these dimensions by 2” (51mm) for MPLDV35/40/45

of Appliance.

 

with horizontal vent runs with center lines lower than 48”

Base of Appliance

(1219mm) above the fireplace for wrapper surface.

Figure 27 Installing the Square Horizontal Termination (SV4.5HT-2)

the fireplace top wrapper surface.

(The Firestop/Spacer may also be installed over the opening at the interior side of the framing.)

O. Install the desired termination -

1. Install the square termination (SV4.5HT-2)-

For the last step , from outside the exterior wall,

slide the collars of the termination onto the

*Use silicone caulking to seal the top and sides of the termination, up to the underlayment, stucco, or masonry wall surface.

Siding

*Caulk

Interior Surface of

Finished Wall

Maximum Extent of Vent Run Sections Relative to Exterior Surface of Framing

Last Vent Section. Use T e l e s c o p i c V e n t Section (SV4.5LA), If Necessary

Maximum wall thickness 10 in.(254 mm)**

Exterior Surface of Siding

Exterior Surface of

Framing

6 in. to 9-1/4 in. (152 to 235 mm)**

SV4.5HT-2

adapter (the outer over the outer and the inner

inside the inner) until the termination seats against

the exterior wall surface to which it will be

attached. Orient the housing of the termination

with the arrow pointed upwards. Secure the

termination to the exterior wall. The horizontal

termination must not be recessed into the

exterior wall or siding by more than the 1-1/4"

(32 mm) as shown in Figure 28.

*Caulk

SV4.5HT-2 Square Termination

Adapter

SV4.5RCH

Stucco

**For thicknesses greater

than 10”, see Table 3.

Square Termination

1-1/4" Maximum Recess of

Square Termination into

Exterior Finishing Material

SVHRK Snorkel Cap –The snorkel cap is de- signed to be fitted into a basement window box. The SVHRK cap is for use with flex vent. The vertical distance between the inlet and outlet of the cap is 28 in. (711 mm). pipe.

IMPORTANT: The vent termination is hot while in operation and for a period of time following use of the fireplace. To prevent contact with hot surfaces, we recommend the use of a Termination Guard. This can be purchased at your local dealer.

Venting Connection and Exterior Wall Recessing of the

Horizontal Square Termination (SV4.5HT-2).

Figure 28

Horizontal terminations have been designed to perform in a wide range of weather conditions. Our terminations meet or exceed industry standards.

When selecting the locations of your horizontal terminations, do not place the termination where water from eaves and adjoining rooflines may create a heavy flow of cascading water onto the termination cap. If the cap must be placed where the possibility of cascading water exists, it is the responsibility of the builder to direct the water away from the termination cap by using gutters or other means.

Take care to carefully follow the installation instructions for the termination, including the use of silicone caulking where required.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

17

Image 17
Contents MPLDV-35NM-2 OTL Report No -F-47-5Table of Contents All Models Millivolt And Electronic ModelsModel Orifice size Nat PropLocation Typical LocationsModel No Shelf Height inches mm Top Vent ApplicationAppliance and Vent Clearances Vertical Vent Termination ClearancesVent Termination Clearances Horizontal Vent Termination ClearancesDetailed Installation Steps Typical Installation SequenceRouting GAS Line Horizontal Vent Termination ClearancesMeter/regulator assembly Canadian Installation US Installation= Clearance to service regulator vent outlet Feet 91cm Inches 30cm903 1035 419 965 Model No1030 1162 419 1092 FramingModel No Vertical Termination Systems Roof Install the Vent SystemThese fireplaces must be vented directly to the outside Vent Section Length Chart Connection 10 1/2 Min 267 mmVent / 45 Degree Starter Elbow Connection 10-1/2 267 mm Framing Dimensions for Roof Pitch12/12 10-1/2Support Vertical Vent FIGURES/TABLESBracket Ceiling Firestop/Spacer SV4.5VF Detail ViewPlan the vent run Horizontal Outside Wall Termination SystemInstall firestop/spacer at ceiling Typical Horizontal Vent InstallationFrame exterior wall opening Four incline channels on the collar refer to onInstall the desired termination Install Firestop/Spacer at exterior wallMm as shown in Figure Slide the collars of the termination ontoExterior Wall Thickness Horizontal Vent FIGURES/TABLESConnection Directly AT Appliance Connection not Directly AT ApplianceWall Wall Firestop/SpacerCeiling Firestop/Spacer SV4.5VF WallPull and extend the inner flexible vent pipe Install the Outer Flex PipePull and extend the outer flexible vent pipe Route Flex VentMillivolt Wiring See Figure Field WiringElectronic Wiring See Figure After the wiring is complete, replace the cover plateConnecting GAS Line Installing the Glass Door Installing the Glass Door and Optional HoodING Embers and Volcanic Stones MillivoltBurner Adjustment Burner AdjustmentsFinishing Requirements Wall DetailsMantel Clearances Installation AccessoriesCold Climate Insulation Cat. No. Model No. Description CatMillivolt Appliances .2 Installation CodeGAS Conversion Kits Model No Orifice size Natural Pilot Orifice Electronic Appliances Dexen Electronic ValvesPage Page West Taft Avenue Orange, CA 850,043M REV. F 09/2008